Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.22/14914 |
Resumo: | Tranexamic acid (TXA) is an antifibrinolytic drug, with the ability to inhibit lysine binding at plasminogen receptors, used in adult trauma patients with on-going or at risk of significant haemorrhage. To understand the pharmacokinetics and pharmacodynamics of this drug in variable age groups undergoing surgeries with high blood loss, effective methods for determination of TXA in biological samples at sub-μg mL−1 are still required. We describe herein the development and validation of a method based on ultra-high performance liquid chromatography coupled to triple quadrupole-tandem mass spectrometry to quantify TXA in human plasma. An inexpensive, simple and efficient sample clean-up was implemented, not requiring matrix-matching calibration. Sample preparation consisted in protein precipitation using acetonitrile containing 0.5% (v/v) formic acid, followed by hydrophilic interaction based chromatographic separation, with elution in isocratic mode using a combination of acetonitrile and water (75:25, v/v), with quantification of TXA based on selected reaction monitoring. Good linearity was achieved (r2 > 0.997) for TXA concentrations ranging from 30 to 600 ng mL−1, with LOD of 18 ng mL−1 in plasma. The developed method proved to be selective, sensitive, accurate (96.4–105.7% of nominal values) and precise (RSD ≤ 4.5%). TXA was found to be stable in plasma extracts standing 24 h at room temperature (20 °C) or in the autosampler, and after three freeze-thawing cycles. Mean recovery values of TXA spiked plasma samples were ≥91.9%. No significant matrix effects were observed. The proposed methodology was successfully applied to the clinical study of plasma samples recovered during scoliosis surgery of pediatric patients pretreatment with TXA. |
id |
RCAP_45f7bf69a7c5f3edb07e95b90294d059 |
---|---|
oai_identifier_str |
oai:recipp.ipp.pt:10400.22/14914 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levelsAntifibrinolyticPharmacokineticsDrug monitoringMass spectrometryPlasmaTranexamic acid (TXA) is an antifibrinolytic drug, with the ability to inhibit lysine binding at plasminogen receptors, used in adult trauma patients with on-going or at risk of significant haemorrhage. To understand the pharmacokinetics and pharmacodynamics of this drug in variable age groups undergoing surgeries with high blood loss, effective methods for determination of TXA in biological samples at sub-μg mL−1 are still required. We describe herein the development and validation of a method based on ultra-high performance liquid chromatography coupled to triple quadrupole-tandem mass spectrometry to quantify TXA in human plasma. An inexpensive, simple and efficient sample clean-up was implemented, not requiring matrix-matching calibration. Sample preparation consisted in protein precipitation using acetonitrile containing 0.5% (v/v) formic acid, followed by hydrophilic interaction based chromatographic separation, with elution in isocratic mode using a combination of acetonitrile and water (75:25, v/v), with quantification of TXA based on selected reaction monitoring. Good linearity was achieved (r2 > 0.997) for TXA concentrations ranging from 30 to 600 ng mL−1, with LOD of 18 ng mL−1 in plasma. The developed method proved to be selective, sensitive, accurate (96.4–105.7% of nominal values) and precise (RSD ≤ 4.5%). TXA was found to be stable in plasma extracts standing 24 h at room temperature (20 °C) or in the autosampler, and after three freeze-thawing cycles. Mean recovery values of TXA spiked plasma samples were ≥91.9%. No significant matrix effects were observed. The proposed methodology was successfully applied to the clinical study of plasma samples recovered during scoliosis surgery of pediatric patients pretreatment with TXA.ElsevierRepositório Científico do Instituto Politécnico do PortoBarreiros, LuisaAmoreira, Júlia L.Machado, SandiaFernandes, Sara R.Silva, Eduarda M.P.Sá, PaulaKietaibl, SibylleSegundo, Marcela A.2021-03-03T01:30:35Z20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/14914eng10.1016/j.microc.2018.08.061info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:58:33Zoai:recipp.ipp.pt:10400.22/14914Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:34:43.148159Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels |
title |
Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels |
spellingShingle |
Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels Barreiros, Luisa Antifibrinolytic Pharmacokinetics Drug monitoring Mass spectrometry Plasma |
title_short |
Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels |
title_full |
Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels |
title_fullStr |
Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels |
title_full_unstemmed |
Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels |
title_sort |
Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels |
author |
Barreiros, Luisa |
author_facet |
Barreiros, Luisa Amoreira, Júlia L. Machado, Sandia Fernandes, Sara R. Silva, Eduarda M.P. Sá, Paula Kietaibl, Sibylle Segundo, Marcela A. |
author_role |
author |
author2 |
Amoreira, Júlia L. Machado, Sandia Fernandes, Sara R. Silva, Eduarda M.P. Sá, Paula Kietaibl, Sibylle Segundo, Marcela A. |
author2_role |
author author author author author author author |
dc.contributor.none.fl_str_mv |
Repositório Científico do Instituto Politécnico do Porto |
dc.contributor.author.fl_str_mv |
Barreiros, Luisa Amoreira, Júlia L. Machado, Sandia Fernandes, Sara R. Silva, Eduarda M.P. Sá, Paula Kietaibl, Sibylle Segundo, Marcela A. |
dc.subject.por.fl_str_mv |
Antifibrinolytic Pharmacokinetics Drug monitoring Mass spectrometry Plasma |
topic |
Antifibrinolytic Pharmacokinetics Drug monitoring Mass spectrometry Plasma |
description |
Tranexamic acid (TXA) is an antifibrinolytic drug, with the ability to inhibit lysine binding at plasminogen receptors, used in adult trauma patients with on-going or at risk of significant haemorrhage. To understand the pharmacokinetics and pharmacodynamics of this drug in variable age groups undergoing surgeries with high blood loss, effective methods for determination of TXA in biological samples at sub-μg mL−1 are still required. We describe herein the development and validation of a method based on ultra-high performance liquid chromatography coupled to triple quadrupole-tandem mass spectrometry to quantify TXA in human plasma. An inexpensive, simple and efficient sample clean-up was implemented, not requiring matrix-matching calibration. Sample preparation consisted in protein precipitation using acetonitrile containing 0.5% (v/v) formic acid, followed by hydrophilic interaction based chromatographic separation, with elution in isocratic mode using a combination of acetonitrile and water (75:25, v/v), with quantification of TXA based on selected reaction monitoring. Good linearity was achieved (r2 > 0.997) for TXA concentrations ranging from 30 to 600 ng mL−1, with LOD of 18 ng mL−1 in plasma. The developed method proved to be selective, sensitive, accurate (96.4–105.7% of nominal values) and precise (RSD ≤ 4.5%). TXA was found to be stable in plasma extracts standing 24 h at room temperature (20 °C) or in the autosampler, and after three freeze-thawing cycles. Mean recovery values of TXA spiked plasma samples were ≥91.9%. No significant matrix effects were observed. The proposed methodology was successfully applied to the clinical study of plasma samples recovered during scoliosis surgery of pediatric patients pretreatment with TXA. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 2019-01-01T00:00:00Z 2021-03-03T01:30:35Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.22/14914 |
url |
http://hdl.handle.net/10400.22/14914 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.microc.2018.08.061 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799131438853914624 |