Development of a ECG-Gated Equilibrium Angiocardiography System
Autor(a) principal: | |
---|---|
Data de Publicação: | 1999 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://proa.ua.pt/index.php/revdeti/article/view/18762 |
Resumo: | The equilibrium radionuclide angiocardiography is a powerful diagnosis technique for a non-invasive evaluation of the cardiac function. The red blood cellsare labelled using an intravenous injection of the radioactive tracer (99mTc). This method requires the use of a gamma camera and a data acquisition and processing system for the calculation of quantitative hemodynamic parameters describing the left ventricular function. The qualitative analysis of functional images generated from raw data further permits the evaluation of regional cardiac function. (...) |
id |
RCAP_165af1ef531367f360483064e16c98a6 |
---|---|
oai_identifier_str |
oai:proa.ua.pt:article/18762 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Development of a ECG-Gated Equilibrium Angiocardiography SystemDesenvolvimento de um sistema de angiocardiografia de equilíbrioThe equilibrium radionuclide angiocardiography is a powerful diagnosis technique for a non-invasive evaluation of the cardiac function. The red blood cellsare labelled using an intravenous injection of the radioactive tracer (99mTc). This method requires the use of a gamma camera and a data acquisition and processing system for the calculation of quantitative hemodynamic parameters describing the left ventricular function. The qualitative analysis of functional images generated from raw data further permits the evaluation of regional cardiac function. (...)A angiocardiografia de equilíbrio é um poderoso meio de diagnóstico que permite avaliar de forma não invasiva a função cardíaca. Através da injecção intravenosa de um traçador radioactivo (99m Tc) são marcados os glóbulos vermelhos. Este facto possibilita, com o auxílio de uma câmara de raios gama e de um computador, a obtenção de parâmetros hemodinâmicos quantitativos que caracterizam a função ventricular esquerda. Torna-se ainda possível avaliar regionalmente a função cardíaca mediante a criação de imagens funcionais e respectiva análise semiquantitativa. (...)UA Editora1999-01-01T00:00:00Zdoctoral thesisdoctoral thesisinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://proa.ua.pt/index.php/revdeti/article/view/18762oai:proa.ua.pt:article/18762Eletrónica e Telecomunicações; Vol 2 No 5 (1999); 578-579Eletrónica e Telecomunicações; vol. 2 n.º 5 (1999); 578-5792182-97721645-0493reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPporhttps://proa.ua.pt/index.php/revdeti/article/view/18762https://proa.ua.pt/index.php/revdeti/article/view/18762/13581https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessRafael, José AlbertoLima, J. J. P. deVeiga, E. Alte da2022-09-26T11:00:31Zoai:proa.ua.pt:article/18762Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:08:38.534456Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Development of a ECG-Gated Equilibrium Angiocardiography System Desenvolvimento de um sistema de angiocardiografia de equilíbrio |
title |
Development of a ECG-Gated Equilibrium Angiocardiography System |
spellingShingle |
Development of a ECG-Gated Equilibrium Angiocardiography System Rafael, José Alberto |
title_short |
Development of a ECG-Gated Equilibrium Angiocardiography System |
title_full |
Development of a ECG-Gated Equilibrium Angiocardiography System |
title_fullStr |
Development of a ECG-Gated Equilibrium Angiocardiography System |
title_full_unstemmed |
Development of a ECG-Gated Equilibrium Angiocardiography System |
title_sort |
Development of a ECG-Gated Equilibrium Angiocardiography System |
author |
Rafael, José Alberto |
author_facet |
Rafael, José Alberto Lima, J. J. P. de Veiga, E. Alte da |
author_role |
author |
author2 |
Lima, J. J. P. de Veiga, E. Alte da |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Rafael, José Alberto Lima, J. J. P. de Veiga, E. Alte da |
description |
The equilibrium radionuclide angiocardiography is a powerful diagnosis technique for a non-invasive evaluation of the cardiac function. The red blood cellsare labelled using an intravenous injection of the radioactive tracer (99mTc). This method requires the use of a gamma camera and a data acquisition and processing system for the calculation of quantitative hemodynamic parameters describing the left ventricular function. The qualitative analysis of functional images generated from raw data further permits the evaluation of regional cardiac function. (...) |
publishDate |
1999 |
dc.date.none.fl_str_mv |
1999-01-01T00:00:00Z |
dc.type.driver.fl_str_mv |
doctoral thesis doctoral thesis info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://proa.ua.pt/index.php/revdeti/article/view/18762 oai:proa.ua.pt:article/18762 |
url |
https://proa.ua.pt/index.php/revdeti/article/view/18762 |
identifier_str_mv |
oai:proa.ua.pt:article/18762 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://proa.ua.pt/index.php/revdeti/article/view/18762 https://proa.ua.pt/index.php/revdeti/article/view/18762/13581 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by/4.0/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
UA Editora |
publisher.none.fl_str_mv |
UA Editora |
dc.source.none.fl_str_mv |
Eletrónica e Telecomunicações; Vol 2 No 5 (1999); 578-579 Eletrónica e Telecomunicações; vol. 2 n.º 5 (1999); 578-579 2182-9772 1645-0493 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130543702409216 |