Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts

Detalhes bibliográficos
Autor(a) principal: Amaral, Joana S.
Data de Publicação: 2005
Outros Autores: Casal, Susana, Seabra, Rosa M., Oliveira, Beatriz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10198/632
Resumo: A high performance liquid chromatographic (HPLC) method for the determination of tocopherols and tocotrienols in walnut samples is described. The compounds were extracted with n-hexane, using a simple solid-liquid extraction procedure. Tocol was used as internal standard and BHT as anti-oxidant. The ehromatographic separation was achieved using an Inertsil 5 SI normal phase column operating with isocratic elution of n-hexane/1,4-dioxane (96.5:3.5, v/v), at a flow rate of 0.7 mL/min. The effluent was monitored by a series arrangement of a diodearray detector followed by a fluorescence detector. The detection limits were low, between 0.037 and 0.266 (jig/mL. The method was precise (% CV less than2.8%), accurate (% CV less than 5.6%), and, as a general rule, the recovery values were high (mean values ranging from 93.4% to 104%).
id RCAP_4e7a55f4d3a77b45836bf99b3f35cc30
oai_identifier_str oai:bibliotecadigital.ipb.pt:10198/632
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnutsTocopherolTocotrienolNormal phase liquid chromatographyWalnutsA high performance liquid chromatographic (HPLC) method for the determination of tocopherols and tocotrienols in walnut samples is described. The compounds were extracted with n-hexane, using a simple solid-liquid extraction procedure. Tocol was used as internal standard and BHT as anti-oxidant. The ehromatographic separation was achieved using an Inertsil 5 SI normal phase column operating with isocratic elution of n-hexane/1,4-dioxane (96.5:3.5, v/v), at a flow rate of 0.7 mL/min. The effluent was monitored by a series arrangement of a diodearray detector followed by a fluorescence detector. The detection limits were low, between 0.037 and 0.266 (jig/mL. The method was precise (% CV less than2.8%), accurate (% CV less than 5.6%), and, as a general rule, the recovery values were high (mean values ranging from 93.4% to 104%).Taylor & FrancisBiblioteca Digital do IPBAmaral, Joana S.Casal, SusanaSeabra, Rosa M.Oliveira, Beatriz2008-05-28T10:35:48Z20052005-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10198/632engengAmaral, J.S.; Casal, S.; Seabra, R. M.; Oliveira, M.B.P.P. (2005). Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts. Journal of Liquid Chromatography and Related Technologies. ISSN 1082-6076. 28:5, p.785-7951082-6076Journal of Liquid Chromatography and Related Technologies10.1081/JLC-200048920info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-21T10:03:40Zoai:bibliotecadigital.ipb.pt:10198/632Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T22:54:22.095686Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts
title Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts
spellingShingle Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts
Amaral, Joana S.
Tocopherol
Tocotrienol
Normal phase liquid chromatography
Walnuts
title_short Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts
title_full Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts
title_fullStr Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts
title_full_unstemmed Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts
title_sort Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts
author Amaral, Joana S.
author_facet Amaral, Joana S.
Casal, Susana
Seabra, Rosa M.
Oliveira, Beatriz
author_role author
author2 Casal, Susana
Seabra, Rosa M.
Oliveira, Beatriz
author2_role author
author
author
dc.contributor.none.fl_str_mv Biblioteca Digital do IPB
dc.contributor.author.fl_str_mv Amaral, Joana S.
Casal, Susana
Seabra, Rosa M.
Oliveira, Beatriz
dc.subject.por.fl_str_mv Tocopherol
Tocotrienol
Normal phase liquid chromatography
Walnuts
topic Tocopherol
Tocotrienol
Normal phase liquid chromatography
Walnuts
description A high performance liquid chromatographic (HPLC) method for the determination of tocopherols and tocotrienols in walnut samples is described. The compounds were extracted with n-hexane, using a simple solid-liquid extraction procedure. Tocol was used as internal standard and BHT as anti-oxidant. The ehromatographic separation was achieved using an Inertsil 5 SI normal phase column operating with isocratic elution of n-hexane/1,4-dioxane (96.5:3.5, v/v), at a flow rate of 0.7 mL/min. The effluent was monitored by a series arrangement of a diodearray detector followed by a fluorescence detector. The detection limits were low, between 0.037 and 0.266 (jig/mL. The method was precise (% CV less than2.8%), accurate (% CV less than 5.6%), and, as a general rule, the recovery values were high (mean values ranging from 93.4% to 104%).
publishDate 2005
dc.date.none.fl_str_mv 2005
2005-01-01T00:00:00Z
2008-05-28T10:35:48Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10198/632
url http://hdl.handle.net/10198/632
dc.language.iso.fl_str_mv eng
eng
language eng
dc.relation.none.fl_str_mv Amaral, J.S.; Casal, S.; Seabra, R. M.; Oliveira, M.B.P.P. (2005). Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts. Journal of Liquid Chromatography and Related Technologies. ISSN 1082-6076. 28:5, p.785-795
1082-6076
Journal of Liquid Chromatography and Related Technologies
10.1081/JLC-200048920
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Taylor & Francis
publisher.none.fl_str_mv Taylor & Francis
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799135142569050112