Texto Completo: https://hdl.handle.net/10216/67541
Resumo: The present communication focuses on the importance of the dynamic actions induced by groups of people with synchronous movements and the need to perform dynamic analysis in the corresponding structural elements. Special attention herein is given to the case of stadium structures. The continuous optimization in structural design made possible, in certain cases, to resist to high loading values in ultimate limit states but still have serviceability deficiencies. Problems with excessive vibration on recently built structures have been reported (SCOSS 2001). This can cause human discomfort, crowd panic or collapse of the structure. Simple methods like adopting a frequency threshold cannot always be applied since they may result in a substantial increment in cost or are impossible to accomplish due to architectural constraints. This is the reason why it is unavoidably necessary to model and evaluate the dynamic response of certain structures. This article presents also some results of the monitoring of two events in a grandstand on Dragon Stadium in operating conditions.
id RCAP_5eb70c10fb0204cebb0c15515e9d9b51
oai_identifier_str oai:repositorio-aberto.up.pt:10216/67541
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Vibration monitoring of a grandstand in Dragon StadiumEngenharia estrutural, Engenharia civilStructural engineering, Civil engineeringThe present communication focuses on the importance of the dynamic actions induced by groups of people with synchronous movements and the need to perform dynamic analysis in the corresponding structural elements. Special attention herein is given to the case of stadium structures. The continuous optimization in structural design made possible, in certain cases, to resist to high loading values in ultimate limit states but still have serviceability deficiencies. Problems with excessive vibration on recently built structures have been reported (SCOSS 2001). This can cause human discomfort, crowd panic or collapse of the structure. Simple methods like adopting a frequency threshold cannot always be applied since they may result in a substantial increment in cost or are impossible to accomplish due to architectural constraints. This is the reason why it is unavoidably necessary to model and evaluate the dynamic response of certain structures. This article presents also some results of the monitoring of two events in a grandstand on Dragon Stadium in operating conditions.20072007-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bookapplication/pdfhttps://hdl.handle.net/10216/67541engH. MarquesA. ArêdeR. M. Delgadoinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-29T15:01:13Zoai:repositorio-aberto.up.pt:10216/67541Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:13:47.384434Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Vibration monitoring of a grandstand in Dragon Stadium
title Vibration monitoring of a grandstand in Dragon Stadium
spellingShingle Vibration monitoring of a grandstand in Dragon Stadium
H. Marques
Engenharia estrutural, Engenharia civil
Structural engineering, Civil engineering
title_short Vibration monitoring of a grandstand in Dragon Stadium
title_full Vibration monitoring of a grandstand in Dragon Stadium
title_fullStr Vibration monitoring of a grandstand in Dragon Stadium
title_full_unstemmed Vibration monitoring of a grandstand in Dragon Stadium
title_sort Vibration monitoring of a grandstand in Dragon Stadium
author H. Marques
author_facet H. Marques
A. Arêde
R. M. Delgado
author_role author
author2 A. Arêde
R. M. Delgado
author2_role author
author
dc.contributor.author.fl_str_mv H. Marques
A. Arêde
R. M. Delgado
dc.subject.por.fl_str_mv Engenharia estrutural, Engenharia civil
Structural engineering, Civil engineering
topic Engenharia estrutural, Engenharia civil
Structural engineering, Civil engineering
description The present communication focuses on the importance of the dynamic actions induced by groups of people with synchronous movements and the need to perform dynamic analysis in the corresponding structural elements. Special attention herein is given to the case of stadium structures. The continuous optimization in structural design made possible, in certain cases, to resist to high loading values in ultimate limit states but still have serviceability deficiencies. Problems with excessive vibration on recently built structures have been reported (SCOSS 2001). This can cause human discomfort, crowd panic or collapse of the structure. Simple methods like adopting a frequency threshold cannot always be applied since they may result in a substantial increment in cost or are impossible to accomplish due to architectural constraints. This is the reason why it is unavoidably necessary to model and evaluate the dynamic response of certain structures. This article presents also some results of the monitoring of two events in a grandstand on Dragon Stadium in operating conditions.
publishDate 2007
dc.date.none.fl_str_mv 2007
2007-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/book
format book
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10216/67541
url https://hdl.handle.net/10216/67541
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136059692417024