Development of a New Amperometric Biosensor for Lactose Determination
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042003000200005 |
Resumo: | A new amperometric biosensor for lactose determinaion in raw milk was developed through the simultaneous immobilization of β-galactosidase and galactose oxidase on a derivatised polyethersulphone membrane. β-galactosidase catalyses the hydrolysis of lactose into galactose and glucose and galactose oxidase catalyses the oxidation of galactose into galactonic acid and H2O2. The membranes with the two immobilized enzymes were then used in an amperometric sensor, by oxidation of the H2O2 formed, at a Pt electrode of an Universal Sensors electrode base system. The sensitivity and the reproducibility of the biosensor thus formed were found to be 6.81 and 0.72 nA.M-1, respectively. Biosensors were found to be stable for 20 days. |
id |
RCAP_75a23e5bee2756c2767596cecd7be784 |
---|---|
oai_identifier_str |
oai:scielo:S0872-19042003000200005 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Development of a New Amperometric Biosensor for Lactose Determinationbiosensorlactoseamperometricstabilization<FONT FACE=Symbol>b</font>-galactosidasegalactose oxidaseA new amperometric biosensor for lactose determinaion in raw milk was developed through the simultaneous immobilization of β-galactosidase and galactose oxidase on a derivatised polyethersulphone membrane. β-galactosidase catalyses the hydrolysis of lactose into galactose and glucose and galactose oxidase catalyses the oxidation of galactose into galactonic acid and H2O2. The membranes with the two immobilized enzymes were then used in an amperometric sensor, by oxidation of the H2O2 formed, at a Pt electrode of an Universal Sensors electrode base system. The sensitivity and the reproducibility of the biosensor thus formed were found to be 6.81 and 0.72 nA.M-1, respectively. Biosensors were found to be stable for 20 days.Sociedade Portuguesa de Electroquímica2003-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042003000200005Portugaliae Electrochimica Acta v.21 n.2 2003reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042003000200005Lourenço,R.J.M.Serralheiro,M.L.M.Rebelo,M.J.F.info:eu-repo/semantics/openAccess2024-02-06T17:06:41Zoai:scielo:S0872-19042003000200005Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:19:56.072162Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Development of a New Amperometric Biosensor for Lactose Determination |
title |
Development of a New Amperometric Biosensor for Lactose Determination |
spellingShingle |
Development of a New Amperometric Biosensor for Lactose Determination Lourenço,R.J.M. biosensor lactose amperometric stabilization <FONT FACE=Symbol>b</font>-galactosidase galactose oxidase |
title_short |
Development of a New Amperometric Biosensor for Lactose Determination |
title_full |
Development of a New Amperometric Biosensor for Lactose Determination |
title_fullStr |
Development of a New Amperometric Biosensor for Lactose Determination |
title_full_unstemmed |
Development of a New Amperometric Biosensor for Lactose Determination |
title_sort |
Development of a New Amperometric Biosensor for Lactose Determination |
author |
Lourenço,R.J.M. |
author_facet |
Lourenço,R.J.M. Serralheiro,M.L.M. Rebelo,M.J.F. |
author_role |
author |
author2 |
Serralheiro,M.L.M. Rebelo,M.J.F. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Lourenço,R.J.M. Serralheiro,M.L.M. Rebelo,M.J.F. |
dc.subject.por.fl_str_mv |
biosensor lactose amperometric stabilization <FONT FACE=Symbol>b</font>-galactosidase galactose oxidase |
topic |
biosensor lactose amperometric stabilization <FONT FACE=Symbol>b</font>-galactosidase galactose oxidase |
description |
A new amperometric biosensor for lactose determinaion in raw milk was developed through the simultaneous immobilization of β-galactosidase and galactose oxidase on a derivatised polyethersulphone membrane. β-galactosidase catalyses the hydrolysis of lactose into galactose and glucose and galactose oxidase catalyses the oxidation of galactose into galactonic acid and H2O2. The membranes with the two immobilized enzymes were then used in an amperometric sensor, by oxidation of the H2O2 formed, at a Pt electrode of an Universal Sensors electrode base system. The sensitivity and the reproducibility of the biosensor thus formed were found to be 6.81 and 0.72 nA.M-1, respectively. Biosensors were found to be stable for 20 days. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042003000200005 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042003000200005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042003000200005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
dc.source.none.fl_str_mv |
Portugaliae Electrochimica Acta v.21 n.2 2003 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1817550060633718784 |