Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection

Detalhes bibliográficos
Autor(a) principal: Fernandes, L. M. P.
Data de Publicação: 2003
Outros Autores: Antognini, A., Boucher, M., Conde, C. A. N., Huot, O., Knowles, P., Kottmann, F., Ludhova, L., Mulhauser, F., Pohl, R., Schaller, L. A., Santos, J. M. F. dos, Taqqu, D., Veloso, J. F. C. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/4483
https://doi.org/10.1016/S0168-9002(02)02081-8
Resumo: The behaviour of large-area avalanche photodiodes for X-rays, visible and vacuum-ultra-violet (VUV) light detection in magnetic fields up to 5 T is described. For X-rays and visible light detection, the photodiode pulse amplitude and energy resolution were unaffected from 0 to 5 T, demonstrating the insensitivity of this type of detector to strong magnetic fields. For VUV light detection, however, the photodiode relative pulse amplitude decreases with increasing magnetic field intensity reaching a reduction of about 24% at 5 T, and the energy resolution degrades noticeably with increasing magnetic field.
id RCAP_57a12f6791c3204fd327b1aa460fce50
oai_identifier_str oai:estudogeral.uc.pt:10316/4483
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detectionPhoton detectorsX-ray detectionAvalanche photodiodesMagnetic fieldThe behaviour of large-area avalanche photodiodes for X-rays, visible and vacuum-ultra-violet (VUV) light detection in magnetic fields up to 5 T is described. For X-rays and visible light detection, the photodiode pulse amplitude and energy resolution were unaffected from 0 to 5 T, demonstrating the insensitivity of this type of detector to strong magnetic fields. For VUV light detection, however, the photodiode relative pulse amplitude decreases with increasing magnetic field intensity reaching a reduction of about 24% at 5 T, and the energy resolution degrades noticeably with increasing magnetic field.http://www.sciencedirect.com/science/article/B6TJM-47K21KV-1/1/9eb7bcce781352042c63344265f8da972003info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/4483http://hdl.handle.net/10316/4483https://doi.org/10.1016/S0168-9002(02)02081-8engNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 498:1-3 (2003) 362-368Fernandes, L. M. P.Antognini, A.Boucher, M.Conde, C. A. N.Huot, O.Knowles, P.Kottmann, F.Ludhova, L.Mulhauser, F.Pohl, R.Schaller, L. A.Santos, J. M. F. dosTaqqu, D.Veloso, J. F. C. A.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2021-10-22T11:35:52Zoai:estudogeral.uc.pt:10316/4483Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:47.622125Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection
title Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection
spellingShingle Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection
Fernandes, L. M. P.
Photon detectors
X-ray detection
Avalanche photodiodes
Magnetic field
title_short Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection
title_full Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection
title_fullStr Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection
title_full_unstemmed Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection
title_sort Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection
author Fernandes, L. M. P.
author_facet Fernandes, L. M. P.
Antognini, A.
Boucher, M.
Conde, C. A. N.
Huot, O.
Knowles, P.
Kottmann, F.
Ludhova, L.
Mulhauser, F.
Pohl, R.
Schaller, L. A.
Santos, J. M. F. dos
Taqqu, D.
Veloso, J. F. C. A.
author_role author
author2 Antognini, A.
Boucher, M.
Conde, C. A. N.
Huot, O.
Knowles, P.
Kottmann, F.
Ludhova, L.
Mulhauser, F.
Pohl, R.
Schaller, L. A.
Santos, J. M. F. dos
Taqqu, D.
Veloso, J. F. C. A.
author2_role author
author
author
author
author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Fernandes, L. M. P.
Antognini, A.
Boucher, M.
Conde, C. A. N.
Huot, O.
Knowles, P.
Kottmann, F.
Ludhova, L.
Mulhauser, F.
Pohl, R.
Schaller, L. A.
Santos, J. M. F. dos
Taqqu, D.
Veloso, J. F. C. A.
dc.subject.por.fl_str_mv Photon detectors
X-ray detection
Avalanche photodiodes
Magnetic field
topic Photon detectors
X-ray detection
Avalanche photodiodes
Magnetic field
description The behaviour of large-area avalanche photodiodes for X-rays, visible and vacuum-ultra-violet (VUV) light detection in magnetic fields up to 5 T is described. For X-rays and visible light detection, the photodiode pulse amplitude and energy resolution were unaffected from 0 to 5 T, demonstrating the insensitivity of this type of detector to strong magnetic fields. For VUV light detection, however, the photodiode relative pulse amplitude decreases with increasing magnetic field intensity reaching a reduction of about 24% at 5 T, and the energy resolution degrades noticeably with increasing magnetic field.
publishDate 2003
dc.date.none.fl_str_mv 2003
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/4483
http://hdl.handle.net/10316/4483
https://doi.org/10.1016/S0168-9002(02)02081-8
url http://hdl.handle.net/10316/4483
https://doi.org/10.1016/S0168-9002(02)02081-8
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 498:1-3 (2003) 362-368
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv aplication/PDF
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133888895778816