Factors related to the incorrect use of inhalers by asthma patients

Detalhes bibliográficos
Autor(a) principal: Dalcin,Paulo de Tarso Roth
Data de Publicação: 2014
Outros Autores: Grutcki,Denis Maltz, Laporte,Paola Paganella, Lima,Paula Borges de, Menegotto,Samuel Millan, Pereira,Rosemary Petrik
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Jornal Brasileiro de Pneumologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132014000100013
Resumo: OBJECTIVE: To evaluate inhaler technique in outpatients with asthma and to determine associations between the correctness of that technique and the level of asthma control. METHODS: This was a cross-sectional study involving patients > 14 years of age with physician-diagnosed asthma. The patients were recruited from the Asthma Outpatient Clinic of the Hospital de Clínicas de Porto Alegre, in the city of Porto Alegre, Brazil. The patients completed two questionnaires (a general questionnaire and an asthma control questionnaire based on the 2011 Global Initiative for Asthma guidelines), demonstrated their inhaler technique, and performed pulmonary function tests. Incorrect inhaler technique was defined as the incorrect execution of at least two of the predefined steps. RESULTS: We included 268 patients. Of those, 81 (30.2%) showed incorrect inhaler technique, which was associated with poor asthma control (p = 0.002). Logistic regression analysis identified the following factors associated with incorrect inhaler technique: being widowed (OR = 5.01; 95% CI, 1.74-14.41; p = 0.003); using metered dose inhalers (OR = 1.58; 95% CI, 1.35-1.85; p < 0.001); having a monthly family income < 3 times the minimum wage (OR = 2.67; 95% CI, 1.35-1.85; p = 0.008), and having > 2 comorbidities (OR = 3.80; 95% CI, 1.03-14.02; p = 0.045). CONCLUSIONS: In the sample studied, incorrect inhaler technique was associated with poor asthma control. Widowhood, use of metered dose inhalers, low socioeconomic level, and the presence of > 2 comorbidities were associated with incorrect inhaler technique.
id SBPT-1_77cfa51a2711ca1617706c83fdfd639b
oai_identifier_str oai:scielo:S1806-37132014000100013
network_acronym_str SBPT-1
network_name_str Jornal Brasileiro de Pneumologia (Online)
repository_id_str
spelling Factors related to the incorrect use of inhalers by asthma patientsMetered dose inhalersDry powder inhalersAsthma/therapy OBJECTIVE: To evaluate inhaler technique in outpatients with asthma and to determine associations between the correctness of that technique and the level of asthma control. METHODS: This was a cross-sectional study involving patients > 14 years of age with physician-diagnosed asthma. The patients were recruited from the Asthma Outpatient Clinic of the Hospital de Clínicas de Porto Alegre, in the city of Porto Alegre, Brazil. The patients completed two questionnaires (a general questionnaire and an asthma control questionnaire based on the 2011 Global Initiative for Asthma guidelines), demonstrated their inhaler technique, and performed pulmonary function tests. Incorrect inhaler technique was defined as the incorrect execution of at least two of the predefined steps. RESULTS: We included 268 patients. Of those, 81 (30.2%) showed incorrect inhaler technique, which was associated with poor asthma control (p = 0.002). Logistic regression analysis identified the following factors associated with incorrect inhaler technique: being widowed (OR = 5.01; 95% CI, 1.74-14.41; p = 0.003); using metered dose inhalers (OR = 1.58; 95% CI, 1.35-1.85; p < 0.001); having a monthly family income < 3 times the minimum wage (OR = 2.67; 95% CI, 1.35-1.85; p = 0.008), and having > 2 comorbidities (OR = 3.80; 95% CI, 1.03-14.02; p = 0.045). CONCLUSIONS: In the sample studied, incorrect inhaler technique was associated with poor asthma control. Widowhood, use of metered dose inhalers, low socioeconomic level, and the presence of > 2 comorbidities were associated with incorrect inhaler technique. Sociedade Brasileira de Pneumologia e Tisiologia2014-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132014000100013Jornal Brasileiro de Pneumologia v.40 n.1 2014reponame:Jornal Brasileiro de Pneumologia (Online)instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)instacron:SBPT10.1590/S1806-37132014000100003info:eu-repo/semantics/openAccessDalcin,Paulo de Tarso RothGrutcki,Denis MaltzLaporte,Paola PaganellaLima,Paula Borges deMenegotto,Samuel MillanPereira,Rosemary Petrikeng2014-03-20T00:00:00Zoai:scielo:S1806-37132014000100013Revistahttp://www.jornaldepneumologia.com.br/default.aspONGhttps://old.scielo.br/oai/scielo-oai.php||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br1806-37561806-3713opendoar:2014-03-20T00:00Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)false
dc.title.none.fl_str_mv Factors related to the incorrect use of inhalers by asthma patients
title Factors related to the incorrect use of inhalers by asthma patients
spellingShingle Factors related to the incorrect use of inhalers by asthma patients
Dalcin,Paulo de Tarso Roth
Metered dose inhalers
Dry powder inhalers
Asthma/therapy
title_short Factors related to the incorrect use of inhalers by asthma patients
title_full Factors related to the incorrect use of inhalers by asthma patients
title_fullStr Factors related to the incorrect use of inhalers by asthma patients
title_full_unstemmed Factors related to the incorrect use of inhalers by asthma patients
title_sort Factors related to the incorrect use of inhalers by asthma patients
author Dalcin,Paulo de Tarso Roth
author_facet Dalcin,Paulo de Tarso Roth
Grutcki,Denis Maltz
Laporte,Paola Paganella
Lima,Paula Borges de
Menegotto,Samuel Millan
Pereira,Rosemary Petrik
author_role author
author2 Grutcki,Denis Maltz
Laporte,Paola Paganella
Lima,Paula Borges de
Menegotto,Samuel Millan
Pereira,Rosemary Petrik
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Dalcin,Paulo de Tarso Roth
Grutcki,Denis Maltz
Laporte,Paola Paganella
Lima,Paula Borges de
Menegotto,Samuel Millan
Pereira,Rosemary Petrik
dc.subject.por.fl_str_mv Metered dose inhalers
Dry powder inhalers
Asthma/therapy
topic Metered dose inhalers
Dry powder inhalers
Asthma/therapy
description OBJECTIVE: To evaluate inhaler technique in outpatients with asthma and to determine associations between the correctness of that technique and the level of asthma control. METHODS: This was a cross-sectional study involving patients > 14 years of age with physician-diagnosed asthma. The patients were recruited from the Asthma Outpatient Clinic of the Hospital de Clínicas de Porto Alegre, in the city of Porto Alegre, Brazil. The patients completed two questionnaires (a general questionnaire and an asthma control questionnaire based on the 2011 Global Initiative for Asthma guidelines), demonstrated their inhaler technique, and performed pulmonary function tests. Incorrect inhaler technique was defined as the incorrect execution of at least two of the predefined steps. RESULTS: We included 268 patients. Of those, 81 (30.2%) showed incorrect inhaler technique, which was associated with poor asthma control (p = 0.002). Logistic regression analysis identified the following factors associated with incorrect inhaler technique: being widowed (OR = 5.01; 95% CI, 1.74-14.41; p = 0.003); using metered dose inhalers (OR = 1.58; 95% CI, 1.35-1.85; p < 0.001); having a monthly family income < 3 times the minimum wage (OR = 2.67; 95% CI, 1.35-1.85; p = 0.008), and having > 2 comorbidities (OR = 3.80; 95% CI, 1.03-14.02; p = 0.045). CONCLUSIONS: In the sample studied, incorrect inhaler technique was associated with poor asthma control. Widowhood, use of metered dose inhalers, low socioeconomic level, and the presence of > 2 comorbidities were associated with incorrect inhaler technique.
publishDate 2014
dc.date.none.fl_str_mv 2014-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132014000100013
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132014000100013
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-37132014000100003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pneumologia e Tisiologia
publisher.none.fl_str_mv Sociedade Brasileira de Pneumologia e Tisiologia
dc.source.none.fl_str_mv Jornal Brasileiro de Pneumologia v.40 n.1 2014
reponame:Jornal Brasileiro de Pneumologia (Online)
instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
instacron:SBPT
instname_str Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
instacron_str SBPT
institution SBPT
reponame_str Jornal Brasileiro de Pneumologia (Online)
collection Jornal Brasileiro de Pneumologia (Online)
repository.name.fl_str_mv Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
repository.mail.fl_str_mv ||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br
_version_ 1750318345871163392