The effect of grid misalignment on the uniformity of response of gas proportional scintillation counters
Autor(a) principal: | |
---|---|
Data de Publicação: | 1997 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/12908 https://doi.org/10.1109/23.603705 |
Resumo: | In the present work we revisit the simplifying assumptions of an earlier theoretical treatment on the effects of grid misalignment on the performance of a planar gas proportional scintillation counter (GPSC). We present new experimental and computational results to establish the dependence of the effects of misalignment in terms of the reduced electric field in the scintillation region, the finite size of the electron cloud, and the solid angle subtended by the photosensor. It is shown that solid angle effects will offset to some degree the effects of grid misalignment in an optimized detector. For the reduced fields normally used in the scintillation region of an optimized GPSC (5 V cm -1 torr-1), misalignments as large as 3% have less than a 2% effect on pulse-amplitude variations. This effect is less than the statistical fluctuations in the number of primary electrons nominally produced in the absorption of X-rays in the 1- to 6-keV energy region. For reduced fields closer to the scintillation threshold (1 Vcm -1 torr-1), 15% variations in pulse amplitudes are possible, although it is unlikely that a GPSC would be operated under such unfavorable conditions |
id |
RCAP_179f8661b9c7d83f31e0d257ff4a1f46 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/12908 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
The effect of grid misalignment on the uniformity of response of gas proportional scintillation countersIn the present work we revisit the simplifying assumptions of an earlier theoretical treatment on the effects of grid misalignment on the performance of a planar gas proportional scintillation counter (GPSC). We present new experimental and computational results to establish the dependence of the effects of misalignment in terms of the reduced electric field in the scintillation region, the finite size of the electron cloud, and the solid angle subtended by the photosensor. It is shown that solid angle effects will offset to some degree the effects of grid misalignment in an optimized detector. For the reduced fields normally used in the scintillation region of an optimized GPSC (5 V cm -1 torr-1), misalignments as large as 3% have less than a 2% effect on pulse-amplitude variations. This effect is less than the statistical fluctuations in the number of primary electrons nominally produced in the absorption of X-rays in the 1- to 6-keV energy region. For reduced fields closer to the scintillation threshold (1 Vcm -1 torr-1), 15% variations in pulse amplitudes are possible, although it is unlikely that a GPSC would be operated under such unfavorable conditionsIEEE1997-06info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/12908http://hdl.handle.net/10316/12908https://doi.org/10.1109/23.603705engIEEE Transactions on Nuclear Science. 44:3 (1997) 527-5330018-9499Bento, A. C. S. S. M.Santos, J. M. F. dosMorgado, R. E.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2021-10-22T09:44:07Zoai:estudogeral.uc.pt:10316/12908Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:54.460654Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
The effect of grid misalignment on the uniformity of response of gas proportional scintillation counters |
title |
The effect of grid misalignment on the uniformity of response of gas proportional scintillation counters |
spellingShingle |
The effect of grid misalignment on the uniformity of response of gas proportional scintillation counters Bento, A. C. S. S. M. |
title_short |
The effect of grid misalignment on the uniformity of response of gas proportional scintillation counters |
title_full |
The effect of grid misalignment on the uniformity of response of gas proportional scintillation counters |
title_fullStr |
The effect of grid misalignment on the uniformity of response of gas proportional scintillation counters |
title_full_unstemmed |
The effect of grid misalignment on the uniformity of response of gas proportional scintillation counters |
title_sort |
The effect of grid misalignment on the uniformity of response of gas proportional scintillation counters |
author |
Bento, A. C. S. S. M. |
author_facet |
Bento, A. C. S. S. M. Santos, J. M. F. dos Morgado, R. E. |
author_role |
author |
author2 |
Santos, J. M. F. dos Morgado, R. E. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Bento, A. C. S. S. M. Santos, J. M. F. dos Morgado, R. E. |
description |
In the present work we revisit the simplifying assumptions of an earlier theoretical treatment on the effects of grid misalignment on the performance of a planar gas proportional scintillation counter (GPSC). We present new experimental and computational results to establish the dependence of the effects of misalignment in terms of the reduced electric field in the scintillation region, the finite size of the electron cloud, and the solid angle subtended by the photosensor. It is shown that solid angle effects will offset to some degree the effects of grid misalignment in an optimized detector. For the reduced fields normally used in the scintillation region of an optimized GPSC (5 V cm -1 torr-1), misalignments as large as 3% have less than a 2% effect on pulse-amplitude variations. This effect is less than the statistical fluctuations in the number of primary electrons nominally produced in the absorption of X-rays in the 1- to 6-keV energy region. For reduced fields closer to the scintillation threshold (1 Vcm -1 torr-1), 15% variations in pulse amplitudes are possible, although it is unlikely that a GPSC would be operated under such unfavorable conditions |
publishDate |
1997 |
dc.date.none.fl_str_mv |
1997-06 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/12908 http://hdl.handle.net/10316/12908 https://doi.org/10.1109/23.603705 |
url |
http://hdl.handle.net/10316/12908 https://doi.org/10.1109/23.603705 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
IEEE Transactions on Nuclear Science. 44:3 (1997) 527-533 0018-9499 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
IEEE |
publisher.none.fl_str_mv |
IEEE |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133889423212544 |