Resumo: | Neonatal Intensive Care Unit (NICU) noise may be stressful to preterm infants. This research evaluated the newborns exposure to noise during several health care activities of two NICU. The measurements of the equivalent continuous A-weighted sound pressure level and peak sound pressure level were carried were performed with a sound level meter, as close as possible of the newborn. The results showed that sound pressure levels were excessive in all the evaluated tasks, exceeding international guidelines. The levels ranged between 46.6 dBA to 74.6 dBA. There is a need for more research in order to verify the effectiveness of specific strategies to reduce the impact of noise in NICU. |
id |
RCAP_1128f7e55059aa8aa484f0676852748c |
---|---|
oai_identifier_str |
oai:recipp.ipp.pt:10400.22/10256 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Newborns Safety at Neonatal Intensive Care Units: Are they Exposed to Excessive Noise during Routine Health Care Procedures?noisenicunewbornsinfantsNeonatal Intensive Care Unit (NICU) noise may be stressful to preterm infants. This research evaluated the newborns exposure to noise during several health care activities of two NICU. The measurements of the equivalent continuous A-weighted sound pressure level and peak sound pressure level were carried were performed with a sound level meter, as close as possible of the newborn. The results showed that sound pressure levels were excessive in all the evaluated tasks, exceeding international guidelines. The levels ranged between 46.6 dBA to 74.6 dBA. There is a need for more research in order to verify the effectiveness of specific strategies to reduce the impact of noise in NICU.Insight Medical PublishingRepositório Científico do Instituto Politécnico do PortoAlberto Alves Carvalhais, CarlosVieira Da Silva, ManuelaXavier, AnaSantos, Joana2017-09-11T13:55:08Z2017-082017-08-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/10256enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:51:48Zoai:recipp.ipp.pt:10400.22/10256Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:30:42.897562Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Newborns Safety at Neonatal Intensive Care Units: Are they Exposed to Excessive Noise during Routine Health Care Procedures? |
title |
Newborns Safety at Neonatal Intensive Care Units: Are they Exposed to Excessive Noise during Routine Health Care Procedures? |
spellingShingle |
Newborns Safety at Neonatal Intensive Care Units: Are they Exposed to Excessive Noise during Routine Health Care Procedures? Alberto Alves Carvalhais, Carlos noise nicu newborns infants |
title_short |
Newborns Safety at Neonatal Intensive Care Units: Are they Exposed to Excessive Noise during Routine Health Care Procedures? |
title_full |
Newborns Safety at Neonatal Intensive Care Units: Are they Exposed to Excessive Noise during Routine Health Care Procedures? |
title_fullStr |
Newborns Safety at Neonatal Intensive Care Units: Are they Exposed to Excessive Noise during Routine Health Care Procedures? |
title_full_unstemmed |
Newborns Safety at Neonatal Intensive Care Units: Are they Exposed to Excessive Noise during Routine Health Care Procedures? |
title_sort |
Newborns Safety at Neonatal Intensive Care Units: Are they Exposed to Excessive Noise during Routine Health Care Procedures? |
author |
Alberto Alves Carvalhais, Carlos |
author_facet |
Alberto Alves Carvalhais, Carlos Vieira Da Silva, Manuela Xavier, Ana Santos, Joana |
author_role |
author |
author2 |
Vieira Da Silva, Manuela Xavier, Ana Santos, Joana |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Repositório Científico do Instituto Politécnico do Porto |
dc.contributor.author.fl_str_mv |
Alberto Alves Carvalhais, Carlos Vieira Da Silva, Manuela Xavier, Ana Santos, Joana |
dc.subject.por.fl_str_mv |
noise nicu newborns infants |
topic |
noise nicu newborns infants |
description |
Neonatal Intensive Care Unit (NICU) noise may be stressful to preterm infants. This research evaluated the newborns exposure to noise during several health care activities of two NICU. The measurements of the equivalent continuous A-weighted sound pressure level and peak sound pressure level were carried were performed with a sound level meter, as close as possible of the newborn. The results showed that sound pressure levels were excessive in all the evaluated tasks, exceeding international guidelines. The levels ranged between 46.6 dBA to 74.6 dBA. There is a need for more research in order to verify the effectiveness of specific strategies to reduce the impact of noise in NICU. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-09-11T13:55:08Z 2017-08 2017-08-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.22/10256 |
url |
http://hdl.handle.net/10400.22/10256 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Insight Medical Publishing |
publisher.none.fl_str_mv |
Insight Medical Publishing |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1817550493204873216 |