A influência de iluminação colorida nos parâmetros acomodativos oculares
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/65320 |
Resumo: | Dissertação de mestrado em Optometria Avançada |
id |
RCAP_a8dd281c6ffe387f008390a70599568b |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/65320 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
A influência de iluminação colorida nos parâmetros acomodativos ocularesThe influence of the coloured lighting on ocular accommodationAcomodação ocularIluminação coloridaIluminânciaTemperatura de cor correlacionadaColored lightingIlluminanceCorrelated color temperatureOcular accommodationCiências Naturais::Ciências FísicasDissertação de mestrado em Optometria AvançadaOs sistemas de iluminação que utilizamos nas nossas tarefas diárias são um fator importante para o desempenho visual. Estes sistemas devem ser adequados às necessidades visuais exigidas por este tipo de tarefa. O objetivo deste estudo foi analisar a influência de determinados parâmetros da iluminação, nomeadamente a iluminância, cor e temperatura de cor, nos parâmetros acomodativos oculares. Foram avaliados 26 sujeitos com idades compreendidas entre os 18 e os 35 anos, sem problemas acomodativos e com visão das cores normal. Primeiro, determinou-se o erro refrativo, os parâmetros acomodativos e de visão binocular de todos os participantes. De seguida, os parâmetros acomodativos foram determinados em diferentes condições de iluminação. Foi medida a amplitude de acomodação e flexibilidade acomodativa em diferentes níveis de iluminância (30lx, 150lx e 400lx), iluminação colorida (verde e vermelho) e em iluminações com diferentes temperaturas de cor correlacionada (2500 K e 4500 K) que procuravam mimetizar condições de luz do dia para temperaturas de cor correspondentes. Para a realização das medidas sob diferentes condições foi utilizada a lâmpada Ledigma (Ledigma Ltd, Vilnius, Lithuania). Na variação da iluminância, verificou-se um aumento estatisticamente significativo na amplitude de acomodação dos 30lx para os 150lx (p<0,001; t-student test). A amplitude de acomodação medida com a iluminância de 400lx também apresentou um aumento estatisticamente significativo (p<0,001; t-student test) quando comparado à obtida com iluminância de 30lx. Contudo a amplitude de acomodação medida com a iluminância de 150lx não apresentou diferenças estatisticamente significativas quando compara à obtida com a iluminância de 400lx (p>0,05). Em termos de flexibilidade acomodativa, esta apresentou um aumento estatisticamente significativo dos 30lx para os 400lx (p<0,001; t-student test). Relativamente à iluminação colorida, os valores de amplitude de acomodação apresentaram uma diminuição estatisticamente significativa com a iluminação vermelha, quando confrontados com os obtidos com a luz branca (p=0,016; t-student test). A amplitude de acomodação medida sob a iluminação vermelha, apresentou uma diminuição estatisticamente significativa quando comparada com a obtida com a cor verde (p<0,001; t-student test). No entanto, a amplitude de acomodação medida com a luz de cor verde não apresentou diferenças estatisticamente significativas quando comparada à obtida com a luz branca (p>0,05). Em termos de flexibilidade acomodativa, não foram encontrados valores estatisticamente significativos (p>0,05; t-student test) para as condições testadas. O mesmo aconteceu com a temperatura de cor, em que não foram encontrados valores estatisticamente significativos entre os 2500 K e os 4500 K (p>0,05; t-student test). Os resultados encontrados sugerem uma associação entre alguns parâmetros acomodativos e condições de iluminação específica. Iluminação imprópria ou com parâmetros desajustados podem causar uma variação nos parâmetros acomodativos e gerar sintomatologia.The lighting systems that is used in our daily tasks are an important factor in our vision performance. These systems must be suitable to the visual needs required by these types of tasks. The aim of this work was to evaluate the influence of specific lighting parameters, in particular illuminance, color and color temperature, on ocular accommodative parameters. Twenty-six subjects were accessed with ages between 18 and 35 years, without accommodative disorders and with normal vision color. First, refractive error, accommodative parameters and binocular vision of all the participants were measured. Then, the accommodative parameters were determined in different illumination conditions. The amplitude of accommodation and accommodative facility were measured under different illuminance levels (30lx, 150lx and 400lx), colored lighting (green and red) and under different correlated color temperature (2500K and 4500K) that trying to imitate daylight conditions for corresponding color temperatures. Measurements under the different conditions were done using a Ledigma luminary (Ledigma Ltd, Vilnius, Lithuania). Considering the illuminance, there was a statistically significant increase in the amplitude of accommodation from 30lx to 150lx (p<0.001; t-student test). The amplitude of accommodation measured with 400lx illuminance also showed a statistically significant increase (p<0.001; tstudent test) when compared to that obtained with 30lx illuminance. However, the amplitude of accommodation measured with the illuminance of 150lx didn’t present statistically significant differences when compared to that obtained with the illuminance of 400lx (p>0.05). In terms of accommodative flexibility, this increased significantly from 30lx to 400lx (p<0.001; t-student test). Regarding the colored lighting, the accommodation amplitude values presented significantly lower values with red lighting when compared with those obtained with white light (p=0.016; t-student test). Accommodation amplitude measured under red illumination, showed a statistically significant decrease when compared to that obtained with the green color (p<0.001; tstudent test). However, the amplitude of accommodation measured with green light did not present statistically significant differences when compared to that obtained with white light (p>0.05). In terms of accommodative flexibility, no statistically significant values were found for the conditions tested (p>0.05; t-student test). The same happened to the color temperature, where no statistically significant values were found between 2500K and 4500K (p>0.05; t-student test). Results seemed to show that particular light conditions influenced the amplitude of accommodation and accommodative facility. Improper lighting or inadequate parameters can cause a variation in accommodative parameters and cause symptomatology.Este trabalho foi financiado por Fundos Nacionais através da FCT – Fundação para a Ciência e a Tecnologia no âmbito do projeto PTDC/FIS-OTI/31486/2017Franco, SandraLinhares, João M. M.Universidade do MinhoMoreira, Ana Raquel de Pinho20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/1822/65320por202471900info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:41:23Zoai:repositorium.sdum.uminho.pt:1822/65320Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:38:21.630543Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
A influência de iluminação colorida nos parâmetros acomodativos oculares The influence of the coloured lighting on ocular accommodation |
title |
A influência de iluminação colorida nos parâmetros acomodativos oculares |
spellingShingle |
A influência de iluminação colorida nos parâmetros acomodativos oculares Moreira, Ana Raquel de Pinho Acomodação ocular Iluminação colorida Iluminância Temperatura de cor correlacionada Colored lighting Illuminance Correlated color temperature Ocular accommodation Ciências Naturais::Ciências Físicas |
title_short |
A influência de iluminação colorida nos parâmetros acomodativos oculares |
title_full |
A influência de iluminação colorida nos parâmetros acomodativos oculares |
title_fullStr |
A influência de iluminação colorida nos parâmetros acomodativos oculares |
title_full_unstemmed |
A influência de iluminação colorida nos parâmetros acomodativos oculares |
title_sort |
A influência de iluminação colorida nos parâmetros acomodativos oculares |
author |
Moreira, Ana Raquel de Pinho |
author_facet |
Moreira, Ana Raquel de Pinho |
author_role |
author |
dc.contributor.none.fl_str_mv |
Franco, Sandra Linhares, João M. M. Universidade do Minho |
dc.contributor.author.fl_str_mv |
Moreira, Ana Raquel de Pinho |
dc.subject.por.fl_str_mv |
Acomodação ocular Iluminação colorida Iluminância Temperatura de cor correlacionada Colored lighting Illuminance Correlated color temperature Ocular accommodation Ciências Naturais::Ciências Físicas |
topic |
Acomodação ocular Iluminação colorida Iluminância Temperatura de cor correlacionada Colored lighting Illuminance Correlated color temperature Ocular accommodation Ciências Naturais::Ciências Físicas |
description |
Dissertação de mestrado em Optometria Avançada |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 2019-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/65320 |
url |
http://hdl.handle.net/1822/65320 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
202471900 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132920601903104 |