The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting

Detalhes bibliográficos
Autor(a) principal: Marques, Alda
Data de Publicação: 2009
Outros Autores: Bruton, Anne, Barney, Anna
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10773/22423
Resumo: Lung sounds provide useful information for assessing and monitoring respiratory patients, but standard auscultation is subjective. Computer aided lung sound analysis (CALSA) enables the quantification and characterisation of added lung sounds (e.g. crackles). At present, little is known about the reliability of these sound characteristics. Therefore, the aim of this study was to explore the reliability of crackle initial deflection width (IDW) and two-cycle deflection (2CD) in a clinical population. Fifty-four subjects (37 bronchiectasis, 17 cystic fibrosis) were recruited from out-patient clinics. Three repeated lung sound recordings were taken at seven anatomical sites with a digital stethoscope connected to a laptop computer. The intra-subject reliability of crackle IDW and 2CD was found to be 'good' to 'excellent', estimated by the analysis of variance, intraclass correlation coefficient (IDW 0.76;0.85, 2CD 0.83;0.94), Bland and Altman 95% limits of agreement (IDW −0.50;0.47 ms, 2CD −2.12;1.87 ms) and smallest real difference (IDW 0.30;0.66 ms, 2CD 1.57;2.42 ms). Crackle 2CD was found to be more reliable than IDW. It is concluded that crackle IDW and 2CD characterized by CALSA have good test–retest reliability. This technique requires further evaluation since CALSA has potential to diagnose or monitor respiratory conditions, and provide an objective physiological measure for respiratory interventions.
id RCAP_3f74535ee85978c5f4284780b3a85ed6
oai_identifier_str oai:ria.ua.pt:10773/22423
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical settingCracklesLung soundsReliabilityLung sounds provide useful information for assessing and monitoring respiratory patients, but standard auscultation is subjective. Computer aided lung sound analysis (CALSA) enables the quantification and characterisation of added lung sounds (e.g. crackles). At present, little is known about the reliability of these sound characteristics. Therefore, the aim of this study was to explore the reliability of crackle initial deflection width (IDW) and two-cycle deflection (2CD) in a clinical population. Fifty-four subjects (37 bronchiectasis, 17 cystic fibrosis) were recruited from out-patient clinics. Three repeated lung sound recordings were taken at seven anatomical sites with a digital stethoscope connected to a laptop computer. The intra-subject reliability of crackle IDW and 2CD was found to be 'good' to 'excellent', estimated by the analysis of variance, intraclass correlation coefficient (IDW 0.76;0.85, 2CD 0.83;0.94), Bland and Altman 95% limits of agreement (IDW −0.50;0.47 ms, 2CD −2.12;1.87 ms) and smallest real difference (IDW 0.30;0.66 ms, 2CD 1.57;2.42 ms). Crackle 2CD was found to be more reliable than IDW. It is concluded that crackle IDW and 2CD characterized by CALSA have good test–retest reliability. This technique requires further evaluation since CALSA has potential to diagnose or monitor respiratory conditions, and provide an objective physiological measure for respiratory interventions.IOP Publishing2018-02-28T14:59:52Z2009-07-30T00:00:00Z2009-07-30info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10773/22423eng0967-333410.1088/0967-3334/30/9/003Marques, AldaBruton, AnneBarney, Annainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-02-22T11:43:51Zoai:ria.ua.pt:10773/22423Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:56:31.793709Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting
title The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting
spellingShingle The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting
Marques, Alda
Crackles
Lung sounds
Reliability
title_short The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting
title_full The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting
title_fullStr The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting
title_full_unstemmed The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting
title_sort The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting
author Marques, Alda
author_facet Marques, Alda
Bruton, Anne
Barney, Anna
author_role author
author2 Bruton, Anne
Barney, Anna
author2_role author
author
dc.contributor.author.fl_str_mv Marques, Alda
Bruton, Anne
Barney, Anna
dc.subject.por.fl_str_mv Crackles
Lung sounds
Reliability
topic Crackles
Lung sounds
Reliability
description Lung sounds provide useful information for assessing and monitoring respiratory patients, but standard auscultation is subjective. Computer aided lung sound analysis (CALSA) enables the quantification and characterisation of added lung sounds (e.g. crackles). At present, little is known about the reliability of these sound characteristics. Therefore, the aim of this study was to explore the reliability of crackle initial deflection width (IDW) and two-cycle deflection (2CD) in a clinical population. Fifty-four subjects (37 bronchiectasis, 17 cystic fibrosis) were recruited from out-patient clinics. Three repeated lung sound recordings were taken at seven anatomical sites with a digital stethoscope connected to a laptop computer. The intra-subject reliability of crackle IDW and 2CD was found to be 'good' to 'excellent', estimated by the analysis of variance, intraclass correlation coefficient (IDW 0.76;0.85, 2CD 0.83;0.94), Bland and Altman 95% limits of agreement (IDW −0.50;0.47 ms, 2CD −2.12;1.87 ms) and smallest real difference (IDW 0.30;0.66 ms, 2CD 1.57;2.42 ms). Crackle 2CD was found to be more reliable than IDW. It is concluded that crackle IDW and 2CD characterized by CALSA have good test–retest reliability. This technique requires further evaluation since CALSA has potential to diagnose or monitor respiratory conditions, and provide an objective physiological measure for respiratory interventions.
publishDate 2009
dc.date.none.fl_str_mv 2009-07-30T00:00:00Z
2009-07-30
2018-02-28T14:59:52Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10773/22423
url http://hdl.handle.net/10773/22423
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0967-3334
10.1088/0967-3334/30/9/003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv IOP Publishing
publisher.none.fl_str_mv IOP Publishing
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137619241598976