EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”

Detalhes bibliográficos
Autor(a) principal: Correia, Mafalda
Data de Publicação: 2020
Outros Autores: Lima, Pedro, Antunes, Luís, Alegrio, João, Fonseca, Manuel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://doi.org/10.48750/acv.301
Resumo: Introduction: We present the case of a superficial femoral artery ruptured aneurysm treated with an endoprothesis outside the “Instructions for Use”. Case report: 83 years old patient with sequential rupture of both superficial femoral arteries aneurysms. In the right limb the patient was submitted to conventional bypass surgery that resulted in an extended recovery period. An endovascular approach was the choice to treat the left ruptured superficial femoral artery aneurysm. The patient was submitted to aneurysm exclusion with two Endurant™II Medtronic® endoprothesis. At two-year follow-up the patient is asymptomatic and the aneurysm remains excluded with no endoleaks. Conclusions: Despite outside “Instructions for Use”, the use of an endoprothesis to treat SFA ruptured aneurysm presented as limb salvage procedure with excellent technical success and medium-term results.
id RCAP_c6f4027dd66d0fe42ea63d6b59e97266
oai_identifier_str oai:ojs.acvjournal.com:article/301
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”EXCLUSÃO DE UM VOLUMOSO ANEURISMA DA ARTÉRIA FEMORAL SUPERFICIAL ROTO COM DUAS ENDOPRÓTESES FORA DAS “INSTRUCTIONS FOR USE”Femoral aneurysmRuptureEndoprothesisAneurisma femoralRoturaEndopróteseIntroduction: We present the case of a superficial femoral artery ruptured aneurysm treated with an endoprothesis outside the “Instructions for Use”. Case report: 83 years old patient with sequential rupture of both superficial femoral arteries aneurysms. In the right limb the patient was submitted to conventional bypass surgery that resulted in an extended recovery period. An endovascular approach was the choice to treat the left ruptured superficial femoral artery aneurysm. The patient was submitted to aneurysm exclusion with two Endurant™II Medtronic® endoprothesis. At two-year follow-up the patient is asymptomatic and the aneurysm remains excluded with no endoleaks. Conclusions: Despite outside “Instructions for Use”, the use of an endoprothesis to treat SFA ruptured aneurysm presented as limb salvage procedure with excellent technical success and medium-term results.Introdução: Apresenta-se um caso de rotura de aneurisma da artéria femoral superficial tratado com uma endoprótese fora das “Instructions for Use”. Caso clínico: Doente de 83 anos com rotura sequencial de aneurismas de ambas as artérias femorais superficiais. À direita, o paciente foi submetido a cirurgia de bypass que resultou num período de recuperação prolongado, pelo que à esquerda se optou por uma abordagem endovascular. Procedeu-se à exclusão do aneurisma com duas endopróteses Endurant™II Medtronic®. Aos dois anos de follow-up o paciente encontra-se assintomático e sem endoleaks. Conclusão: Apesar de fora das “Instructions for Use”, o uso de endopróteses na exclusão de um aneurisma da artéria femoral superficial revelou-se como um procedimento limb-salvage com um sucesso técnico e resultados a médio prazo excelentes.Sociedade Portuguesa de Angiologia e Cirurgia Vascular2020-08-05T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.48750/acv.301oai:ojs.acvjournal.com:article/301Angiologia e Cirurgia Vascular; Vol. 16 No. 2 (2020): June; 106-109Angiologia e Cirurgia Vascular; Vol. 16 N.º 2 (2020): Junho; 106-1092183-00961646-706Xreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://acvjournal.com/index.php/acv/article/view/301https://doi.org/10.48750/acv.301http://acvjournal.com/index.php/acv/article/view/301/185Copyright (c) 2020 Angiologia e Cirurgia Vascularinfo:eu-repo/semantics/openAccessCorreia, MafaldaLima, PedroAntunes, LuísAlegrio, JoãoFonseca, Manuel2022-05-23T15:10:09Zoai:ojs.acvjournal.com:article/301Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T14:57:40.123083Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”
EXCLUSÃO DE UM VOLUMOSO ANEURISMA DA ARTÉRIA FEMORAL SUPERFICIAL ROTO COM DUAS ENDOPRÓTESES FORA DAS “INSTRUCTIONS FOR USE”
title EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”
spellingShingle EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”
Correia, Mafalda
Femoral aneurysm
Rupture
Endoprothesis
Aneurisma femoral
Rotura
Endoprótese
title_short EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”
title_full EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”
title_fullStr EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”
title_full_unstemmed EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”
title_sort EXCLUSION OF A LARGE RUPTURED SUPERFICIAL FEMORAL ARTERY ANEURYSM WITH TWO ENDOPROTHESIS OUTSIDE THE “INSTRUCTIONS FOR USE”
author Correia, Mafalda
author_facet Correia, Mafalda
Lima, Pedro
Antunes, Luís
Alegrio, João
Fonseca, Manuel
author_role author
author2 Lima, Pedro
Antunes, Luís
Alegrio, João
Fonseca, Manuel
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Correia, Mafalda
Lima, Pedro
Antunes, Luís
Alegrio, João
Fonseca, Manuel
dc.subject.por.fl_str_mv Femoral aneurysm
Rupture
Endoprothesis
Aneurisma femoral
Rotura
Endoprótese
topic Femoral aneurysm
Rupture
Endoprothesis
Aneurisma femoral
Rotura
Endoprótese
description Introduction: We present the case of a superficial femoral artery ruptured aneurysm treated with an endoprothesis outside the “Instructions for Use”. Case report: 83 years old patient with sequential rupture of both superficial femoral arteries aneurysms. In the right limb the patient was submitted to conventional bypass surgery that resulted in an extended recovery period. An endovascular approach was the choice to treat the left ruptured superficial femoral artery aneurysm. The patient was submitted to aneurysm exclusion with two Endurant™II Medtronic® endoprothesis. At two-year follow-up the patient is asymptomatic and the aneurysm remains excluded with no endoleaks. Conclusions: Despite outside “Instructions for Use”, the use of an endoprothesis to treat SFA ruptured aneurysm presented as limb salvage procedure with excellent technical success and medium-term results.
publishDate 2020
dc.date.none.fl_str_mv 2020-08-05T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.48750/acv.301
oai:ojs.acvjournal.com:article/301
url https://doi.org/10.48750/acv.301
identifier_str_mv oai:ojs.acvjournal.com:article/301
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://acvjournal.com/index.php/acv/article/view/301
https://doi.org/10.48750/acv.301
http://acvjournal.com/index.php/acv/article/view/301/185
dc.rights.driver.fl_str_mv Copyright (c) 2020 Angiologia e Cirurgia Vascular
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2020 Angiologia e Cirurgia Vascular
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Angiologia e Cirurgia Vascular
publisher.none.fl_str_mv Sociedade Portuguesa de Angiologia e Cirurgia Vascular
dc.source.none.fl_str_mv Angiologia e Cirurgia Vascular; Vol. 16 No. 2 (2020): June; 106-109
Angiologia e Cirurgia Vascular; Vol. 16 N.º 2 (2020): Junho; 106-109
2183-0096
1646-706X
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799129849791512576