Allergic contact dermatitis from modified colophonium in wound dressings

Detalhes bibliográficos
Autor(a) principal: Pereira, TM
Data de Publicação: 2007
Outros Autores: Flour, M, Goossens, A
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.23/412
Resumo: This study concerns a 69-year-old female patient with a longstanding history of venous ulcerations on both lower legs and multiple sensitivities, who developed eczematous lesions with the hydrocolloid dressing Combiderm (Convatec Ltd., a Bristol-Myers Squibb division, Ickenham, Middlesex, UK). Epicutaneous tests were positive to this dressing and to a modified colophonium derivative, i.e. glyceryl rosinate, however not to the unmodified colophonium from the standard series. A review of the literature showed several case reports about sensitization to similar hydrocolloids being distributed under various brand names in different countries and which contain the pentaerythritol ester of the hydrogenated rosin as the tackifying agent. Some of the patients described did, while others did not, react to colophonium but only to a modified derivative. In our patient, the reaction to glyceryl rosinate most probably represent cross-sensitivity with the modified colophonium derivative used in Combiderm, the presence (but not the exact nature) of which was showed by the company. In patients where allergic contact dermatitis from hydrocolloid dressings is strongly suspected and colophonium tests negatively, patch testing to modified colophonium derivatives should therefore be performed. As the complete composition of wound dressings is most often unknown, we urgently advocate legal requirements for labelling of those and in fact all medically used devices.
id RCAP_1c2f9654f04202c32f98e9bf2d94dd73
oai_identifier_str oai:repositorio.hospitaldebraga.pt:10400.23/412
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Allergic contact dermatitis from modified colophonium in wound dressingsDermatitis Alérgica por ContactoÚlcera de PernaThis study concerns a 69-year-old female patient with a longstanding history of venous ulcerations on both lower legs and multiple sensitivities, who developed eczematous lesions with the hydrocolloid dressing Combiderm (Convatec Ltd., a Bristol-Myers Squibb division, Ickenham, Middlesex, UK). Epicutaneous tests were positive to this dressing and to a modified colophonium derivative, i.e. glyceryl rosinate, however not to the unmodified colophonium from the standard series. A review of the literature showed several case reports about sensitization to similar hydrocolloids being distributed under various brand names in different countries and which contain the pentaerythritol ester of the hydrogenated rosin as the tackifying agent. Some of the patients described did, while others did not, react to colophonium but only to a modified derivative. In our patient, the reaction to glyceryl rosinate most probably represent cross-sensitivity with the modified colophonium derivative used in Combiderm, the presence (but not the exact nature) of which was showed by the company. In patients where allergic contact dermatitis from hydrocolloid dressings is strongly suspected and colophonium tests negatively, patch testing to modified colophonium derivatives should therefore be performed. As the complete composition of wound dressings is most often unknown, we urgently advocate legal requirements for labelling of those and in fact all medically used devices.WileyRepositório Científico do Hospital de BragaPereira, TMFlour, MGoossens, A2013-03-14T16:05:03Z2007-01-01T00:00:00Z2007-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.23/412engContact Dermatitis. 2007;56(1):5-9.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-21T09:02:02Zoai:repositorio.hospitaldebraga.pt:10400.23/412Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:54:55.204580Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Allergic contact dermatitis from modified colophonium in wound dressings
title Allergic contact dermatitis from modified colophonium in wound dressings
spellingShingle Allergic contact dermatitis from modified colophonium in wound dressings
Pereira, TM
Dermatitis Alérgica por Contacto
Úlcera de Perna
title_short Allergic contact dermatitis from modified colophonium in wound dressings
title_full Allergic contact dermatitis from modified colophonium in wound dressings
title_fullStr Allergic contact dermatitis from modified colophonium in wound dressings
title_full_unstemmed Allergic contact dermatitis from modified colophonium in wound dressings
title_sort Allergic contact dermatitis from modified colophonium in wound dressings
author Pereira, TM
author_facet Pereira, TM
Flour, M
Goossens, A
author_role author
author2 Flour, M
Goossens, A
author2_role author
author
dc.contributor.none.fl_str_mv Repositório Científico do Hospital de Braga
dc.contributor.author.fl_str_mv Pereira, TM
Flour, M
Goossens, A
dc.subject.por.fl_str_mv Dermatitis Alérgica por Contacto
Úlcera de Perna
topic Dermatitis Alérgica por Contacto
Úlcera de Perna
description This study concerns a 69-year-old female patient with a longstanding history of venous ulcerations on both lower legs and multiple sensitivities, who developed eczematous lesions with the hydrocolloid dressing Combiderm (Convatec Ltd., a Bristol-Myers Squibb division, Ickenham, Middlesex, UK). Epicutaneous tests were positive to this dressing and to a modified colophonium derivative, i.e. glyceryl rosinate, however not to the unmodified colophonium from the standard series. A review of the literature showed several case reports about sensitization to similar hydrocolloids being distributed under various brand names in different countries and which contain the pentaerythritol ester of the hydrogenated rosin as the tackifying agent. Some of the patients described did, while others did not, react to colophonium but only to a modified derivative. In our patient, the reaction to glyceryl rosinate most probably represent cross-sensitivity with the modified colophonium derivative used in Combiderm, the presence (but not the exact nature) of which was showed by the company. In patients where allergic contact dermatitis from hydrocolloid dressings is strongly suspected and colophonium tests negatively, patch testing to modified colophonium derivatives should therefore be performed. As the complete composition of wound dressings is most often unknown, we urgently advocate legal requirements for labelling of those and in fact all medically used devices.
publishDate 2007
dc.date.none.fl_str_mv 2007-01-01T00:00:00Z
2007-01-01T00:00:00Z
2013-03-14T16:05:03Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.23/412
url http://hdl.handle.net/10400.23/412
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Contact Dermatitis. 2007;56(1):5-9.
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Wiley
publisher.none.fl_str_mv Wiley
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1817554006135799808