An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serum
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042020000100003 |
Resumo: | A sensitive, accurate electrochemical sensor based on reduced graphene oxide modified carbon paste electrode (RGO/CPE) was developed to measure curcumin levels in human blood serum. The as-prepared electrode (RGO/CPE) was verified to outperform bare carbon paste electrode (CPE), with increased oxidation and reduction peaks at +0.505 V and +0.408 V, respectively. Curcumin measurement was performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. RGO/CPE showed a desirable linear response towards curcumin, within the concentration range of 10-6000 µM; the detection limit (S/N = 3) was 3.183 µM. Moreover, electrochemical impedance spectroscopy (EIS) and field emission scanning electron microscope (FESEM) were applied to gain further insight into the electrochemical behavior of the proposed electrode. The results revealed that the usage of RGO caused increased sensitivity of the sensor response to curcumin; therefore, RGO/CPE can be considered a promising electrochemical sensor for curcumin determination in human blood serum. |
id |
RCAP_4834fb9f8ecf4d0c2aa687fc3406a194 |
---|---|
oai_identifier_str |
oai:scielo:S0872-19042020000100003 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serumcurcuminreduced graphene oxidecarbon paste electrodeelectrochemical sensordifferential pulse voltammetryA sensitive, accurate electrochemical sensor based on reduced graphene oxide modified carbon paste electrode (RGO/CPE) was developed to measure curcumin levels in human blood serum. The as-prepared electrode (RGO/CPE) was verified to outperform bare carbon paste electrode (CPE), with increased oxidation and reduction peaks at +0.505 V and +0.408 V, respectively. Curcumin measurement was performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. RGO/CPE showed a desirable linear response towards curcumin, within the concentration range of 10-6000 µM; the detection limit (S/N = 3) was 3.183 µM. Moreover, electrochemical impedance spectroscopy (EIS) and field emission scanning electron microscope (FESEM) were applied to gain further insight into the electrochemical behavior of the proposed electrode. The results revealed that the usage of RGO caused increased sensitivity of the sensor response to curcumin; therefore, RGO/CPE can be considered a promising electrochemical sensor for curcumin determination in human blood serum.Sociedade Portuguesa de Electroquímica2020-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042020000100003Portugaliae Electrochimica Acta v.38 n.1 2020reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042020000100003Rahimnejad,MostafaZokhtareh,RosanMoghadamnia,Ali AkbarAsghary,Maryaminfo:eu-repo/semantics/openAccess2024-02-06T17:07:31Zoai:scielo:S0872-19042020000100003Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:20:25.499395Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serum |
title |
An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serum |
spellingShingle |
An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serum Rahimnejad,Mostafa curcumin reduced graphene oxide carbon paste electrode electrochemical sensor differential pulse voltammetry |
title_short |
An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serum |
title_full |
An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serum |
title_fullStr |
An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serum |
title_full_unstemmed |
An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serum |
title_sort |
An Electrochemical Sensor Based on Reduced Graphene Oxide Modified Carbon Paste Electrode for Curcumin Determination in Human Blood Serum |
author |
Rahimnejad,Mostafa |
author_facet |
Rahimnejad,Mostafa Zokhtareh,Rosan Moghadamnia,Ali Akbar Asghary,Maryam |
author_role |
author |
author2 |
Zokhtareh,Rosan Moghadamnia,Ali Akbar Asghary,Maryam |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Rahimnejad,Mostafa Zokhtareh,Rosan Moghadamnia,Ali Akbar Asghary,Maryam |
dc.subject.por.fl_str_mv |
curcumin reduced graphene oxide carbon paste electrode electrochemical sensor differential pulse voltammetry |
topic |
curcumin reduced graphene oxide carbon paste electrode electrochemical sensor differential pulse voltammetry |
description |
A sensitive, accurate electrochemical sensor based on reduced graphene oxide modified carbon paste electrode (RGO/CPE) was developed to measure curcumin levels in human blood serum. The as-prepared electrode (RGO/CPE) was verified to outperform bare carbon paste electrode (CPE), with increased oxidation and reduction peaks at +0.505 V and +0.408 V, respectively. Curcumin measurement was performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. RGO/CPE showed a desirable linear response towards curcumin, within the concentration range of 10-6000 µM; the detection limit (S/N = 3) was 3.183 µM. Moreover, electrochemical impedance spectroscopy (EIS) and field emission scanning electron microscope (FESEM) were applied to gain further insight into the electrochemical behavior of the proposed electrode. The results revealed that the usage of RGO caused increased sensitivity of the sensor response to curcumin; therefore, RGO/CPE can be considered a promising electrochemical sensor for curcumin determination in human blood serum. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042020000100003 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042020000100003 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042020000100003 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
dc.source.none.fl_str_mv |
Portugaliae Electrochimica Acta v.38 n.1 2020 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137291957960704 |