Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate

Detalhes bibliográficos
Autor(a) principal: Souto, R. M.
Data de Publicação: 2004
Outros Autores: Lemus, M. M., Reis, R. L.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/3869
Resumo: The corrosion behavior of four different preparations of plasma-sprayed hydroxyapatite (HA) coatings on Ti6Al4V substrates in static Hank's balanced salt solution was investigated using dc potentiodynamic and ac impedance techniques. Two different nominal thicknesses, 50 m and 200 m, and two different spraying conditions, were considered. The electrochemical impedance experiments proved this technique to be very suitable for the investigation of the electrochemical behavior of surgical implant alloys when they are coated with HA, which is characterized by the dissolution and passivation characteristics of the underlying metal substrate. Because the coatings are porous, ionic paths between the electrolytic medium and the base material can eventually be produced, resulting in the corrosion of the coated metal. Differences in the corrosion resistance of the coated materials were detected, and a relevant model for the description of the coating degradation in the biosimulating solution was proposed. The model consisted of the description of the coated system in terms of a two-layer model of the surface film. Significant differences in electrochemical behavior for similar nominal thicknesses of HA coatings obtained under different spraying conditions were found
id RCAP_3390fef476bbbb5cb2abba00e92b449b
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/3869
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrateBiomaterialsHydroxyapatiteTi6Al4VPlasma-sprayed coatingsCorrosion resistanceTi6A14VScience & TechnologyThe corrosion behavior of four different preparations of plasma-sprayed hydroxyapatite (HA) coatings on Ti6Al4V substrates in static Hank's balanced salt solution was investigated using dc potentiodynamic and ac impedance techniques. Two different nominal thicknesses, 50 m and 200 m, and two different spraying conditions, were considered. The electrochemical impedance experiments proved this technique to be very suitable for the investigation of the electrochemical behavior of surgical implant alloys when they are coated with HA, which is characterized by the dissolution and passivation characteristics of the underlying metal substrate. Because the coatings are porous, ionic paths between the electrolytic medium and the base material can eventually be produced, resulting in the corrosion of the coated metal. Differences in the corrosion resistance of the coated materials were detected, and a relevant model for the description of the coating degradation in the biosimulating solution was proposed. The model consisted of the description of the coated system in terms of a two-layer model of the surface film. Significant differences in electrochemical behavior for similar nominal thicknesses of HA coatings obtained under different spraying conditions were foundMinisterio de Ciencia y Tecnología (Madrid, Spain) contract grant number: BQU2000-0864.WileyUniversidade do MinhoSouto, R. M.Lemus, M. M.Reis, R. L.20042004-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/3869eng"Journal of Biomedical Materials Research : Part A". ISSN 1097-4636. 70 A:1 (July 2004) 59-65.1097-463610.1002/jbm.a.3006115174109info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T11:58:29Zoai:repositorium.sdum.uminho.pt:1822/3869Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:48:13.718354Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate
title Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate
spellingShingle Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate
Souto, R. M.
Biomaterials
Hydroxyapatite
Ti6Al4V
Plasma-sprayed coatings
Corrosion resistance
Ti6A14V
Science & Technology
title_short Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate
title_full Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate
title_fullStr Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate
title_full_unstemmed Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate
title_sort Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6A14V substrate
author Souto, R. M.
author_facet Souto, R. M.
Lemus, M. M.
Reis, R. L.
author_role author
author2 Lemus, M. M.
Reis, R. L.
author2_role author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Souto, R. M.
Lemus, M. M.
Reis, R. L.
dc.subject.por.fl_str_mv Biomaterials
Hydroxyapatite
Ti6Al4V
Plasma-sprayed coatings
Corrosion resistance
Ti6A14V
Science & Technology
topic Biomaterials
Hydroxyapatite
Ti6Al4V
Plasma-sprayed coatings
Corrosion resistance
Ti6A14V
Science & Technology
description The corrosion behavior of four different preparations of plasma-sprayed hydroxyapatite (HA) coatings on Ti6Al4V substrates in static Hank's balanced salt solution was investigated using dc potentiodynamic and ac impedance techniques. Two different nominal thicknesses, 50 m and 200 m, and two different spraying conditions, were considered. The electrochemical impedance experiments proved this technique to be very suitable for the investigation of the electrochemical behavior of surgical implant alloys when they are coated with HA, which is characterized by the dissolution and passivation characteristics of the underlying metal substrate. Because the coatings are porous, ionic paths between the electrolytic medium and the base material can eventually be produced, resulting in the corrosion of the coated metal. Differences in the corrosion resistance of the coated materials were detected, and a relevant model for the description of the coating degradation in the biosimulating solution was proposed. The model consisted of the description of the coated system in terms of a two-layer model of the surface film. Significant differences in electrochemical behavior for similar nominal thicknesses of HA coatings obtained under different spraying conditions were found
publishDate 2004
dc.date.none.fl_str_mv 2004
2004-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/3869
url http://hdl.handle.net/1822/3869
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv "Journal of Biomedical Materials Research : Part A". ISSN 1097-4636. 70 A:1 (July 2004) 59-65.
1097-4636
10.1002/jbm.a.30061
15174109
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Wiley
publisher.none.fl_str_mv Wiley
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132242992168960