Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10198/632 |
Resumo: | A high performance liquid chromatographic (HPLC) method for the determination of tocopherols and tocotrienols in walnut samples is described. The compounds were extracted with n-hexane, using a simple solid-liquid extraction procedure. Tocol was used as internal standard and BHT as anti-oxidant. The ehromatographic separation was achieved using an Inertsil 5 SI normal phase column operating with isocratic elution of n-hexane/1,4-dioxane (96.5:3.5, v/v), at a flow rate of 0.7 mL/min. The effluent was monitored by a series arrangement of a diodearray detector followed by a fluorescence detector. The detection limits were low, between 0.037 and 0.266 (jig/mL. The method was precise (% CV less than2.8%), accurate (% CV less than 5.6%), and, as a general rule, the recovery values were high (mean values ranging from 93.4% to 104%). |
id |
RCAP_4e7a55f4d3a77b45836bf99b3f35cc30 |
---|---|
oai_identifier_str |
oai:bibliotecadigital.ipb.pt:10198/632 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnutsTocopherolTocotrienolNormal phase liquid chromatographyWalnutsA high performance liquid chromatographic (HPLC) method for the determination of tocopherols and tocotrienols in walnut samples is described. The compounds were extracted with n-hexane, using a simple solid-liquid extraction procedure. Tocol was used as internal standard and BHT as anti-oxidant. The ehromatographic separation was achieved using an Inertsil 5 SI normal phase column operating with isocratic elution of n-hexane/1,4-dioxane (96.5:3.5, v/v), at a flow rate of 0.7 mL/min. The effluent was monitored by a series arrangement of a diodearray detector followed by a fluorescence detector. The detection limits were low, between 0.037 and 0.266 (jig/mL. The method was precise (% CV less than2.8%), accurate (% CV less than 5.6%), and, as a general rule, the recovery values were high (mean values ranging from 93.4% to 104%).Taylor & FrancisBiblioteca Digital do IPBAmaral, Joana S.Casal, SusanaSeabra, Rosa M.Oliveira, Beatriz2008-05-28T10:35:48Z20052005-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10198/632engengAmaral, J.S.; Casal, S.; Seabra, R. M.; Oliveira, M.B.P.P. (2005). Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts. Journal of Liquid Chromatography and Related Technologies. ISSN 1082-6076. 28:5, p.785-7951082-6076Journal of Liquid Chromatography and Related Technologies10.1081/JLC-200048920info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-21T10:03:40Zoai:bibliotecadigital.ipb.pt:10198/632Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T22:54:22.095686Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts |
title |
Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts |
spellingShingle |
Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts Amaral, Joana S. Tocopherol Tocotrienol Normal phase liquid chromatography Walnuts |
title_short |
Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts |
title_full |
Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts |
title_fullStr |
Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts |
title_full_unstemmed |
Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts |
title_sort |
Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts |
author |
Amaral, Joana S. |
author_facet |
Amaral, Joana S. Casal, Susana Seabra, Rosa M. Oliveira, Beatriz |
author_role |
author |
author2 |
Casal, Susana Seabra, Rosa M. Oliveira, Beatriz |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Biblioteca Digital do IPB |
dc.contributor.author.fl_str_mv |
Amaral, Joana S. Casal, Susana Seabra, Rosa M. Oliveira, Beatriz |
dc.subject.por.fl_str_mv |
Tocopherol Tocotrienol Normal phase liquid chromatography Walnuts |
topic |
Tocopherol Tocotrienol Normal phase liquid chromatography Walnuts |
description |
A high performance liquid chromatographic (HPLC) method for the determination of tocopherols and tocotrienols in walnut samples is described. The compounds were extracted with n-hexane, using a simple solid-liquid extraction procedure. Tocol was used as internal standard and BHT as anti-oxidant. The ehromatographic separation was achieved using an Inertsil 5 SI normal phase column operating with isocratic elution of n-hexane/1,4-dioxane (96.5:3.5, v/v), at a flow rate of 0.7 mL/min. The effluent was monitored by a series arrangement of a diodearray detector followed by a fluorescence detector. The detection limits were low, between 0.037 and 0.266 (jig/mL. The method was precise (% CV less than2.8%), accurate (% CV less than 5.6%), and, as a general rule, the recovery values were high (mean values ranging from 93.4% to 104%). |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005 2005-01-01T00:00:00Z 2008-05-28T10:35:48Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10198/632 |
url |
http://hdl.handle.net/10198/632 |
dc.language.iso.fl_str_mv |
eng eng |
language |
eng |
dc.relation.none.fl_str_mv |
Amaral, J.S.; Casal, S.; Seabra, R. M.; Oliveira, M.B.P.P. (2005). Development and evaluation of a normal phase liquid chromatographic method for the determination of tocopherols and tocotrienols in walnuts. Journal of Liquid Chromatography and Related Technologies. ISSN 1082-6076. 28:5, p.785-795 1082-6076 Journal of Liquid Chromatography and Related Technologies 10.1081/JLC-200048920 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Taylor & Francis |
publisher.none.fl_str_mv |
Taylor & Francis |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799135142569050112 |