Four suspensions for transtibial prosthetics: a case-study

Detalhes bibliográficos
Autor(a) principal: Matos, José Pedro
Data de Publicação: 2018
Outros Autores: Tomás, Maria Teresa
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.21/8148
Resumo: Objectives - The harmony between the residual limb and the prosthesis with an effective and comfortable suspension system allows the amputee to fully continue their daily living activities. With this study, the authors intended to measure gait efficiency and conclude whether the suspension systems tested differ in the various transtibial prostheses, based on the data provided by indirect calorimetry. Methodology - Functional performance that each suspension system allows will be approached by analyzing quantitative variables such as gait efficiency through indirect calorimetry using Lin-Chan protocols, which uses 5 different treadmill speeds. Results - Gait efficiency analysis of the four suspension systems (2 suction; 1 PIN; 1 VASS) showed that when comparing the four models, the most functional suspension system was the prosthesis with the active vacuum suspension system (VASS) with lower values for mlO2/kg/m and higher distance than other suspension systems. Conclusion - Differences in results of the tests carried out in the various suspension systems prove that indirect calorimetry is sensitive in the assessment of the identified variables and is a viable tool in the analysis of gait efficiency in amputees, proving that the VASS suspension system is what presents a greater efficiency in walking and so a higher functionality.
id RCAP_6a380b4b4bcd20f8ad5e311426a0174e
oai_identifier_str oai:repositorio.ipl.pt:10400.21/8148
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Four suspensions for transtibial prosthetics: a case-studyProstheticsSuspensionGait efficiencyFunctional performanceObjectives - The harmony between the residual limb and the prosthesis with an effective and comfortable suspension system allows the amputee to fully continue their daily living activities. With this study, the authors intended to measure gait efficiency and conclude whether the suspension systems tested differ in the various transtibial prostheses, based on the data provided by indirect calorimetry. Methodology - Functional performance that each suspension system allows will be approached by analyzing quantitative variables such as gait efficiency through indirect calorimetry using Lin-Chan protocols, which uses 5 different treadmill speeds. Results - Gait efficiency analysis of the four suspension systems (2 suction; 1 PIN; 1 VASS) showed that when comparing the four models, the most functional suspension system was the prosthesis with the active vacuum suspension system (VASS) with lower values for mlO2/kg/m and higher distance than other suspension systems. Conclusion - Differences in results of the tests carried out in the various suspension systems prove that indirect calorimetry is sensitive in the assessment of the identified variables and is a viable tool in the analysis of gait efficiency in amputees, proving that the VASS suspension system is what presents a greater efficiency in walking and so a higher functionality.IJMRPS Medical ConsultingRCIPLMatos, José PedroTomás, Maria Teresa2018-02-27T16:39:21Z2018-022018-02-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/8148engMatos JP, Tomás MT. Four suspensions for transtibial prosthetics: a case-study. Ind J Med Res Pharm Sci. 2018;5(2):11-8.10.5281/zenodo.1175225info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T09:55:09Zoai:repositorio.ipl.pt:10400.21/8148Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:16:57.710506Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Four suspensions for transtibial prosthetics: a case-study
title Four suspensions for transtibial prosthetics: a case-study
spellingShingle Four suspensions for transtibial prosthetics: a case-study
Matos, José Pedro
Prosthetics
Suspension
Gait efficiency
Functional performance
title_short Four suspensions for transtibial prosthetics: a case-study
title_full Four suspensions for transtibial prosthetics: a case-study
title_fullStr Four suspensions for transtibial prosthetics: a case-study
title_full_unstemmed Four suspensions for transtibial prosthetics: a case-study
title_sort Four suspensions for transtibial prosthetics: a case-study
author Matos, José Pedro
author_facet Matos, José Pedro
Tomás, Maria Teresa
author_role author
author2 Tomás, Maria Teresa
author2_role author
dc.contributor.none.fl_str_mv RCIPL
dc.contributor.author.fl_str_mv Matos, José Pedro
Tomás, Maria Teresa
dc.subject.por.fl_str_mv Prosthetics
Suspension
Gait efficiency
Functional performance
topic Prosthetics
Suspension
Gait efficiency
Functional performance
description Objectives - The harmony between the residual limb and the prosthesis with an effective and comfortable suspension system allows the amputee to fully continue their daily living activities. With this study, the authors intended to measure gait efficiency and conclude whether the suspension systems tested differ in the various transtibial prostheses, based on the data provided by indirect calorimetry. Methodology - Functional performance that each suspension system allows will be approached by analyzing quantitative variables such as gait efficiency through indirect calorimetry using Lin-Chan protocols, which uses 5 different treadmill speeds. Results - Gait efficiency analysis of the four suspension systems (2 suction; 1 PIN; 1 VASS) showed that when comparing the four models, the most functional suspension system was the prosthesis with the active vacuum suspension system (VASS) with lower values for mlO2/kg/m and higher distance than other suspension systems. Conclusion - Differences in results of the tests carried out in the various suspension systems prove that indirect calorimetry is sensitive in the assessment of the identified variables and is a viable tool in the analysis of gait efficiency in amputees, proving that the VASS suspension system is what presents a greater efficiency in walking and so a higher functionality.
publishDate 2018
dc.date.none.fl_str_mv 2018-02-27T16:39:21Z
2018-02
2018-02-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/8148
url http://hdl.handle.net/10400.21/8148
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Matos JP, Tomás MT. Four suspensions for transtibial prosthetics: a case-study. Ind J Med Res Pharm Sci. 2018;5(2):11-8.
10.5281/zenodo.1175225
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv IJMRPS Medical Consulting
publisher.none.fl_str_mv IJMRPS Medical Consulting
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133431513219072