Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/3869 |
Resumo: | The corrosion behavior of four different preparations of plasma-sprayed hydroxyapatite (HA) coatings on Ti6Al4V substrates in static Hank's balanced salt solution was investigated using dc potentiodynamic and ac impedance techniques. Two different nominal thicknesses, 50 m and 200 m, and two different spraying conditions, were considered. The electrochemical impedance experiments proved this technique to be very suitable for the investigation of the electrochemical behavior of surgical implant alloys when they are coated with HA, which is characterized by the dissolution and passivation characteristics of the underlying metal substrate. Because the coatings are porous, ionic paths between the electrolytic medium and the base material can eventually be produced, resulting in the corrosion of the coated metal. Differences in the corrosion resistance of the coated materials were detected, and a relevant model for the description of the coating degradation in the biosimulating solution was proposed. The model consisted of the description of the coated system in terms of a two-layer model of the surface film. Significant differences in electrochemical behavior for similar nominal thicknesses of HA coatings obtained under different spraying conditions were found |
id |
RCAP_3390fef476bbbb5cb2abba00e92b449b |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/3869 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrateBiomaterialsHydroxyapatiteTi6Al4VPlasma-sprayed coatingsCorrosion resistanceTi6A14VScience & TechnologyThe corrosion behavior of four different preparations of plasma-sprayed hydroxyapatite (HA) coatings on Ti6Al4V substrates in static Hank's balanced salt solution was investigated using dc potentiodynamic and ac impedance techniques. Two different nominal thicknesses, 50 m and 200 m, and two different spraying conditions, were considered. The electrochemical impedance experiments proved this technique to be very suitable for the investigation of the electrochemical behavior of surgical implant alloys when they are coated with HA, which is characterized by the dissolution and passivation characteristics of the underlying metal substrate. Because the coatings are porous, ionic paths between the electrolytic medium and the base material can eventually be produced, resulting in the corrosion of the coated metal. Differences in the corrosion resistance of the coated materials were detected, and a relevant model for the description of the coating degradation in the biosimulating solution was proposed. The model consisted of the description of the coated system in terms of a two-layer model of the surface film. Significant differences in electrochemical behavior for similar nominal thicknesses of HA coatings obtained under different spraying conditions were foundMinisterio de Ciencia y Tecnología (Madrid, Spain) contract grant number: BQU2000-0864.WileyUniversidade do MinhoSouto, R. M.Lemus, M. M.Reis, R. L.20042004-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/3869eng"Journal of Biomedical Materials Research : Part A". ISSN 1097-4636. 70 A:1 (July 2004) 59-65.1097-463610.1002/jbm.a.3006115174109info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T11:58:29Zoai:repositorium.sdum.uminho.pt:1822/3869Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:48:13.718354Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate |
title |
Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate |
spellingShingle |
Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate Souto, R. M. Biomaterials Hydroxyapatite Ti6Al4V Plasma-sprayed coatings Corrosion resistance Ti6A14V Science & Technology |
title_short |
Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate |
title_full |
Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate |
title_fullStr |
Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate |
title_full_unstemmed |
Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate |
title_sort |
Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate |
author |
Souto, R. M. |
author_facet |
Souto, R. M. Lemus, M. M. Reis, R. L. |
author_role |
author |
author2 |
Lemus, M. M. Reis, R. L. |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Souto, R. M. Lemus, M. M. Reis, R. L. |
dc.subject.por.fl_str_mv |
Biomaterials Hydroxyapatite Ti6Al4V Plasma-sprayed coatings Corrosion resistance Ti6A14V Science & Technology |
topic |
Biomaterials Hydroxyapatite Ti6Al4V Plasma-sprayed coatings Corrosion resistance Ti6A14V Science & Technology |
description |
The corrosion behavior of four different preparations of plasma-sprayed hydroxyapatite (HA) coatings on Ti6Al4V substrates in static Hank's balanced salt solution was investigated using dc potentiodynamic and ac impedance techniques. Two different nominal thicknesses, 50 m and 200 m, and two different spraying conditions, were considered. The electrochemical impedance experiments proved this technique to be very suitable for the investigation of the electrochemical behavior of surgical implant alloys when they are coated with HA, which is characterized by the dissolution and passivation characteristics of the underlying metal substrate. Because the coatings are porous, ionic paths between the electrolytic medium and the base material can eventually be produced, resulting in the corrosion of the coated metal. Differences in the corrosion resistance of the coated materials were detected, and a relevant model for the description of the coating degradation in the biosimulating solution was proposed. The model consisted of the description of the coated system in terms of a two-layer model of the surface film. Significant differences in electrochemical behavior for similar nominal thicknesses of HA coatings obtained under different spraying conditions were found |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004 2004-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/3869 |
url |
http://hdl.handle.net/1822/3869 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
"Journal of Biomedical Materials Research : Part A". ISSN 1097-4636. 70 A:1 (July 2004) 59-65. 1097-4636 10.1002/jbm.a.30061 15174109 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Wiley |
publisher.none.fl_str_mv |
Wiley |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132242992168960 |