CFD parametric studies for global performance improvement of open refrigerated display cabinets
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.6/7267 |
Resumo: | A detailed CFD modelling of an open refrigerated display cabinet has been formulated in a previous study. Some modifications are introduced in order to perform parametric studies dealing with low-cost geometrical and functional characteristics for improvement of the global performance and energy efficiency. The parametric studies are devoted to the analysis of the thermal response and behaviour inside the food conservation space influenced by (1) air flow rate through the evaporator heat exchanger; (2) air curtain behaviour; (3) hole dimensions and distribution of the back panel; (4) discharge and return grilles angles; and (5) flow deflectors inside the internal duct. The analysis of the numerical predictions from the parametric studies allows the development of an optimized model for the conception of an open refrigerated display cabinet with a more adequate configuration. The numerical predictions of the optimized model show lower product temperature and reduced electrical energy consumption, allowing the improvement of the food safety and the energy rationalization of the refrigeration equipment. |
id |
RCAP_35dbeca8cd56eebf41b50bca2532be96 |
---|---|
oai_identifier_str |
oai:ubibliorum.ubi.pt:10400.6/7267 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
CFD parametric studies for global performance improvement of open refrigerated display cabinetsComputational fluid dynamicsA detailed CFD modelling of an open refrigerated display cabinet has been formulated in a previous study. Some modifications are introduced in order to perform parametric studies dealing with low-cost geometrical and functional characteristics for improvement of the global performance and energy efficiency. The parametric studies are devoted to the analysis of the thermal response and behaviour inside the food conservation space influenced by (1) air flow rate through the evaporator heat exchanger; (2) air curtain behaviour; (3) hole dimensions and distribution of the back panel; (4) discharge and return grilles angles; and (5) flow deflectors inside the internal duct. The analysis of the numerical predictions from the parametric studies allows the development of an optimized model for the conception of an open refrigerated display cabinet with a more adequate configuration. The numerical predictions of the optimized model show lower product temperature and reduced electrical energy consumption, allowing the improvement of the food safety and the energy rationalization of the refrigeration equipment.Hindawi Publishing CorporationuBibliorumGaspar, Pedro DinisGonçalves, Luís Carlos CarrilhoPitarma, R. A.2019-10-17T15:32:26Z20122012-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.6/7267eng1687-559110.1155/2012/867820info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-15T09:46:30Zoai:ubibliorum.ubi.pt:10400.6/7267Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:47:49.366519Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
CFD parametric studies for global performance improvement of open refrigerated display cabinets |
title |
CFD parametric studies for global performance improvement of open refrigerated display cabinets |
spellingShingle |
CFD parametric studies for global performance improvement of open refrigerated display cabinets Gaspar, Pedro Dinis Computational fluid dynamics |
title_short |
CFD parametric studies for global performance improvement of open refrigerated display cabinets |
title_full |
CFD parametric studies for global performance improvement of open refrigerated display cabinets |
title_fullStr |
CFD parametric studies for global performance improvement of open refrigerated display cabinets |
title_full_unstemmed |
CFD parametric studies for global performance improvement of open refrigerated display cabinets |
title_sort |
CFD parametric studies for global performance improvement of open refrigerated display cabinets |
author |
Gaspar, Pedro Dinis |
author_facet |
Gaspar, Pedro Dinis Gonçalves, Luís Carlos Carrilho Pitarma, R. A. |
author_role |
author |
author2 |
Gonçalves, Luís Carlos Carrilho Pitarma, R. A. |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
uBibliorum |
dc.contributor.author.fl_str_mv |
Gaspar, Pedro Dinis Gonçalves, Luís Carlos Carrilho Pitarma, R. A. |
dc.subject.por.fl_str_mv |
Computational fluid dynamics |
topic |
Computational fluid dynamics |
description |
A detailed CFD modelling of an open refrigerated display cabinet has been formulated in a previous study. Some modifications are introduced in order to perform parametric studies dealing with low-cost geometrical and functional characteristics for improvement of the global performance and energy efficiency. The parametric studies are devoted to the analysis of the thermal response and behaviour inside the food conservation space influenced by (1) air flow rate through the evaporator heat exchanger; (2) air curtain behaviour; (3) hole dimensions and distribution of the back panel; (4) discharge and return grilles angles; and (5) flow deflectors inside the internal duct. The analysis of the numerical predictions from the parametric studies allows the development of an optimized model for the conception of an open refrigerated display cabinet with a more adequate configuration. The numerical predictions of the optimized model show lower product temperature and reduced electrical energy consumption, allowing the improvement of the food safety and the energy rationalization of the refrigeration equipment. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012 2012-01-01T00:00:00Z 2019-10-17T15:32:26Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.6/7267 |
url |
http://hdl.handle.net/10400.6/7267 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1687-5591 10.1155/2012/867820 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Hindawi Publishing Corporation |
publisher.none.fl_str_mv |
Hindawi Publishing Corporation |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799136373399093248 |