Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable device

Detalhes bibliográficos
Autor(a) principal: Gonçalves, Vanessa Matos
Data de Publicação: 2022
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/1822/77766
Resumo: Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)
id RCAP_5dd0a477c0a473dbfe2a3d33da952e7f
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/77766
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable deviceBiossensorDeteção eletroquímicaLAMP em tempo realTestes de amplificação de ácidos núcleicosBiosensorElectrochemical detectionNucleic acid amplification testsReal-time LAMPEngenharia e Tecnologia::Engenharia MédicaDissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)Nos últimos anos os biossensores eletroquímicos têm sido reportados como uma abordagem promis sora para a deteção de DNA. São atrativos para dispositivos point-of-care pela facilidade de miniaturização, compatibilidade com técnicas de microfabricação e facilidade de instrumentação. Contudo, a integração de uma fase de amplificação com a deteção de sinais continua a ser um desafio. A técnica LAMP (loop mediated isothermal amplification ) surgiu como solução, destacando-se pela sua robustez e sensibilidade. Uma plataforma portátil para deteção eletroquímica de DNA (Mobi-E) foi desenvolvida para incorporar as caraterísticas mencionadas. Neste trabalho foram caraterizados os principais componentes do disposi tivo: potencióstatos ASIC, controlo de temperatura e um chip fluídico que integra elétrodos e estruturas de aquecimento impressas. Seguidamente, efetuou-se uma pesquisa para funcionalização universal desses elétrodos utilizando MD LAMP (mediator displacement LAMP). O desempenho do potencióstato, especificamente a rotina de voltametria de onda quadrada e a leitura quase simultânea dos 6 elétrodos de trabalho de uma câmara, foi provado e comparado com um dispositivo comercial, obtendo-se resultados qualitativamente comparáveis. Foram ainda realizadas otimizações para estabilização do potencial de referência, através da conversão Ag/AgCl por FeCl3, e para precaver dificuldades de medição resultantes da limitada tensão de conformidade do potencióstato (1.8 V). Para tal, aumentou-se a área do elétrodo auxiliar, através da impressão de 8 camadas de Au (4 no elétrodo de trabalho), e efetuou-se, entre medições, o curto-circuito entre o elétrodo auxiliar e o de referência. O sistema de controlo de temperatura provou ser efetivo no aquecimento das câmaras até 65 ºC em 2.5 min e na monitorização assertiva das suas temperaturas. Não foi detetado cross-talk entre câmaras vizinhas, nem a formação severa de bolhas de ar. Como prova de conceito, foram testadas quatro abordagens para MD LAMP e foi identificada uma alternativa promissora (Stem-Loop ) ao standard, com a respetiva mudança relativa de sinal: 0.3 e 177.6. Esta dissertação culmina com a otimização da reação LAMP para uma libertação eficiente do medi ador. Duas promissoras combinações de concentrações de mediador, primer modificado e loop primer foram identificadas: 200 nM, 400 nM, 400 nM e 100 nM, 200 nM, 600 nM, respetivamente, obtendo-se uma relação sinal/ruído de 3.7 e 2.9. Os conhecimentos adquiridos viabilizam o avanço da investigação no sentido da obtenção de um dispositivo capaz de realizar LAMP eletroquímico em tempo real.Electrochemical biosensors have been reported in recent years as a promising approach for DNA detection. The ease of miniaturization, compatibility with microfabrication techniques and simple instru mentation make these sensors attractive for point-of-care (POC) devices. However, integrating an ampli fication stage with signal detection remains a challenge. Loop-mediated isothermal amplification (LAMP) has emerged as a robust and highly sensitive isothermal strategy. A novel portable platform for rapid electrochemical DNA detection (Mobi-E device) was developed to incorporate the aforementioned features. Within this work, an extensive characterization of the main components of the Mobi-E device, which comprises ASIC potentiostats, temperature control, and a fluidic chip with integrated inkjet-printed electrodes and heating structures, was performed, followed by a research towards target-independent electrode functionalization employing mediator displacement (MD) LAMP. The operation of the general functionalities of the ASIC potentiostat, specifically the square wave voltammetry (SWV) routine and the quasi-simultaneous read-out of all 6 working electrodes (WEs) of a chamber, was proven and its performance was benchmarked against a commercial device, achieving qualitatively comparable results. Inherent optimizations of the device were performed to stabilize the reference electrode (RE) potential, through Ag/AgCl conversion by FeCl3, and to address the criticality that the 1.8 V compliance voltage of the potentiostat brought to the measurements. For this issue, it is suggested to increase the counter electrode (CE) area by printing 8 Au layers (WE with 4 layers) and to short-circuit the CE and RE between measurements. The temperature control system proved to be effective in heating the chambers to 65 ºC in about 2.5 min and assertively monitoring their temperature. Furthermore, no cross-talk between neighbouring chambers and no severe bubble formation was detected. Four concepts for target-independent MD LAMP were tested as proof-of-concept and a promising alternative (”Stem-Loop universal reporter (UR)”) to the standard approach was identified. The following relative signal change was achieved: 0.3 and 177.6, respectively. This thesis culminates with the optimization of fluorescent LAMP reaction parameters towards an efficient mediator release. Two promising concentration combinations of mediator, modified primer (LB_Medc) and loop primer (LB) were identified: 200 nM, 400 nM, 400 nM and 100 nM, 200 nM, 600 nM, respectively. For these, the signal-to-noise ratio was 3.7 and 2.9. The knowledge acquired in this thesis allows moving forward towards a device able to perform electrochemical real-time LAMP readout.Minas, GraçaStetten, Felix vonUniversidade do MinhoGonçalves, Vanessa Matos2022-02-112022-02-11T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttps://hdl.handle.net/1822/77766eng202978184info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:54:35Zoai:repositorium.sdum.uminho.pt:1822/77766Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:54:11.281331Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable device
title Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable device
spellingShingle Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable device
Gonçalves, Vanessa Matos
Biossensor
Deteção eletroquímica
LAMP em tempo real
Testes de amplificação de ácidos núcleicos
Biosensor
Electrochemical detection
Nucleic acid amplification tests
Real-time LAMP
Engenharia e Tecnologia::Engenharia Médica
title_short Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable device
title_full Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable device
title_fullStr Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable device
title_full_unstemmed Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable device
title_sort Characterization and development towards electrochemical real-time LAMP detection in an integrated and portable device
author Gonçalves, Vanessa Matos
author_facet Gonçalves, Vanessa Matos
author_role author
dc.contributor.none.fl_str_mv Minas, Graça
Stetten, Felix von
Universidade do Minho
dc.contributor.author.fl_str_mv Gonçalves, Vanessa Matos
dc.subject.por.fl_str_mv Biossensor
Deteção eletroquímica
LAMP em tempo real
Testes de amplificação de ácidos núcleicos
Biosensor
Electrochemical detection
Nucleic acid amplification tests
Real-time LAMP
Engenharia e Tecnologia::Engenharia Médica
topic Biossensor
Deteção eletroquímica
LAMP em tempo real
Testes de amplificação de ácidos núcleicos
Biosensor
Electrochemical detection
Nucleic acid amplification tests
Real-time LAMP
Engenharia e Tecnologia::Engenharia Médica
description Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)
publishDate 2022
dc.date.none.fl_str_mv 2022-02-11
2022-02-11T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/77766
url https://hdl.handle.net/1822/77766
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 202978184
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133140012236800