Asthma Management With Breath-Triggered Inhalers: Innovation Through Design
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.17/3772 |
Resumo: | Background: Asthma affects the lives of hundred million people around the World. Despite notable progresses in disease management, asthma control remains largely insufficient worldwide, influencing patients' wellbeing and quality of life. Poor patient handling of inhaling devices has been identified as a major persistent problem that significantly reduces inhaled drugs' efficacy and is associated with poor adherence to treatment, impairing clinical results such as asthma control and increasing disease-related costs. We herein review key research and development (R&D) innovation in inhaler devices, highlighting major real-world critical errors in the handling and inhalation technique with current devices and considering potential solutions. Furthermore, we discuss current evidence regarding breath-triggered inhalers (BTI). Main body: The two most common significant problems with inhalers are coordinating actuation and inhalation with pressurized metered-dose inhalers (pMDIs), and the need to inhale forcibly with a dry powder inhaler. BTI R&D plans were designed to overcome these problems. Its newest device k-haler® has several other important features, generating a less forceful aerosol plume than previous pMDIs, with efficient drug delivery and lung deposition, even in patients with low inspiratory flow. The local and systemic bioavailability of fluticasone propionate and formoterol (FP/FORM) administered via k-haler® has been shown to be therapeutically equivalent when administered via the previous FP/FORM pMDI. This device requires very few steps and has been considered easy to use (even at first attempt) and preferred by the patients in a randomized crossover study. In our country, FP/FORM k-haler is available without additional costs compared to FP/FORM pMDI. All devices continue to require education and regular checking of the correct inhalation technique. Conclusion: BTI R&D can bring advantage over current available inhalers, avoiding the two most common identified critical errors in inhalation technique. K-haler® BTI is currently available, without an increased cost, and approved for adolescents and adults with asthma in whom treatment with inhaled combined therapy with long-acting beta2-agonists and corticosteroids is indicated. Its attractive and practical design to facilitate its use has been awarded. K-haler® represents added value through innovation to fulfill actual asthma patient needs, thus with potential relevant impact in asthma management and effective control. |
id |
RCAP_5ae7fc961691c8acba4d57cc16764ebb |
---|---|
oai_identifier_str |
oai:repositorio.chlc.pt:10400.17/3772 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Asthma Management With Breath-Triggered Inhalers: Innovation Through DesignHSM PNEUAsthmaBreath-triggered-inhalersControlInhalersInnovationK-halerBackground: Asthma affects the lives of hundred million people around the World. Despite notable progresses in disease management, asthma control remains largely insufficient worldwide, influencing patients' wellbeing and quality of life. Poor patient handling of inhaling devices has been identified as a major persistent problem that significantly reduces inhaled drugs' efficacy and is associated with poor adherence to treatment, impairing clinical results such as asthma control and increasing disease-related costs. We herein review key research and development (R&D) innovation in inhaler devices, highlighting major real-world critical errors in the handling and inhalation technique with current devices and considering potential solutions. Furthermore, we discuss current evidence regarding breath-triggered inhalers (BTI). Main body: The two most common significant problems with inhalers are coordinating actuation and inhalation with pressurized metered-dose inhalers (pMDIs), and the need to inhale forcibly with a dry powder inhaler. BTI R&D plans were designed to overcome these problems. Its newest device k-haler® has several other important features, generating a less forceful aerosol plume than previous pMDIs, with efficient drug delivery and lung deposition, even in patients with low inspiratory flow. The local and systemic bioavailability of fluticasone propionate and formoterol (FP/FORM) administered via k-haler® has been shown to be therapeutically equivalent when administered via the previous FP/FORM pMDI. This device requires very few steps and has been considered easy to use (even at first attempt) and preferred by the patients in a randomized crossover study. In our country, FP/FORM k-haler is available without additional costs compared to FP/FORM pMDI. All devices continue to require education and regular checking of the correct inhalation technique. Conclusion: BTI R&D can bring advantage over current available inhalers, avoiding the two most common identified critical errors in inhalation technique. K-haler® BTI is currently available, without an increased cost, and approved for adolescents and adults with asthma in whom treatment with inhaled combined therapy with long-acting beta2-agonists and corticosteroids is indicated. Its attractive and practical design to facilitate its use has been awarded. K-haler® represents added value through innovation to fulfill actual asthma patient needs, thus with potential relevant impact in asthma management and effective control.BMCRepositório do Centro Hospitalar Universitário de Lisboa Central, EPEMorais-Almeida, MPité, HCardoso, JCosta, RRobalo Cordeiro, CSilva, ETodo-Bom, AVicente, CMarques, JA2021-07-16T13:15:08Z20202020-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/3772engAsthma Res Pract. 2020 Jun 6;6:4.10.1186/s40733-020-00057-7info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-10-28T10:29:40Zoai:repositorio.chlc.pt:10400.17/3772Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-10-28T10:29:40Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Asthma Management With Breath-Triggered Inhalers: Innovation Through Design |
title |
Asthma Management With Breath-Triggered Inhalers: Innovation Through Design |
spellingShingle |
Asthma Management With Breath-Triggered Inhalers: Innovation Through Design Morais-Almeida, M HSM PNEU Asthma Breath-triggered-inhalers Control Inhalers Innovation K-haler |
title_short |
Asthma Management With Breath-Triggered Inhalers: Innovation Through Design |
title_full |
Asthma Management With Breath-Triggered Inhalers: Innovation Through Design |
title_fullStr |
Asthma Management With Breath-Triggered Inhalers: Innovation Through Design |
title_full_unstemmed |
Asthma Management With Breath-Triggered Inhalers: Innovation Through Design |
title_sort |
Asthma Management With Breath-Triggered Inhalers: Innovation Through Design |
author |
Morais-Almeida, M |
author_facet |
Morais-Almeida, M Pité, H Cardoso, J Costa, R Robalo Cordeiro, C Silva, E Todo-Bom, A Vicente, C Marques, JA |
author_role |
author |
author2 |
Pité, H Cardoso, J Costa, R Robalo Cordeiro, C Silva, E Todo-Bom, A Vicente, C Marques, JA |
author2_role |
author author author author author author author author |
dc.contributor.none.fl_str_mv |
Repositório do Centro Hospitalar Universitário de Lisboa Central, EPE |
dc.contributor.author.fl_str_mv |
Morais-Almeida, M Pité, H Cardoso, J Costa, R Robalo Cordeiro, C Silva, E Todo-Bom, A Vicente, C Marques, JA |
dc.subject.por.fl_str_mv |
HSM PNEU Asthma Breath-triggered-inhalers Control Inhalers Innovation K-haler |
topic |
HSM PNEU Asthma Breath-triggered-inhalers Control Inhalers Innovation K-haler |
description |
Background: Asthma affects the lives of hundred million people around the World. Despite notable progresses in disease management, asthma control remains largely insufficient worldwide, influencing patients' wellbeing and quality of life. Poor patient handling of inhaling devices has been identified as a major persistent problem that significantly reduces inhaled drugs' efficacy and is associated with poor adherence to treatment, impairing clinical results such as asthma control and increasing disease-related costs. We herein review key research and development (R&D) innovation in inhaler devices, highlighting major real-world critical errors in the handling and inhalation technique with current devices and considering potential solutions. Furthermore, we discuss current evidence regarding breath-triggered inhalers (BTI). Main body: The two most common significant problems with inhalers are coordinating actuation and inhalation with pressurized metered-dose inhalers (pMDIs), and the need to inhale forcibly with a dry powder inhaler. BTI R&D plans were designed to overcome these problems. Its newest device k-haler® has several other important features, generating a less forceful aerosol plume than previous pMDIs, with efficient drug delivery and lung deposition, even in patients with low inspiratory flow. The local and systemic bioavailability of fluticasone propionate and formoterol (FP/FORM) administered via k-haler® has been shown to be therapeutically equivalent when administered via the previous FP/FORM pMDI. This device requires very few steps and has been considered easy to use (even at first attempt) and preferred by the patients in a randomized crossover study. In our country, FP/FORM k-haler is available without additional costs compared to FP/FORM pMDI. All devices continue to require education and regular checking of the correct inhalation technique. Conclusion: BTI R&D can bring advantage over current available inhalers, avoiding the two most common identified critical errors in inhalation technique. K-haler® BTI is currently available, without an increased cost, and approved for adolescents and adults with asthma in whom treatment with inhaled combined therapy with long-acting beta2-agonists and corticosteroids is indicated. Its attractive and practical design to facilitate its use has been awarded. K-haler® represents added value through innovation to fulfill actual asthma patient needs, thus with potential relevant impact in asthma management and effective control. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020 2020-01-01T00:00:00Z 2021-07-16T13:15:08Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.17/3772 |
url |
http://hdl.handle.net/10400.17/3772 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Asthma Res Pract. 2020 Jun 6;6:4. 10.1186/s40733-020-00057-7 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
BMC |
publisher.none.fl_str_mv |
BMC |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
mluisa.alvim@gmail.com |
_version_ |
1817548654358036480 |