Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimization

Detalhes bibliográficos
Autor(a) principal: Pinto Marques, Hugo
Data de Publicação: 2018
Outros Autores: de Araújo Gonçalves, Pedro, Ferreira, António Miguel, Cruz, Rita, Lopes, João, Santos, Rosana Dos, Radu, Lucian, Costa, Francisco, Mesquita, João, Carmo, Pedro, Cavaco, Diogo, Parreira, Leonor, Pisco, João, Goyri O'Neill, João, Adragão, Pedro
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10362/148208
Resumo: Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
id RCAP_2ee60e9cb524aa7162f890c4fc60d277
oai_identifier_str oai:run.unl.pt:10362/148208
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimizationAtrial fibrilationCardiac computed tomographyLeft atriumRadiation doseCopyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.BACKGROUND: Cardiac computed tomography (CT) can provide a precise tridimentional anatomic map and exclude intra-cardiac thrombus. We aimed to access the impact of CT protocol optimization and technological evolution on the contrast and radiation dose as well as on image quality previous to atrial fibrillation (AF) ablation. METHODS: From a prospective registry of consecutive patients who underwent cardiac CT in a single center, we selected 270 patients in whom the CT was done for evaluation prior to AF ablation and they were distributed in 3 groups: Group1: the first 150 patients included; Group2: the last 60 patients performed with the same CT scanner; Group3: the first 60 exams performed with the new CT scanner. Quality of the protocol was access based on radiation dose, contrast volume used, the use of a second (delayed) acquisition, and on quantitative image quality analisis (signal to noise and contrast to noise ratios; density homogeneity racio between LA and LAA). RESULTS: We found a significant radiation dose as well as contrast dose reduction between the first and last subgroups (G1: 5,6mSv and 100ml; G2: 1,3mSv and 90ml; G3: 0,6mSv and 65ml). Even though group 3 had less radiation and contrast used it still had better quantitative image quality (signal/noise of 13,5; contrast/noise 14,8; density homogeneity racio of 0,92). CONCLUSION: Protocol optimization and technology both contributed to significant lower radiation dose and contrast volume used on cardiac CTs prior to AF ablation, without compromising image quality.NOVA Medical School|Faculdade de Ciências Médicas (NMS|FCM)RUNPinto Marques, Hugode Araújo Gonçalves, PedroFerreira, António MiguelCruz, RitaLopes, JoãoSantos, Rosana DosRadu, LucianCosta, FranciscoMesquita, JoãoCarmo, PedroCavaco, DiogoParreira, LeonorPisco, JoãoGoyri O'Neill, JoãoAdragão, Pedro2023-01-26T22:10:26Z2018-112018-11-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article11application/pdfhttp://hdl.handle.net/10362/148208eng0870-2551PURE: 11114985https://doi.org/10.1016/j.repc.2018.03.011info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-10-21T01:36:32Zoai:run.unl.pt:10362/148208Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-10-21T01:36:32Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimization
title Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimization
spellingShingle Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimization
Pinto Marques, Hugo
Atrial fibrilation
Cardiac computed tomography
Left atrium
Radiation dose
title_short Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimization
title_full Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimization
title_fullStr Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimization
title_full_unstemmed Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimization
title_sort Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and protocol optimization
author Pinto Marques, Hugo
author_facet Pinto Marques, Hugo
de Araújo Gonçalves, Pedro
Ferreira, António Miguel
Cruz, Rita
Lopes, João
Santos, Rosana Dos
Radu, Lucian
Costa, Francisco
Mesquita, João
Carmo, Pedro
Cavaco, Diogo
Parreira, Leonor
Pisco, João
Goyri O'Neill, João
Adragão, Pedro
author_role author
author2 de Araújo Gonçalves, Pedro
Ferreira, António Miguel
Cruz, Rita
Lopes, João
Santos, Rosana Dos
Radu, Lucian
Costa, Francisco
Mesquita, João
Carmo, Pedro
Cavaco, Diogo
Parreira, Leonor
Pisco, João
Goyri O'Neill, João
Adragão, Pedro
author2_role author
author
author
author
author
author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv NOVA Medical School|Faculdade de Ciências Médicas (NMS|FCM)
RUN
dc.contributor.author.fl_str_mv Pinto Marques, Hugo
de Araújo Gonçalves, Pedro
Ferreira, António Miguel
Cruz, Rita
Lopes, João
Santos, Rosana Dos
Radu, Lucian
Costa, Francisco
Mesquita, João
Carmo, Pedro
Cavaco, Diogo
Parreira, Leonor
Pisco, João
Goyri O'Neill, João
Adragão, Pedro
dc.subject.por.fl_str_mv Atrial fibrilation
Cardiac computed tomography
Left atrium
Radiation dose
topic Atrial fibrilation
Cardiac computed tomography
Left atrium
Radiation dose
description Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
publishDate 2018
dc.date.none.fl_str_mv 2018-11
2018-11-01T00:00:00Z
2023-01-26T22:10:26Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10362/148208
url http://hdl.handle.net/10362/148208
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0870-2551
PURE: 11114985
https://doi.org/10.1016/j.repc.2018.03.011
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 11
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv mluisa.alvim@gmail.com
_version_ 1817545912329699328