Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de onda

Detalhes bibliográficos
Autor(a) principal: Marçal, Cecília Ferreira
Data de Publicação: 2021
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/1822/80630
Resumo: Dissertação de mestrado em Optometria Avançada
id RCAP_6d1406b6380269aec1d7d6fcac81298e
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/80630
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de ondaAccommodative response assessment for illumination of different wavelengthsAberração cromáticaAcomodação ocularIluminação coloridaIluminânciaTemperatura de corChromatic aberrationColor lightingColor temperatureEye accommodationLuminanceCiências Naturais::Ciências FísicasDissertação de mestrado em Optometria AvançadaNo mundo contemporâneo, somos cada vez mais dependentes da iluminação artificial para realizar todo o tipo de tarefas. Mas, no caso de não ser adequada, a iluminação pode levar ao aparecimento de fadiga e stress ocular. Este estudo pretendeu analisar a variação dos parâmetros acomodativos com a variação da cor da iluminação. O objetivo foi estimar a resposta acomodativa para iluminação sintonizada para diferentes comprimentos de onda. Foram avaliados 45 sujeitos com idades compreendidas entre os 18 e 35 anos, cujo 17 emetropes, 14 hipermetropes e 14 míopes. Foram excluídos indivíduos que padeciam correntemente de alguma patologia ocular ou sistémica, suscetível de alterar o valor refrativo normal, ou que tivessem sido sujeitos a qualquer intervenção cirúrgicas ou não cirúrgica (orto-k) no olho avaliado. A recolha de dados foi efetuada em duas etapas. A primeira consistiu num exame prévio constituído por exames preliminares, de visão binocular e acomodação. Na segunda fase foi determinada a AM e a FA sob uma iluminação de 3 comprimentos de ondas diferentes (115 lux) com picos em 455 nm (azul) e uma largura a meia altura do valor máximo de 26 nm, 510 nm (verde) e uma largura a meia altura do valor máximo de 34 nm e 625 nm (vermelho) e uma largura a meia altura do valor máximo de 21 nm. Os resultados indicam que a cor da iluminação influencia os resultados da AM, sendo esta maior com a luz azul, de seguida com a verde e por fim menor com a cor vermelha. Existem diferenças estatisticamente significativas na AM mediante as iluminações azul e verde entre o grupo de míopes e hipermetropes. Ainda em relação à AM existem diferenças nas três ametropias entre todos os cdo. Relativamente à FA não se detetou nenhuma influencia da cor. Para as três cores existiram diferenças estatisticamente significativas entre os míopes e os emetropes e entre os míopes e hipermetropes. No entanto, nos hipermetropes existiram diferenças entre a luz verde e a luz azul. Os resultados encontrados sugerem uma associação entre alguns parâmetros acomodativos e condições de iluminação específica. Iluminação imprópria ou com parâmetros desajustados podem causar uma variação nos parâmetros acomodativos e gerar sintomatologia.In today's contemporary world, we are increasingly dependent on artificial lighting to carry out all kinds of daily tasks. This study aimed to analyze the variation of accommodative parameters with thevariation of lighting color. The objective was to estimate the accommodative response for lighting set to different wavelengths. Forty-five subjects with ages ranging from 18 to 35 years old were subjected to the study, of which 17 were emmetropes, 14 hypermetropes and 14 myopes. Individuals who currently suffered from some systemic or ocular pathology, susceptible to changes to the normal refractive value, or whohad been subjected to any surgical or non-surgical intervention (ortho-k) in the evaluated eye, were excluded. Data collection was carried out in two stages. The first stage consisted of a preliminary exams, refractive exams, binocular vision and accommodation exams. In the second stage AM and FAwere determined under 115 lux illuminance with 3 different wavelengths with peaks at 455 nm for blue full width at half maximum at 26nm 510nm for green, full width at half maximum at 34nm and 625nm for red, full width at half maximum at 21nm. The results indicate that the lighting color influences the AM results, which is higher with blue light, then with green and finally lower with red. We also know that there are statistically significant differences in AM through the blue and green lighting between the hypermetropia and myopia groups. In relation to AM, there are differences between the three ametropias between all wavelengths. Regarding AF, no influence of the light color was detected. For the three colors there were statistically significant differences between the emmetropia and myopia groups and the hypermetropia and myopia groups. However, in hypermetropes there were differences observed between green andblue lighting. The results found suggest a relation between some accommodative parameters and specific lighting conditions. improper lighting or inadequate parameters can cause a variation in the accommodative parameters and generate symptoms.Franco, SandraLinhares, João M. M.Universidade do MinhoMarçal, Cecília Ferreira2021-12-302021-12-30T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttps://hdl.handle.net/1822/80630por202990672info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-23T01:31:55Zoai:repositorium.sdum.uminho.pt:1822/80630Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:23:05.790466Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de onda
Accommodative response assessment for illumination of different wavelengths
title Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de onda
spellingShingle Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de onda
Marçal, Cecília Ferreira
Aberração cromática
Acomodação ocular
Iluminação colorida
Iluminância
Temperatura de cor
Chromatic aberration
Color lighting
Color temperature
Eye accommodation
Luminance
Ciências Naturais::Ciências Físicas
title_short Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de onda
title_full Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de onda
title_fullStr Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de onda
title_full_unstemmed Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de onda
title_sort Avaliação da resposta acomodativa para iluminação de diferentes comprimentos de onda
author Marçal, Cecília Ferreira
author_facet Marçal, Cecília Ferreira
author_role author
dc.contributor.none.fl_str_mv Franco, Sandra
Linhares, João M. M.
Universidade do Minho
dc.contributor.author.fl_str_mv Marçal, Cecília Ferreira
dc.subject.por.fl_str_mv Aberração cromática
Acomodação ocular
Iluminação colorida
Iluminância
Temperatura de cor
Chromatic aberration
Color lighting
Color temperature
Eye accommodation
Luminance
Ciências Naturais::Ciências Físicas
topic Aberração cromática
Acomodação ocular
Iluminação colorida
Iluminância
Temperatura de cor
Chromatic aberration
Color lighting
Color temperature
Eye accommodation
Luminance
Ciências Naturais::Ciências Físicas
description Dissertação de mestrado em Optometria Avançada
publishDate 2021
dc.date.none.fl_str_mv 2021-12-30
2021-12-30T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/80630
url https://hdl.handle.net/1822/80630
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv 202990672
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132704490389504