A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica aguda

Detalhes bibliográficos
Autor(a) principal: Pimenta, Tiago Marques
Data de Publicação: 2014
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/28597
Resumo: Trabalho final de mestrado integrado em Medicina (Imagiologia Médica), apresentada á Faculdade de Medicina da Universidade de Coimbra
id RCAP_34f4ec4b830594bb5df0fed77204aa85
oai_identifier_str oai:estudogeral.uc.pt:10316/28597
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica agudaTomografia por emissão computorizadaMarcadores biológicosAortaTrabalho final de mestrado integrado em Medicina (Imagiologia Médica), apresentada á Faculdade de Medicina da Universidade de CoimbraA Síndrome Aórtica Aguda (SAA) é incomum, grave e requer um diagnóstico e tratamento precoces em virtude de se associar a elevadas taxas de mortalidade. No seu algoritmo diagnóstico estão habitualmente incluídos uma avaliação laboratorial sumária e exames imagiológicos, sendo o método de imagem mais comumente utilizado na sua abordagem inicial a tomografia computorizada (TC), a qual permitirá excluir o diagnóstico em muitos dos casos em que é colocada essa suspeita. Por outro lado, são também usados biomarcadores como os D-dímeros, leucócitos, proteína C reactiva (PCR), creatina cinase (CK) e troponina I como indicadores de probabilidade no diagnóstico. Neste trabalho seleccionou-se uma amostra de doentes submetidos a angiografia torácica e/ou abdominal por TC multidetectores com suspeita de SAA ou com esse diagnóstico confirmado, num período de três anos (2010-2012), com posterior recolha dos dados relativos ao doseamento sérico dos biomarcadores referidos acima. Realizou-se uma avaliação demográfica e da prevalência da SAA, verificou-se a relação entre a suspeita e a confirmação do diagnóstico através da TC e compararam-se os doseamentos séricos médios entre os doentes com e sem SAA. Verificou-se uma baixa prevalência da SAA no conjunto de TC realizadas (aproximadamente 1,09%), num total de 33 casos; o diagnóstico foi confirmado apenas em cerca de um quarto dos casos em que existia uma suspeita inicial. O doseamento dos biomarcadores PCR, CK e troponina I não mostrou propriedades diagnósticas favoráveis. Quanto aos leucócitos, apesar de terem sido encontradas médias com diferença significativa entre grupos, não parecem ter utilidade como ferramenta diagnóstica na SAA. Os D-dímeros apresentaram um valor preditivo negativo de 92% para o valor de corte de 1,57 µg/mL, mostrando assim ser o biomarcador com maior utilidade na SAA, pois a sua exclusão será muito provável para valores inferiores aos referidos. Para este valor de corte, a acuidade diagnóstica foi de 88%, embora a utilidade como ferramenta de exclusão se considere superior à sua utilidade como forma de confirmar o diagnóstico. Concluiu-se com este trabalho que a TC é um método imagiológico útil no esclarecimento da suspeita de SAA, permitindo excluir esse diagnóstico na sua maioria. Consideramos que o doseamento sérico dos D-dímeros deverá fazer parte de uma abordagem diagnóstica integrada com a realização de exame imagiológico, pois poderá contribuir para excluir ou elevar a suspeita de SAA, seleccionando de uma forma mais eficiente os doentes que devem ser melhor estudados por TC.Acute Aortic Syndrome (AAS) is uncommon, serious and requires early diagnosis and treatment due to its high mortality rates. Its diagnostic algorithm typically includes a basic laboratory evaluation and imaging modalities. The most commonly used imaging modality in the initial management of this syndrome is the computed tomography (CT), which will exclude the diagnosis in many suspected cases. On the other hand, biomarkers as D-dimers, leukocytes, C-reactive protein (CRP), creatine kinase (CK) and troponin I are also used as indicators of diagnostic probability. In our study, we selected a sample of patients undergoing thoracic and/or abdominal multidetector CT angiography with suspected AAS or with this diagnosis confirmed, during a three-year period (2010-2012), with subsequent collection of data on the serum assay for the referred biomarkers. We conducted a brief demographic evaluation and studied the prevalence of AAS, verified the relationship between suspicion and confirmation of diagnosis by CT and compared the values of serum assays between patients with and without AAS in our sample. There was a low prevalence of AAS diagnosed by CT (approximately 1,09%); there were 33 cases of AAS and the diagnosis was confirmed in only about a quarter of the suspected cases. PCR, CK and troponin I didn't show satisfactory diagnostic properties. As for leukocytes, although significant mean difference between groups was found, they don’t seem to have utility as a diagnostic tool for AAS. D-dimers showed a negative predictive value of 92% at a cutoff of 1,57 µg/mL, thus proving to be the most useful biomarker in AAS, once its exclusion is very likely below those values. At this cutoff, the diagnostic accuracy was 88%, although its usefulness for exclusion of AAS is considered to exceed its usefulness as a way to confirm the diagnosis. We concluded that CT is a useful imaging method in clarifying the suspicion of AAS, allowing its exclusion in the majority of cases. We consider that determination of serum D-dimers should be part of an integrated diagnostic approach with the imaging examination, once it may help exclude or raise the suspicion of AAS, selecting in a more efficient manner those who should be better studied by CT.2014info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/28597http://hdl.handle.net/10316/28597TID:201627493porPimenta, Tiago Marquesinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-01-20T17:48:47Zoai:estudogeral.uc.pt:10316/28597Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:44:54.338746Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica aguda
title A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica aguda
spellingShingle A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica aguda
Pimenta, Tiago Marques
Tomografia por emissão computorizada
Marcadores biológicos
Aorta
title_short A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica aguda
title_full A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica aguda
title_fullStr A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica aguda
title_full_unstemmed A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica aguda
title_sort A tomografia computorizada e os marcadores biológicos na avaliação da síndrome aórtica aguda
author Pimenta, Tiago Marques
author_facet Pimenta, Tiago Marques
author_role author
dc.contributor.author.fl_str_mv Pimenta, Tiago Marques
dc.subject.por.fl_str_mv Tomografia por emissão computorizada
Marcadores biológicos
Aorta
topic Tomografia por emissão computorizada
Marcadores biológicos
Aorta
description Trabalho final de mestrado integrado em Medicina (Imagiologia Médica), apresentada á Faculdade de Medicina da Universidade de Coimbra
publishDate 2014
dc.date.none.fl_str_mv 2014
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/28597
http://hdl.handle.net/10316/28597
TID:201627493
url http://hdl.handle.net/10316/28597
identifier_str_mv TID:201627493
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133723209236480