Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for Use
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , |
Tipo de documento: | Relatório |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-706X2020000200008 |
Resumo: | Introduction: We present the case of a superficial femoral artery ruptured aneurysm treated with an endoprothesis outside the Instructions for Use. Case report: 83 years old patient with sequential rupture of both superficial femoral arteries aneurysms. In the right limb the patient was submitted to conventional bypass surgery that resulted in an extended recovery period. An endovascular approach was the choice to treat the left ruptured superficial femoral artery aneurysm. The patient was submitted to aneurysm exclusion with two Endurant"II Medtronic® endoprothesis. At two-year follow-up the patient is asymptomatic and the aneurysm remains excluded with no endoleaks. Conclusions: Despite outside Instructions for Use, the use of an endoprothesis to treat SFA ruptured aneurysm presented as limb salvage procedure with excellent technical success and medium-term results. |
id |
RCAP_706614a3151dd014ecc880eb5b185e9d |
---|---|
oai_identifier_str |
oai:scielo:S1646-706X2020000200008 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for UseFemoral aneurysmRupture; EndoprothesisIntroduction: We present the case of a superficial femoral artery ruptured aneurysm treated with an endoprothesis outside the Instructions for Use. Case report: 83 years old patient with sequential rupture of both superficial femoral arteries aneurysms. In the right limb the patient was submitted to conventional bypass surgery that resulted in an extended recovery period. An endovascular approach was the choice to treat the left ruptured superficial femoral artery aneurysm. The patient was submitted to aneurysm exclusion with two Endurant"II Medtronic® endoprothesis. At two-year follow-up the patient is asymptomatic and the aneurysm remains excluded with no endoleaks. Conclusions: Despite outside Instructions for Use, the use of an endoprothesis to treat SFA ruptured aneurysm presented as limb salvage procedure with excellent technical success and medium-term results.Sociedade Portuguesa de Angiologia e Cirurgia Vascular2020-06-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/reporttext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-706X2020000200008Angiologia e Cirurgia Vascular v.16 n.2 2020reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-706X2020000200008Correia,MafaldaLima,PedroAntunes,LuísAlegrio,JoãoFonseca,Manuelinfo:eu-repo/semantics/openAccess2024-02-06T17:22:58Zoai:scielo:S1646-706X2020000200008Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:29:26.355162Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for Use |
title |
Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for Use |
spellingShingle |
Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for Use Correia,Mafalda Femoral aneurysm Rupture; Endoprothesis |
title_short |
Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for Use |
title_full |
Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for Use |
title_fullStr |
Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for Use |
title_full_unstemmed |
Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for Use |
title_sort |
Exclusion of a large ruptured superficial femoral artery aneurysm with two endoprothesis outside the Instructions for Use |
author |
Correia,Mafalda |
author_facet |
Correia,Mafalda Lima,Pedro Antunes,Luís Alegrio,João Fonseca,Manuel |
author_role |
author |
author2 |
Lima,Pedro Antunes,Luís Alegrio,João Fonseca,Manuel |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Correia,Mafalda Lima,Pedro Antunes,Luís Alegrio,João Fonseca,Manuel |
dc.subject.por.fl_str_mv |
Femoral aneurysm Rupture; Endoprothesis |
topic |
Femoral aneurysm Rupture; Endoprothesis |
description |
Introduction: We present the case of a superficial femoral artery ruptured aneurysm treated with an endoprothesis outside the Instructions for Use. Case report: 83 years old patient with sequential rupture of both superficial femoral arteries aneurysms. In the right limb the patient was submitted to conventional bypass surgery that resulted in an extended recovery period. An endovascular approach was the choice to treat the left ruptured superficial femoral artery aneurysm. The patient was submitted to aneurysm exclusion with two Endurant"II Medtronic® endoprothesis. At two-year follow-up the patient is asymptomatic and the aneurysm remains excluded with no endoleaks. Conclusions: Despite outside Instructions for Use, the use of an endoprothesis to treat SFA ruptured aneurysm presented as limb salvage procedure with excellent technical success and medium-term results. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-06-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/report |
format |
report |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-706X2020000200008 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-706X2020000200008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-706X2020000200008 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Angiologia e Cirurgia Vascular |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Angiologia e Cirurgia Vascular |
dc.source.none.fl_str_mv |
Angiologia e Cirurgia Vascular v.16 n.2 2020 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137361672536064 |