Measurements in first-trimester abortion products a pathologic study

Detalhes bibliográficos
Autor(a) principal: Cardoso, Rosete Maria Amorim Novais Nogueira
Data de Publicação: 2020
Outros Autores: Sousa, Sara, Braga, A. C., Azevedo, Ana, Pereira, Nuno, Carmo, Olímpia, Tavares, Maria Purificação, Correia-Pinto, Jorge
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/70514
Resumo: Context.-Related to the advances in prenatal diagnosis and the emergence of medically challenging situations, there has been an increased interest in conducting a pathologic study of first-trimester abortion products. Objective.-To evaluate measurements across a large group of first-trimester spontaneous abortion specimens. Potential goals include a validation of prenatal embryo and gestational-sac measurements as a function of gestational age (GA). Design.-A retrospective case study of first-trimester spontaneous abortions between June 2015 and April 2017 in Centro de Genética Clínica Embryo-Fetal Pathology Laboratory, Porto, Portugal. Considering the inclusion criteria, 585 complete gestational sacs, 182 embryos, and 116 umbilical cords were selected. We recorded the weight of the gestational sacs and embryos and measurements of gestational sacs, umbilical cords, and embryo crown-rump length. Models were computed using regression techniques. Results.-Gestational-sac diameter percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval the diameter increased an average of 3 mm. Umbilical cord length percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval, the length increased an average of 1.35 mm. Embryo crown-rump length estimated mean 6 SD values were GA 6 weeks, 5.3 6 2.3 mm; GA 7 weeks, 9.4 6 4.8 mm; GA 8 weeks, 13.7 6 8.2 mm; GA 9 weeks, 20.8 6 9.1 mm; GA 10 weeks, 22.6 6 13.4 mm; GA 11 weeks, 29.4 6 12.9 mm; and GA 12 weeks, 52 mm. Conclusions.-Pathologic measurements obtained should be compared to expected measurements and correlated with ultrasound findings, clinical information, and microscopic findings. Deviations from expected values could lead to an understanding of early pregnancy loss.
id RCAP_396014b322c96ecb7bbd53c199cc3496
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/70514
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Measurements in first-trimester abortion products a pathologic studyScience & TechnologyContext.-Related to the advances in prenatal diagnosis and the emergence of medically challenging situations, there has been an increased interest in conducting a pathologic study of first-trimester abortion products. Objective.-To evaluate measurements across a large group of first-trimester spontaneous abortion specimens. Potential goals include a validation of prenatal embryo and gestational-sac measurements as a function of gestational age (GA). Design.-A retrospective case study of first-trimester spontaneous abortions between June 2015 and April 2017 in Centro de Genética Clínica Embryo-Fetal Pathology Laboratory, Porto, Portugal. Considering the inclusion criteria, 585 complete gestational sacs, 182 embryos, and 116 umbilical cords were selected. We recorded the weight of the gestational sacs and embryos and measurements of gestational sacs, umbilical cords, and embryo crown-rump length. Models were computed using regression techniques. Results.-Gestational-sac diameter percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval the diameter increased an average of 3 mm. Umbilical cord length percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval, the length increased an average of 1.35 mm. Embryo crown-rump length estimated mean 6 SD values were GA 6 weeks, 5.3 6 2.3 mm; GA 7 weeks, 9.4 6 4.8 mm; GA 8 weeks, 13.7 6 8.2 mm; GA 9 weeks, 20.8 6 9.1 mm; GA 10 weeks, 22.6 6 13.4 mm; GA 11 weeks, 29.4 6 12.9 mm; and GA 12 weeks, 52 mm. Conclusions.-Pathologic measurements obtained should be compared to expected measurements and correlated with ultrasound findings, clinical information, and microscopic findings. Deviations from expected values could lead to an understanding of early pregnancy loss.This work was developed under the scope of the project NORTE-01-0145-FEDER-000013, NORTE-01-0145-FEDER-000023, supported by the Northern Portugal Regional Operational Programme (NORTE 2020) under the Portugal Partnership Agreement, through the European Regional Development Fund (FEDER), and through the Competitiveness Factors Operational Programme (COMPETE) and by national funds, through the Foundation for Science and Technology (FCT), under the scope of the project POCI-01-0145-FEDER-007038 Centro de Genética Clínica, CGC Genetics, Porto Portugal. The authors have no relevant financial interest in the products or companies described in this article.College of American PathologistsUniversidade do MinhoCardoso, Rosete Maria Amorim Novais NogueiraSousa, SaraBraga, A. C.Azevedo, AnaPereira, NunoCarmo, OlímpiaTavares, Maria PurificaçãoCorreia-Pinto, Jorge20202020-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/70514engRosete Nogueira, Sara Sousa, Ana Cristina Braga, Ana Azevedo, Nuno Pereira, Olímpia Carmo, Maria Purificação Tavares, Jorge Correia Pinto; Measurements in First-Trimester Abortion Products: A Pathologic Study. Arch Pathol Lab Med 1 February 2020; 144 (2): 207–214. doi: https://doi.org/10.5858/arpa.2018-0181-OA0003-998510.5858/arpa.2018-0181-OA31173530https://meridian.allenpress.com/aplm/article/144/2/207/433650/Measurements-in-First-Trimester-Abortion-Productsinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:33:24Zoai:repositorium.sdum.uminho.pt:1822/70514Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:28:55.501499Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Measurements in first-trimester abortion products a pathologic study
title Measurements in first-trimester abortion products a pathologic study
spellingShingle Measurements in first-trimester abortion products a pathologic study
Cardoso, Rosete Maria Amorim Novais Nogueira
Science & Technology
title_short Measurements in first-trimester abortion products a pathologic study
title_full Measurements in first-trimester abortion products a pathologic study
title_fullStr Measurements in first-trimester abortion products a pathologic study
title_full_unstemmed Measurements in first-trimester abortion products a pathologic study
title_sort Measurements in first-trimester abortion products a pathologic study
author Cardoso, Rosete Maria Amorim Novais Nogueira
author_facet Cardoso, Rosete Maria Amorim Novais Nogueira
Sousa, Sara
Braga, A. C.
Azevedo, Ana
Pereira, Nuno
Carmo, Olímpia
Tavares, Maria Purificação
Correia-Pinto, Jorge
author_role author
author2 Sousa, Sara
Braga, A. C.
Azevedo, Ana
Pereira, Nuno
Carmo, Olímpia
Tavares, Maria Purificação
Correia-Pinto, Jorge
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Cardoso, Rosete Maria Amorim Novais Nogueira
Sousa, Sara
Braga, A. C.
Azevedo, Ana
Pereira, Nuno
Carmo, Olímpia
Tavares, Maria Purificação
Correia-Pinto, Jorge
dc.subject.por.fl_str_mv Science & Technology
topic Science & Technology
description Context.-Related to the advances in prenatal diagnosis and the emergence of medically challenging situations, there has been an increased interest in conducting a pathologic study of first-trimester abortion products. Objective.-To evaluate measurements across a large group of first-trimester spontaneous abortion specimens. Potential goals include a validation of prenatal embryo and gestational-sac measurements as a function of gestational age (GA). Design.-A retrospective case study of first-trimester spontaneous abortions between June 2015 and April 2017 in Centro de Genética Clínica Embryo-Fetal Pathology Laboratory, Porto, Portugal. Considering the inclusion criteria, 585 complete gestational sacs, 182 embryos, and 116 umbilical cords were selected. We recorded the weight of the gestational sacs and embryos and measurements of gestational sacs, umbilical cords, and embryo crown-rump length. Models were computed using regression techniques. Results.-Gestational-sac diameter percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval the diameter increased an average of 3 mm. Umbilical cord length percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval, the length increased an average of 1.35 mm. Embryo crown-rump length estimated mean 6 SD values were GA 6 weeks, 5.3 6 2.3 mm; GA 7 weeks, 9.4 6 4.8 mm; GA 8 weeks, 13.7 6 8.2 mm; GA 9 weeks, 20.8 6 9.1 mm; GA 10 weeks, 22.6 6 13.4 mm; GA 11 weeks, 29.4 6 12.9 mm; and GA 12 weeks, 52 mm. Conclusions.-Pathologic measurements obtained should be compared to expected measurements and correlated with ultrasound findings, clinical information, and microscopic findings. Deviations from expected values could lead to an understanding of early pregnancy loss.
publishDate 2020
dc.date.none.fl_str_mv 2020
2020-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/70514
url http://hdl.handle.net/1822/70514
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Rosete Nogueira, Sara Sousa, Ana Cristina Braga, Ana Azevedo, Nuno Pereira, Olímpia Carmo, Maria Purificação Tavares, Jorge Correia Pinto; Measurements in First-Trimester Abortion Products: A Pathologic Study. Arch Pathol Lab Med 1 February 2020; 144 (2): 207–214. doi: https://doi.org/10.5858/arpa.2018-0181-OA
0003-9985
10.5858/arpa.2018-0181-OA
31173530
https://meridian.allenpress.com/aplm/article/144/2/207/433650/Measurements-in-First-Trimester-Abortion-Products
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv College of American Pathologists
publisher.none.fl_str_mv College of American Pathologists
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132787026952192