Estudo da Qualidade do Ar Interior num edifício departamental da UC

Detalhes bibliográficos
Autor(a) principal: Costa, Cristina Maria Ponte
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/20148
Resumo: Dissertação de Mestrado em Engenharia do Ambiente apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.
id RCAP_3e27e582ae808c3403831f011e69f8dd
oai_identifier_str oai:estudogeral.uc.pt:10316/20148
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Estudo da Qualidade do Ar Interior num edifício departamental da UCQualidade do Ar interiorDissertação de Mestrado em Engenharia do Ambiente apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.Nas últimas décadas, a qualidade do ar interior (QAI) tem sido considerada como uma das principais causas para o desconforto, degradação da saúde e baixo desempenho dos ocupantes de estabelecimentos de ensino. Num local como o Departamento de Engenharia Mecânica da Faculdade de Ciências e Tecnologia da Universidade de Coimbra (DEM-FCTUC), onde estudantes, docentes e funcionários passam grande parte do seu dia, urge a avaliação da QAI. Um dos objectivos do presente trabalho foi auditar a QAI do DEM-FCTUC, para a emissão do seu certificado energético e de QAI. Outros objectivos foram i) a análise da percepção individual das condições de conforto interior associado à QAI e ii) a avaliação dos sintomas derivados à baixa QAI na saúde dos ocupantes. A QAI foi avaliada em 50 espaços de 23 zonas do DEM, através da verificação da higiene e manutenção dos sistemas AVAC e da medição dos parâmetros impostos pela legislação nacional: Partículas suspensas no ar (PM10), Dióxido de Carbono (CO2), Monóxido de Carbono (CO), Ozono (O3), Formaldeído (HCHO), Compostos Orgânicos Voláteis Totais (COVT), Bactérias, Fungos, Temperatura e Humidade Relativa. A percepção individual e os sintomas foram analisados através da distribuição de questionários juntos dos alunos em quatro salas de aula. As medições estenderam-se em duas campanhas. Os resultados mostram que a concentração de PM10 excedeu o limite legal em 4 espaços. Por outro lado a concentração de CO2 foi ultrapassada em 46% dos espaços segundo o 1º critério de conformidade do RSECE e em 2 espaços apenas considerando o 2º critério, indicando aí uma ventilação inadequada. As concentrações de CO, O3, e COVT não revelaram problemas nos espaços. O formaldeído atingiu um valor superior ao regulamentar em apenas um espaço que foi avaliado com detalhe. As bactérias mais comuns foram os cocus Gram (+) e os fungos foram os Cladosporium sp e Penicillium sp. As condições de conforto térmico (Temperatura e Humidade Relativa) não se revelaram preocupantes. Foram feitas recomendações ao proprietário com vista a uma melhoria das condições mais críticas e a obtenção do certificado energético e de QAI. Da análise dos questionários, constatou-se que os alunos têm uma maior percepção da situação térmica do espaço do que do nível de humidade ou da falta de QAI. Os sintomas mais sentidos foram a garganta seca ou rouca e a tosse. Futuros estudos deverão ser propostos para descobrir uma adequada estratégia de ventilação, essencial para melhorar a QAI nesteedifício.Abstract In the last few decades, the indoor air quality (IAQ) has been considered as a principal cause of discomfort, health problems and low performance of the scholar buildings occupants. The building of the DEM-FCTUC is occupied by students, teachers and staff, thus it is very important to evaluate the IAQ. The main goal of this study was to analyze its IAQ and to prepare it to get the energy and IAQ certificate according to the national certification system. Other objectives were (i) the assessment of the individual perception to indoor environmental conditions related to IAQ problems and (ii) the study of the relationship between health symptoms and poor IAQ. The IAQwas assessed by checking the hygiene and maintenance of Heating, Ventilation and Air Conditioning (HVAC) systems and by measuring in 50 spaces distributed by 23 sampling zones the following parameters, as determined by the national law: Airborne Particle Matter (PM10), Carbon Dioxide (CO2), Carbon Monoxide (CO), Ozone (O3), Formaldehyde (HCHO), Total Volatile Organic Compounds (VOCT), Bacteria, Fungi, Temperature and Relative Humidity. The individual perception and the symptoms were analyzed through surveys to students in four classrooms. The measurements were carried out in two campaigns. The results showed excessive values of the PM10 concentration in four spaces. On the other hand, the CO2 concentration limit was exceeded in 46% of the spaces according to the first criteria of compliance with RSECE and in two spaces the second compliance criteria was not fulfilled, concluding that these spaces have inadequate ventilation. The concentrations of CO, O3 and VOCT revealed no significant problem. The formaldehyde concentration rose to an amount higher than the threshold proposed by the law in one space, which was better evaluated in order to find its source. The most common bacteria found were cocus Gram (+), while the most common Fungi were the Cladosporium sp and Penicillium sp. The Temperature and the Relative Humidity proved to be not worrying. Some recommendations were made to the manager of the building with the purpose of achieving the certificate and to improve the critical conditions that were found. After analyzing the surveys, it was concluded that the students can better perceive the thermal situation of the space instead of the humidity levels or the lack of IAQ. The symptoms often felt by the students were dry throat or hoarse and cough. Future works should be done in this building to find adequate ventilation as an essential way to improve its IAQ.2011-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/20148http://hdl.handle.net/10316/20148porCOSTA, Cristina Maria Ponte Costa. Estudo da Qualidade do Ar Interior num edifício departamental da UC. Coimbra: [s.n.],2011. Dissertação de MestradoCosta, Cristina Maria Ponteinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-01-20T17:49:04Zoai:estudogeral.uc.pt:10316/20148Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:58:48.219752Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Estudo da Qualidade do Ar Interior num edifício departamental da UC
title Estudo da Qualidade do Ar Interior num edifício departamental da UC
spellingShingle Estudo da Qualidade do Ar Interior num edifício departamental da UC
Costa, Cristina Maria Ponte
Qualidade do Ar interior
title_short Estudo da Qualidade do Ar Interior num edifício departamental da UC
title_full Estudo da Qualidade do Ar Interior num edifício departamental da UC
title_fullStr Estudo da Qualidade do Ar Interior num edifício departamental da UC
title_full_unstemmed Estudo da Qualidade do Ar Interior num edifício departamental da UC
title_sort Estudo da Qualidade do Ar Interior num edifício departamental da UC
author Costa, Cristina Maria Ponte
author_facet Costa, Cristina Maria Ponte
author_role author
dc.contributor.author.fl_str_mv Costa, Cristina Maria Ponte
dc.subject.por.fl_str_mv Qualidade do Ar interior
topic Qualidade do Ar interior
description Dissertação de Mestrado em Engenharia do Ambiente apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.
publishDate 2011
dc.date.none.fl_str_mv 2011-09
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/20148
http://hdl.handle.net/10316/20148
url http://hdl.handle.net/10316/20148
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv COSTA, Cristina Maria Ponte Costa. Estudo da Qualidade do Ar Interior num edifício departamental da UC. Coimbra: [s.n.],2011. Dissertação de Mestrado
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133880180015104