Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Tipo de documento: | Dissertação |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.21/7190 |
Resumo: | Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Imagem Funcional e Multimodal |
id |
RCAP_3b751dc423cc97c1d68b2b800562d147 |
---|---|
oai_identifier_str |
oai:repositorio.ipl.pt:10400.21/7190 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scannersMedicina nuclearPET/CTTOFTempo de aquisiçãoQualidade de imagemNuclear medicineTime-of-flightAcquisition timeImage quality88GaMestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Imagem Funcional e MultimodalNa Tomografia por Emissão de Positrões (PET) têm sido feitas melhorias significativas para superar a qualidade de imagem, nomeadamente a incorporação do tempo de voo (TOF) nos tomógrafos. Esta técnica é útil para localizar o ponto de emissão do radiofármaco emissor de positrões dentro do organismo, medindo a diferença dos tempos de deteção dos fotões em coincidência. Os equipamentos PET com tecnologia TOF proporcionam uma melhoria na razão sinal-ruído (SNR) e uma diminuição das coincidências aleatórias, permitindo, assim, melhor contraste das lesões, sobretudo em pacientes obesos, e maior detalhe das estruturas, possibilitando ainda menores tempos de aquisição de imagens ou menores atividades administradas. Os objetivos principais deste estudo consistem em investigar o menor tempo de aquisição, sem comprometer a qualidade de imagem num fantoma de corpo NEMA e determinar como é que isso pode ser traduzido num melhor desempenho nas imagens dos pacientes.ABSTRACT - Significant improvements have been made in Positron Emission Tomography (PET) to enhance the image quality, namely, the development of time-of-flight (TOF) technology. This technique is useful to localize the emission point of the beta plus-emiter radiopharmaceutical inside the body, by measuring the difference in coincident photon detection times. TOF PET scanners enable an improvement signal-to-noise ratio (SNR) and decrease of random coincidences, allowing better lesion contrast, especially for large patients, improving structural details and leading to a short scan time or injected dose. The main goals of this study are to investigate the shortest acquisition time without compromising the image quality in a NEMA body phantom and to determine how it translates into improved performance for patient imaging.Instituto Politécnico de Lisboa, Escola Superior de Tecnologia da Saúde de LisboaBranco, SusanaParafita, RuiRCIPLOliveira, Joana da Fonseca e2017-06-21T10:05:06Z2016-07-182016-07-18T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10400.21/7190TID:201355132engOliveira JF. Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners [Dissertation]. Lisbon: Escola Superior de Tecnologia da Saúde de Lisboa/Instituto Politécnico de Lisboa; 2016.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T09:52:56Zoai:repositorio.ipl.pt:10400.21/7190Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:16:11.500408Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners |
title |
Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners |
spellingShingle |
Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners Oliveira, Joana da Fonseca e Medicina nuclear PET/CT TOF Tempo de aquisição Qualidade de imagem Nuclear medicine Time-of-flight Acquisition time Image quality 88Ga |
title_short |
Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners |
title_full |
Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners |
title_fullStr |
Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners |
title_full_unstemmed |
Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners |
title_sort |
Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners |
author |
Oliveira, Joana da Fonseca e |
author_facet |
Oliveira, Joana da Fonseca e |
author_role |
author |
dc.contributor.none.fl_str_mv |
Branco, Susana Parafita, Rui RCIPL |
dc.contributor.author.fl_str_mv |
Oliveira, Joana da Fonseca e |
dc.subject.por.fl_str_mv |
Medicina nuclear PET/CT TOF Tempo de aquisição Qualidade de imagem Nuclear medicine Time-of-flight Acquisition time Image quality 88Ga |
topic |
Medicina nuclear PET/CT TOF Tempo de aquisição Qualidade de imagem Nuclear medicine Time-of-flight Acquisition time Image quality 88Ga |
description |
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Imagem Funcional e Multimodal |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-07-18 2016-07-18T00:00:00Z 2017-06-21T10:05:06Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.21/7190 TID:201355132 |
url |
http://hdl.handle.net/10400.21/7190 |
identifier_str_mv |
TID:201355132 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Oliveira JF. Influence of the time-of-flight and the acquisition time on image quality in positron emission tomography/computed tomography scanners [Dissertation]. Lisbon: Escola Superior de Tecnologia da Saúde de Lisboa/Instituto Politécnico de Lisboa; 2016. |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Instituto Politécnico de Lisboa, Escola Superior de Tecnologia da Saúde de Lisboa |
publisher.none.fl_str_mv |
Instituto Politécnico de Lisboa, Escola Superior de Tecnologia da Saúde de Lisboa |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133421869465600 |