Accuracy and repeatability of a new portable ultrasound pachymeter
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/6199 |
Resumo: | To assess the accuracy and repeatability of central corneal thickness (CCT) measurements taken with a new portable ultrasound (US) pachymeter. Methods: Central thickness measurements were taken with a portable pachymeter (SP-100 Handy;Tomey, Nagoya, Japan) and a conventional US pachymeter (Nidek UP-1000; Nidek Technologies, Gamagori, Japan) from 57 right corneas of 57 young adults (19 males, 38 females) aged 18–44 years (mean ± S.D., 22.95 ± 3.92). Three repeated measures were obtained and then compared to obtain the repeatability of each instrument and the agreement between the pachymeters. The three readings taken with the portable pachymeter were compared against each other in order to evaluate intra-session repeatability and bias of each individual measurement with respect to the mean of three. Results: Mean values of CCT were 537 ± 35 micron for conventional and 534 ± 35 micron for the new portable pachymeter. A high agreement was found between the two instruments mean difference = 2.58 micron; 95% CI 1.41–3.75 micron) with only two eyes presenting differences larger than ± 8.6 micron which represents 95% CI in the Bland-Altman plots which represents 1.6% of the mean CCT. The first reading taken showed the highest agreement with the mean value for the portable pachymeter. Conclusions: The instrument tested in this study is able to take reliable measurements of corneal thickness even if a single reading is considered. Intra-session repeatability was very high, as was also the agreement between the average of three readings taken with the two US pachymeters. |
id |
RCAP_5fe486f6169488b34b0292536ee22013 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/6199 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Accuracy and repeatability of a new portable ultrasound pachymeterPachymeter comparisonPortable ultrasound pachymetryCorneal thicknessTo assess the accuracy and repeatability of central corneal thickness (CCT) measurements taken with a new portable ultrasound (US) pachymeter. Methods: Central thickness measurements were taken with a portable pachymeter (SP-100 Handy;Tomey, Nagoya, Japan) and a conventional US pachymeter (Nidek UP-1000; Nidek Technologies, Gamagori, Japan) from 57 right corneas of 57 young adults (19 males, 38 females) aged 18–44 years (mean ± S.D., 22.95 ± 3.92). Three repeated measures were obtained and then compared to obtain the repeatability of each instrument and the agreement between the pachymeters. The three readings taken with the portable pachymeter were compared against each other in order to evaluate intra-session repeatability and bias of each individual measurement with respect to the mean of three. Results: Mean values of CCT were 537 ± 35 micron for conventional and 534 ± 35 micron for the new portable pachymeter. A high agreement was found between the two instruments mean difference = 2.58 micron; 95% CI 1.41–3.75 micron) with only two eyes presenting differences larger than ± 8.6 micron which represents 95% CI in the Bland-Altman plots which represents 1.6% of the mean CCT. The first reading taken showed the highest agreement with the mean value for the portable pachymeter. Conclusions: The instrument tested in this study is able to take reliable measurements of corneal thickness even if a single reading is considered. Intra-session repeatability was very high, as was also the agreement between the average of three readings taken with the two US pachymeters.WileyUniversidade do MinhoQueirós, A.González-Méijome, José ManuelFernandes, Paulo RodriguesJorge, JorgeAlmeida, José B.Parafita, Manuel A.2007-032007-03-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/6199eng"Ophthalmic and physiological optics". ISSN 0275-5408. 27:2 (Mar. 2007) 190-193.0275-5408info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:11:37Zoai:repositorium.sdum.uminho.pt:1822/6199Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:03:25.418098Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Accuracy and repeatability of a new portable ultrasound pachymeter |
title |
Accuracy and repeatability of a new portable ultrasound pachymeter |
spellingShingle |
Accuracy and repeatability of a new portable ultrasound pachymeter Queirós, A. Pachymeter comparison Portable ultrasound pachymetry Corneal thickness |
title_short |
Accuracy and repeatability of a new portable ultrasound pachymeter |
title_full |
Accuracy and repeatability of a new portable ultrasound pachymeter |
title_fullStr |
Accuracy and repeatability of a new portable ultrasound pachymeter |
title_full_unstemmed |
Accuracy and repeatability of a new portable ultrasound pachymeter |
title_sort |
Accuracy and repeatability of a new portable ultrasound pachymeter |
author |
Queirós, A. |
author_facet |
Queirós, A. González-Méijome, José Manuel Fernandes, Paulo Rodrigues Jorge, Jorge Almeida, José B. Parafita, Manuel A. |
author_role |
author |
author2 |
González-Méijome, José Manuel Fernandes, Paulo Rodrigues Jorge, Jorge Almeida, José B. Parafita, Manuel A. |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Queirós, A. González-Méijome, José Manuel Fernandes, Paulo Rodrigues Jorge, Jorge Almeida, José B. Parafita, Manuel A. |
dc.subject.por.fl_str_mv |
Pachymeter comparison Portable ultrasound pachymetry Corneal thickness |
topic |
Pachymeter comparison Portable ultrasound pachymetry Corneal thickness |
description |
To assess the accuracy and repeatability of central corneal thickness (CCT) measurements taken with a new portable ultrasound (US) pachymeter. Methods: Central thickness measurements were taken with a portable pachymeter (SP-100 Handy;Tomey, Nagoya, Japan) and a conventional US pachymeter (Nidek UP-1000; Nidek Technologies, Gamagori, Japan) from 57 right corneas of 57 young adults (19 males, 38 females) aged 18–44 years (mean ± S.D., 22.95 ± 3.92). Three repeated measures were obtained and then compared to obtain the repeatability of each instrument and the agreement between the pachymeters. The three readings taken with the portable pachymeter were compared against each other in order to evaluate intra-session repeatability and bias of each individual measurement with respect to the mean of three. Results: Mean values of CCT were 537 ± 35 micron for conventional and 534 ± 35 micron for the new portable pachymeter. A high agreement was found between the two instruments mean difference = 2.58 micron; 95% CI 1.41–3.75 micron) with only two eyes presenting differences larger than ± 8.6 micron which represents 95% CI in the Bland-Altman plots which represents 1.6% of the mean CCT. The first reading taken showed the highest agreement with the mean value for the portable pachymeter. Conclusions: The instrument tested in this study is able to take reliable measurements of corneal thickness even if a single reading is considered. Intra-session repeatability was very high, as was also the agreement between the average of three readings taken with the two US pachymeters. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-03 2007-03-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/6199 |
url |
http://hdl.handle.net/1822/6199 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
"Ophthalmic and physiological optics". ISSN 0275-5408. 27:2 (Mar. 2007) 190-193. 0275-5408 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Wiley |
publisher.none.fl_str_mv |
Wiley |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132440522915840 |