CTC : influência da experiência do leitor e do CAD no desempenho diagnóstico

Detalhes bibliográficos
Autor(a) principal: Almeida, João Pedro Lemos Ferreira de
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/84783
Resumo: Trabalho final de mestrado integrado em Medicina área científica de Imagiologia, apresentado à Faculdade de Medicina da Universidade de Coimbra
id RCAP_6f920f6817ccb03cefea23979d66f383
oai_identifier_str oai:estudogeral.uc.pt:10316/84783
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling CTC : influência da experiência do leitor e do CAD no desempenho diagnósticoTumografia por raios X computorizadaNeoplasias colorrectaisTécnicas e procedimentos diagnósticosDomínio/Área Científica::Ciências MédicasTrabalho final de mestrado integrado em Medicina área científica de Imagiologia, apresentado à Faculdade de Medicina da Universidade de CoimbraObjectivos:Neste trabalho pretendeu avaliar-se a influência da experiência no desempenho diagnóstico dos leitores e nos tempos de leitura na colonografia por tomografia computadorizada (CTC), além de determinar o efeito da detecção auxiliada por computador (computer-aideddetection - CAD) em leitores com diferentes níveis de experiência. Materiais e Métodos: Três leitores de diferentes níveis de experiência (leitor 1: sem qualquer experiência; leitor 2: experiência de <100 casos; leitor 3: experiência de>300casos) analisaram, numa primeira fase, uma base de dados de 30 CTC (28 pólipos ≥6mm, quatro carcinomas e três casos negativos) sem acesso ao CAD. Numa segunda fase reavaliaram a base de dados com acesso ao CAD num paradigma de leitura simultânea (concurrentreadCAD). Foram calculadas e comparadas as sensibilidades, especificidades, curvas ROC e tempos de leitura dos três leitores para ambas as fases. Resultados: As sensibilidades por pólipo sem CAD foram de 93,75%, 96,875% e 100% para os leitores 1, 2 e 3 respectivamente, e com CAD de 100%, 96,875% e 100% respectivamente. Não houve diferenças estatísticas nos resultados. As sensibilidades e especificidades por segmento (tendo o cólon sido divido em ascendente, transverso, descendente, sigmóide e recto), sem CAD, foram respectivamente de 93,10% e 99,17% para o leitor 1, 96,55% e 100,00% para o leitor 2 e 100% e 100% para o leitor 3. Com CAD foram de 100% e 97,52% para o leitor 1 e mantiveram-se inalteradas para os restantes leitores. Não houve diferenças estatisticamente significativas entre os resultados. Os tempos médios de leitura sem CAD foram de 19,00 min, 11,93min e 15,07min para os leitores 1, 2 e 3 respectivamente. E com CAD de 12,87min, 11,37min e 8,27min respectivamente. Houve redução significativa nos tempos médios de leitura dos leitores 1 e 3. Conclusão: Este estudo demonstra uma tendênciapara que o desempenho diagnóstico dos leitores seja dependente da experiência nas leituras sem CAD e que o CAD possa melhorar a sensibilidade de leitores menos experientes, no entanto, não foi obtida significância estatística. Além disso, um paradigma de concurrentread CAD pode uniformizar e reduzir significativamente os tempos de leitura.Objectives: The purpose of this study was to assess the influence of experience on the performance of readers and reading time in CT colonography (CTC) and also to determine the effect of computer-aided detection (CAD) on readers with different levels of experience. Materials e Methods: Three readers of different levels of experience (reader 1: no experience; reader 2: experience of <100 cases; reader 3: experience of >250 cases) reviewed 30 CTC patient data-sets (28 polyps ≥6mm, four carcinomas and three negative patients) without access to CAD. On a second phase of the study a second reading was performed with CAD on a concurrent read CAD paradigm. Sensitivities, specificities, ROC curves and reading times were calculated and compared for the three readers on both phases. Results: Per polyp sensitivities without CAD were 93,75%, 96,875% and 100% for readers 1, 2 and 3 respectively, and 100%, 96,875% and 100% respectively with CAD. There were no statistical differences between these results. Sensitivities and specificities per segment (being the colon divided in ascending, transverse, descending, sigmoid and rectum), without CAD, were respectively 93,10% and 99,17% for reader 1, 96,55% and 100,00% for reader 2 and 100% and 100% for reader 3. With CAD they changed to 100% and 97,52% for reader 1 and kept unchanged for the remaining readers. Again there were no statistical differences between these results. The mean reading times without CAD were 19,00 min, 11,93min e 15,07min for readers 1, 2 and 3 respectively and 12,87min, 11,37min e 8,27min respectively with CAD. There was a statistical significant reduction the in mean reading times of readers 1 and 3. Conclusion: This study indicates that reader performance tends to be dependent on experience in the readings without CAD and that CAD may increase the sensitivity of inexperienced readers although statistical significance was not archived. Furthermore, a concurrent read CAD paradigm might even out and significantly reduce reading times2011-04info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/84783http://hdl.handle.net/10316/84783porAlmeida, João Pedro Lemos Ferreira deinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-01-20T17:48:43Zoai:estudogeral.uc.pt:10316/84783Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:06:18.385168Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv CTC : influência da experiência do leitor e do CAD no desempenho diagnóstico
title CTC : influência da experiência do leitor e do CAD no desempenho diagnóstico
spellingShingle CTC : influência da experiência do leitor e do CAD no desempenho diagnóstico
Almeida, João Pedro Lemos Ferreira de
Tumografia por raios X computorizada
Neoplasias colorrectais
Técnicas e procedimentos diagnósticos
Domínio/Área Científica::Ciências Médicas
title_short CTC : influência da experiência do leitor e do CAD no desempenho diagnóstico
title_full CTC : influência da experiência do leitor e do CAD no desempenho diagnóstico
title_fullStr CTC : influência da experiência do leitor e do CAD no desempenho diagnóstico
title_full_unstemmed CTC : influência da experiência do leitor e do CAD no desempenho diagnóstico
title_sort CTC : influência da experiência do leitor e do CAD no desempenho diagnóstico
author Almeida, João Pedro Lemos Ferreira de
author_facet Almeida, João Pedro Lemos Ferreira de
author_role author
dc.contributor.author.fl_str_mv Almeida, João Pedro Lemos Ferreira de
dc.subject.por.fl_str_mv Tumografia por raios X computorizada
Neoplasias colorrectais
Técnicas e procedimentos diagnósticos
Domínio/Área Científica::Ciências Médicas
topic Tumografia por raios X computorizada
Neoplasias colorrectais
Técnicas e procedimentos diagnósticos
Domínio/Área Científica::Ciências Médicas
description Trabalho final de mestrado integrado em Medicina área científica de Imagiologia, apresentado à Faculdade de Medicina da Universidade de Coimbra
publishDate 2011
dc.date.none.fl_str_mv 2011-04
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/84783
http://hdl.handle.net/10316/84783
url http://hdl.handle.net/10316/84783
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133953698824192