A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH)
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042022000500347 |
Resumo: | Abstract A membrane sensor using an ion association complex of hydroxyzine hydrochloride (HDH) with Orange II (ORG-II) dye, in a polyvinyl chloride (PVC) matrix, has been developed and used as a selective electrode for HDH quantification in pharmaceuticals. The sensor is suitable to determine 2.2 × 10-5 - 1.1 × 10-3 mol L-1 HDH, in the pH range from 2.5 to 5.21, with the Nernstian slope of 57.41±1.04 mV/decade, under optimum conditions. The regression coefficient (RC) value of 0.999 shows a good correlation between HDH concentration and the potential measured using the proposed sensor. The sensor limit of detection (LOD) was 4.5 × 10-6 M. A standard-addition procedure was followed to study the effect of various interferents. The results revealed no variations caused by foreign ions or species. The regression equation (RE) and relative standard deviation (RSD) values, from 1.67 to 5, and from 1.86 to 4.81%, respectively, indicated the HDH-ORG sensor acceptable accuracy and precision. The RSD values of ≤5.67 and <5% indicated the sensor acceptable robustness and ruggedness, respectively. It has been successfully used to determine HDH in tablets, and excellent results were obtained. |
id |
RCAP_2777af40f998969feaedc08f593d8574 |
---|---|
oai_identifier_str |
oai:scielo:S0872-19042022000500347 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH)HDHORG-IIion-associatePVCmembrane sensorAbstract A membrane sensor using an ion association complex of hydroxyzine hydrochloride (HDH) with Orange II (ORG-II) dye, in a polyvinyl chloride (PVC) matrix, has been developed and used as a selective electrode for HDH quantification in pharmaceuticals. The sensor is suitable to determine 2.2 × 10-5 - 1.1 × 10-3 mol L-1 HDH, in the pH range from 2.5 to 5.21, with the Nernstian slope of 57.41±1.04 mV/decade, under optimum conditions. The regression coefficient (RC) value of 0.999 shows a good correlation between HDH concentration and the potential measured using the proposed sensor. The sensor limit of detection (LOD) was 4.5 × 10-6 M. A standard-addition procedure was followed to study the effect of various interferents. The results revealed no variations caused by foreign ions or species. The regression equation (RE) and relative standard deviation (RSD) values, from 1.67 to 5, and from 1.86 to 4.81%, respectively, indicated the HDH-ORG sensor acceptable accuracy and precision. The RSD values of ≤5.67 and <5% indicated the sensor acceptable robustness and ruggedness, respectively. It has been successfully used to determine HDH in tablets, and excellent results were obtained.Sociedade Portuguesa de Electroquímica2022-10-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042022000500347Portugaliae Electrochimica Acta v.40 n.5 2022reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042022000500347Prasad,N. RajendraSiddaraju,C.info:eu-repo/semantics/openAccess2024-02-06T17:07:38Zoai:scielo:S0872-19042022000500347Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:20:29.548477Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH) |
title |
A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH) |
spellingShingle |
A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH) Prasad,N. Rajendra HDH ORG-II ion-associate PVC membrane sensor |
title_short |
A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH) |
title_full |
A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH) |
title_fullStr |
A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH) |
title_full_unstemmed |
A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH) |
title_sort |
A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH) |
author |
Prasad,N. Rajendra |
author_facet |
Prasad,N. Rajendra Siddaraju,C. |
author_role |
author |
author2 |
Siddaraju,C. |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Prasad,N. Rajendra Siddaraju,C. |
dc.subject.por.fl_str_mv |
HDH ORG-II ion-associate PVC membrane sensor |
topic |
HDH ORG-II ion-associate PVC membrane sensor |
description |
Abstract A membrane sensor using an ion association complex of hydroxyzine hydrochloride (HDH) with Orange II (ORG-II) dye, in a polyvinyl chloride (PVC) matrix, has been developed and used as a selective electrode for HDH quantification in pharmaceuticals. The sensor is suitable to determine 2.2 × 10-5 - 1.1 × 10-3 mol L-1 HDH, in the pH range from 2.5 to 5.21, with the Nernstian slope of 57.41±1.04 mV/decade, under optimum conditions. The regression coefficient (RC) value of 0.999 shows a good correlation between HDH concentration and the potential measured using the proposed sensor. The sensor limit of detection (LOD) was 4.5 × 10-6 M. A standard-addition procedure was followed to study the effect of various interferents. The results revealed no variations caused by foreign ions or species. The regression equation (RE) and relative standard deviation (RSD) values, from 1.67 to 5, and from 1.86 to 4.81%, respectively, indicated the HDH-ORG sensor acceptable accuracy and precision. The RSD values of ≤5.67 and <5% indicated the sensor acceptable robustness and ruggedness, respectively. It has been successfully used to determine HDH in tablets, and excellent results were obtained. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-10-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042022000500347 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042022000500347 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042022000500347 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
dc.source.none.fl_str_mv |
Portugaliae Electrochimica Acta v.40 n.5 2022 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137292488540160 |