Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic Retinopathy
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10362/159338 |
Resumo: | Funding Information: This work was supported by EyeFundusScopeNEO: Demonstration of EyeFundusScope with Non-Expert Ophthalmology Users, cofounded by Portugal 2020, framed under the Operational Program Competitiveness and Internationalization (COMPETE 2020) and European Regional Development Fund from European Union, with operation code POCI-01-0247-FEDER-038400. Publisher Copyright: © 2022 by the authors. |
id |
RCAP_4efe16e77746fa294f7d7f685d2aeb2c |
---|---|
oai_identifier_str |
oai:run.unl.pt:10362/159338 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic RetinopathyStudy Protocoldiabetic retinopathydiagnostic accuracyimage qualityinteroperator agreementusabilityMedicine (miscellaneous)Endocrinology, Diabetes and MetabolismInternal MedicineSDG 3 - Good Health and Well-beingFunding Information: This work was supported by EyeFundusScopeNEO: Demonstration of EyeFundusScope with Non-Expert Ophthalmology Users, cofounded by Portugal 2020, framed under the Operational Program Competitiveness and Internationalization (COMPETE 2020) and European Regional Development Fund from European Union, with operation code POCI-01-0247-FEDER-038400. Publisher Copyright: © 2022 by the authors.Screening diabetic retinopathy, a major cause of blindness, is time-consuming for ophthalmologists and has some constrains in achieving full coverage and attendance. The handheld fundus camera EyeFundusScope was recently developed to expand the scale of screening, drawing on images acquired in primary care and telescreening made by ophthalmologists or a computer-aided diagnosis (CADx) system. This study aims to assess the diagnostic accuracy of the interpretation of images captured using EyeFundusScope and perform its technical evaluation, including image quality, functionality, usability, and acceptance in a real-world clinical setting. Physicians and nurses without training in ophthalmology will use EyeFundusScope to take pictures of the retinas of patients with diabetes and the images will be classified for the presence or absence of diabetic retinopathy and image quality by a panel of ophthalmologists. A subgroup of patients will also be examined with the reference standard tabletop fundus camera. Screening results provided by the CADx system on images taken with EyeFundusScope will be compared against the ophthalmologists’ analysis of images taken with the tabletop fundus camera. Diagnostic accuracy measures with 95% confidence intervals (CIs) will be calculated for positive and negative test results. Proportion of each category of image quality will be presented. Usability and acceptance results will be presented qualitatively.NOVA Medical School|Faculdade de Ciências Médicas (NMS|FCM)RUNRêgo, SílviaMonteiro-Soares, MatildeDutra-Medeiros, MarcoSoares, FilipeDias, Cláudia CamilaNunes, Francisco2023-10-27T22:21:47Z2022-032022-03-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article16application/pdfhttp://hdl.handle.net/10362/159338eng2673-4540PURE: 74315825https://doi.org/10.3390/diabetology3010001info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-11T05:41:47Zoai:run.unl.pt:10362/159338Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:57:29.637481Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic Retinopathy Study Protocol |
title |
Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic Retinopathy |
spellingShingle |
Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic Retinopathy Rêgo, Sílvia diabetic retinopathy diagnostic accuracy image quality interoperator agreement usability Medicine (miscellaneous) Endocrinology, Diabetes and Metabolism Internal Medicine SDG 3 - Good Health and Well-being |
title_short |
Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic Retinopathy |
title_full |
Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic Retinopathy |
title_fullStr |
Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic Retinopathy |
title_full_unstemmed |
Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic Retinopathy |
title_sort |
Implementation and Evaluation of a Mobile Retinal Image Acquisition System for Screening Diabetic Retinopathy |
author |
Rêgo, Sílvia |
author_facet |
Rêgo, Sílvia Monteiro-Soares, Matilde Dutra-Medeiros, Marco Soares, Filipe Dias, Cláudia Camila Nunes, Francisco |
author_role |
author |
author2 |
Monteiro-Soares, Matilde Dutra-Medeiros, Marco Soares, Filipe Dias, Cláudia Camila Nunes, Francisco |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
NOVA Medical School|Faculdade de Ciências Médicas (NMS|FCM) RUN |
dc.contributor.author.fl_str_mv |
Rêgo, Sílvia Monteiro-Soares, Matilde Dutra-Medeiros, Marco Soares, Filipe Dias, Cláudia Camila Nunes, Francisco |
dc.subject.por.fl_str_mv |
diabetic retinopathy diagnostic accuracy image quality interoperator agreement usability Medicine (miscellaneous) Endocrinology, Diabetes and Metabolism Internal Medicine SDG 3 - Good Health and Well-being |
topic |
diabetic retinopathy diagnostic accuracy image quality interoperator agreement usability Medicine (miscellaneous) Endocrinology, Diabetes and Metabolism Internal Medicine SDG 3 - Good Health and Well-being |
description |
Funding Information: This work was supported by EyeFundusScopeNEO: Demonstration of EyeFundusScope with Non-Expert Ophthalmology Users, cofounded by Portugal 2020, framed under the Operational Program Competitiveness and Internationalization (COMPETE 2020) and European Regional Development Fund from European Union, with operation code POCI-01-0247-FEDER-038400. Publisher Copyright: © 2022 by the authors. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-03 2022-03-01T00:00:00Z 2023-10-27T22:21:47Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10362/159338 |
url |
http://hdl.handle.net/10362/159338 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2673-4540 PURE: 74315825 https://doi.org/10.3390/diabetology3010001 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
16 application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799138157533331456 |