Vibration monitoring of a grandstand in Dragon Stadium
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , |
Tipo de documento: | Livro |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://hdl.handle.net/10216/67541 |
Resumo: | The present communication focuses on the importance of the dynamic actions induced by groups of people with synchronous movements and the need to perform dynamic analysis in the corresponding structural elements. Special attention herein is given to the case of stadium structures. The continuous optimization in structural design made possible, in certain cases, to resist to high loading values in ultimate limit states but still have serviceability deficiencies. Problems with excessive vibration on recently built structures have been reported (SCOSS 2001). This can cause human discomfort, crowd panic or collapse of the structure. Simple methods like adopting a frequency threshold cannot always be applied since they may result in a substantial increment in cost or are impossible to accomplish due to architectural constraints. This is the reason why it is unavoidably necessary to model and evaluate the dynamic response of certain structures. This article presents also some results of the monitoring of two events in a grandstand on Dragon Stadium in operating conditions. |
id |
RCAP_5eb70c10fb0204cebb0c15515e9d9b51 |
---|---|
oai_identifier_str |
oai:repositorio-aberto.up.pt:10216/67541 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Vibration monitoring of a grandstand in Dragon StadiumEngenharia estrutural, Engenharia civilStructural engineering, Civil engineeringThe present communication focuses on the importance of the dynamic actions induced by groups of people with synchronous movements and the need to perform dynamic analysis in the corresponding structural elements. Special attention herein is given to the case of stadium structures. The continuous optimization in structural design made possible, in certain cases, to resist to high loading values in ultimate limit states but still have serviceability deficiencies. Problems with excessive vibration on recently built structures have been reported (SCOSS 2001). This can cause human discomfort, crowd panic or collapse of the structure. Simple methods like adopting a frequency threshold cannot always be applied since they may result in a substantial increment in cost or are impossible to accomplish due to architectural constraints. This is the reason why it is unavoidably necessary to model and evaluate the dynamic response of certain structures. This article presents also some results of the monitoring of two events in a grandstand on Dragon Stadium in operating conditions.20072007-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bookapplication/pdfhttps://hdl.handle.net/10216/67541engH. MarquesA. ArêdeR. M. Delgadoinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-29T15:01:13Zoai:repositorio-aberto.up.pt:10216/67541Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:13:47.384434Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Vibration monitoring of a grandstand in Dragon Stadium |
title |
Vibration monitoring of a grandstand in Dragon Stadium |
spellingShingle |
Vibration monitoring of a grandstand in Dragon Stadium H. Marques Engenharia estrutural, Engenharia civil Structural engineering, Civil engineering |
title_short |
Vibration monitoring of a grandstand in Dragon Stadium |
title_full |
Vibration monitoring of a grandstand in Dragon Stadium |
title_fullStr |
Vibration monitoring of a grandstand in Dragon Stadium |
title_full_unstemmed |
Vibration monitoring of a grandstand in Dragon Stadium |
title_sort |
Vibration monitoring of a grandstand in Dragon Stadium |
author |
H. Marques |
author_facet |
H. Marques A. Arêde R. M. Delgado |
author_role |
author |
author2 |
A. Arêde R. M. Delgado |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
H. Marques A. Arêde R. M. Delgado |
dc.subject.por.fl_str_mv |
Engenharia estrutural, Engenharia civil Structural engineering, Civil engineering |
topic |
Engenharia estrutural, Engenharia civil Structural engineering, Civil engineering |
description |
The present communication focuses on the importance of the dynamic actions induced by groups of people with synchronous movements and the need to perform dynamic analysis in the corresponding structural elements. Special attention herein is given to the case of stadium structures. The continuous optimization in structural design made possible, in certain cases, to resist to high loading values in ultimate limit states but still have serviceability deficiencies. Problems with excessive vibration on recently built structures have been reported (SCOSS 2001). This can cause human discomfort, crowd panic or collapse of the structure. Simple methods like adopting a frequency threshold cannot always be applied since they may result in a substantial increment in cost or are impossible to accomplish due to architectural constraints. This is the reason why it is unavoidably necessary to model and evaluate the dynamic response of certain structures. This article presents also some results of the monitoring of two events in a grandstand on Dragon Stadium in operating conditions. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007 2007-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/book |
format |
book |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/10216/67541 |
url |
https://hdl.handle.net/10216/67541 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799136059692417024 |