PET imaging in breast cancer diagnostics

Detalhes bibliográficos
Autor(a) principal: Varela, J.
Data de Publicação: 2007
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://proa.ua.pt/index.php/revdeti/article/view/17121
Resumo: A scanner for positron emission mammography is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes (APD) and readout by a fast low-noise electronic system. A dedicated digital trigger and data acquisition system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla.
id RCAP_6a36aa6af5b13cb9153c0ec587d5fd4a
oai_identifier_str oai:proa.ua.pt:article/17121
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling PET imaging in breast cancer diagnosticsA scanner for positron emission mammography is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes (APD) and readout by a fast low-noise electronic system. A dedicated digital trigger and data acquisition system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla.Apresenta-se um equipamento de imagem por tomografia de emissão de positrões. O detector baseia-se em cristais de LYSO acoplados opticamente a foto díodos de avalanche (APD) lidos por um sistema electrónico de baixo ruído. Um sistema de aquisição de dados dedicado é utilizada para seleccionar coincidências com elevada eficiência, grande banda-passante e reduzido tempo morto. Um manipulador especializado permite realizar exames da glândula mamária e da axila.UA Editora2007-01-01T00:00:00Zconference objectconference objectinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://proa.ua.pt/index.php/revdeti/article/view/17121oai:proa.ua.pt:article/17121Eletrónica e Telecomunicações; Vol 4 No 7 (2007); 784-785Eletrónica e Telecomunicações; vol. 4 n.º 7 (2007); 784-7852182-97721645-0493reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttps://proa.ua.pt/index.php/revdeti/article/view/17121https://proa.ua.pt/index.php/revdeti/article/view/17121/12183https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessVarela, J.2022-09-26T11:00:10Zoai:proa.ua.pt:article/17121Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:08:07.301392Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv PET imaging in breast cancer diagnostics
title PET imaging in breast cancer diagnostics
spellingShingle PET imaging in breast cancer diagnostics
Varela, J.
title_short PET imaging in breast cancer diagnostics
title_full PET imaging in breast cancer diagnostics
title_fullStr PET imaging in breast cancer diagnostics
title_full_unstemmed PET imaging in breast cancer diagnostics
title_sort PET imaging in breast cancer diagnostics
author Varela, J.
author_facet Varela, J.
author_role author
dc.contributor.author.fl_str_mv Varela, J.
description A scanner for positron emission mammography is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes (APD) and readout by a fast low-noise electronic system. A dedicated digital trigger and data acquisition system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla.
publishDate 2007
dc.date.none.fl_str_mv 2007-01-01T00:00:00Z
dc.type.driver.fl_str_mv conference object
conference object
info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://proa.ua.pt/index.php/revdeti/article/view/17121
oai:proa.ua.pt:article/17121
url https://proa.ua.pt/index.php/revdeti/article/view/17121
identifier_str_mv oai:proa.ua.pt:article/17121
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://proa.ua.pt/index.php/revdeti/article/view/17121
https://proa.ua.pt/index.php/revdeti/article/view/17121/12183
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv UA Editora
publisher.none.fl_str_mv UA Editora
dc.source.none.fl_str_mv Eletrónica e Telecomunicações; Vol 4 No 7 (2007); 784-785
Eletrónica e Telecomunicações; vol. 4 n.º 7 (2007); 784-785
2182-9772
1645-0493
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130539050926080