Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.21/11475 |
Resumo: | This paper presents a complete and detailed description of the fabrication and measurement of the electromagnetic properties of water-based semi-solid phantoms with emphasis on the analysis of the time evolution of the complex permittivity of several samples stored in different conditions. A known recipe for a 2/3 muscle equivalent phantom is used as test material, and the several phantom sample properties are measured with an in-house developed coaxial probe technique. It is shown that the storing condition is of paramount importance to extend the lifetime of a given phantom. This behavior stems from the way the storing condition affects the water evaporation rate of the sample. In particular, while an unprotected sample can preserve its electromagnetic properties only for a few days, a very well-sealed one can last at least up to a year. |
id |
RCAP_10870133bf1f5a93889f93fd04623264 |
---|---|
oai_identifier_str |
oai:repositorio.ipl.pt:10400.21/11475 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantomsBANPhysical phantom2/3 muscleCoaxial probe technique;Complex permittivity measurementThis paper presents a complete and detailed description of the fabrication and measurement of the electromagnetic properties of water-based semi-solid phantoms with emphasis on the analysis of the time evolution of the complex permittivity of several samples stored in different conditions. A known recipe for a 2/3 muscle equivalent phantom is used as test material, and the several phantom sample properties are measured with an in-house developed coaxial probe technique. It is shown that the storing condition is of paramount importance to extend the lifetime of a given phantom. This behavior stems from the way the storing condition affects the water evaporation rate of the sample. In particular, while an unprotected sample can preserve its electromagnetic properties only for a few days, a very well-sealed one can last at least up to a year.MDPIRCIPLMendes, CarlosPeixeiro, Custódio2020-04-17T18:34:00Z2019-102019-10-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/11475engMENDES, Carlos; PEIXEIRO, Custódio – Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms. Sensors. ISSN 1424-8220. Vol. 19, N.º 19 (2019), pp. 1-211424-822010.3390/s19194298info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T10:02:46Zoai:repositorio.ipl.pt:10400.21/11475Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:19:43.366466Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms |
title |
Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms |
spellingShingle |
Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms Mendes, Carlos BAN Physical phantom 2/3 muscle Coaxial probe technique; Complex permittivity measurement |
title_short |
Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms |
title_full |
Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms |
title_fullStr |
Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms |
title_full_unstemmed |
Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms |
title_sort |
Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms |
author |
Mendes, Carlos |
author_facet |
Mendes, Carlos Peixeiro, Custódio |
author_role |
author |
author2 |
Peixeiro, Custódio |
author2_role |
author |
dc.contributor.none.fl_str_mv |
RCIPL |
dc.contributor.author.fl_str_mv |
Mendes, Carlos Peixeiro, Custódio |
dc.subject.por.fl_str_mv |
BAN Physical phantom 2/3 muscle Coaxial probe technique; Complex permittivity measurement |
topic |
BAN Physical phantom 2/3 muscle Coaxial probe technique; Complex permittivity measurement |
description |
This paper presents a complete and detailed description of the fabrication and measurement of the electromagnetic properties of water-based semi-solid phantoms with emphasis on the analysis of the time evolution of the complex permittivity of several samples stored in different conditions. A known recipe for a 2/3 muscle equivalent phantom is used as test material, and the several phantom sample properties are measured with an in-house developed coaxial probe technique. It is shown that the storing condition is of paramount importance to extend the lifetime of a given phantom. This behavior stems from the way the storing condition affects the water evaporation rate of the sample. In particular, while an unprotected sample can preserve its electromagnetic properties only for a few days, a very well-sealed one can last at least up to a year. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-10 2019-10-01T00:00:00Z 2020-04-17T18:34:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.21/11475 |
url |
http://hdl.handle.net/10400.21/11475 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
MENDES, Carlos; PEIXEIRO, Custódio – Fabrication, measurement and time decay of the electromagnetic properties of semi-solid water-based phantoms. Sensors. ISSN 1424-8220. Vol. 19, N.º 19 (2019), pp. 1-21 1424-8220 10.3390/s19194298 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
MDPI |
publisher.none.fl_str_mv |
MDPI |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133464768806912 |