Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint

Detalhes bibliográficos
Autor(a) principal: Cruz, Ana
Data de Publicação: 2020
Outros Autores: Cunha, Beatriz, Pereira, Ana, Rodrigues, Maria, Seabra, Eurico Augusto, Silva, Luís, Colim, Ana, Viana, Rui
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.19/6629
Resumo: Introduction: Currently, there are several types of devices and techniques for the rehabilitation of the tibiotarsal joint. However, complete and effective rehabilitation still falls short of expectations, since the existing devices are not adaptable to the level of torque and the number of repetitions and sessions to be performed, as these depend on each patient and on the stage at which he is finds. Objetives: To improve a mechatronic device for the rehabilitation of the tibiotarsal joint, the Therapheet. Methods: This study presents a review of the tibiotarsal joint rehabilitation protocols, as well as the classification of devices used for this purpose. Thus, the purpose is to improve the Therapheet, developed at the Department of Mechanical Engineering of the University of Minho, obtaining a viable, functional and safe rehabilitation device, standing out from the rest on the market, since it allows the execution of the six rehabilitation exercises. Results: It was obtained a prototype of equipment for rehabilitation of the tibiotarsal joint was obtained, proposing changes for improvement according to the specificities and requirements for such a device, having been subjected to a series of preliminary tests to verify its functionality, performance and suitability. The equipment proved to be functional, in terms of executing the ankle rehabilitation movements, however, it still manifests some flaws in terms of the user's stability, sudden movements, and above all dysfunctions arising from excess mass that make up its structure and limitations pneumatic technology adopted. Conclusions: The control of the amplitude of the characteristic angles of the movements of the foot is still done manually, so it would be significant to implement an automated system that would allow the control of the range of amplitude, according to the patient's rehabilitation phase. One option would be the implementation of a new technology, such as the insertion of servomotors.
id RCAP_75fa6b84d07f2184535f1d513543a73a
oai_identifier_str oai:repositorio.ipv.pt:10400.19/6629
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Jointtibiotarsal jointautomationdevicerehabilitationtherapheetIntroduction: Currently, there are several types of devices and techniques for the rehabilitation of the tibiotarsal joint. However, complete and effective rehabilitation still falls short of expectations, since the existing devices are not adaptable to the level of torque and the number of repetitions and sessions to be performed, as these depend on each patient and on the stage at which he is finds. Objetives: To improve a mechatronic device for the rehabilitation of the tibiotarsal joint, the Therapheet. Methods: This study presents a review of the tibiotarsal joint rehabilitation protocols, as well as the classification of devices used for this purpose. Thus, the purpose is to improve the Therapheet, developed at the Department of Mechanical Engineering of the University of Minho, obtaining a viable, functional and safe rehabilitation device, standing out from the rest on the market, since it allows the execution of the six rehabilitation exercises. Results: It was obtained a prototype of equipment for rehabilitation of the tibiotarsal joint was obtained, proposing changes for improvement according to the specificities and requirements for such a device, having been subjected to a series of preliminary tests to verify its functionality, performance and suitability. The equipment proved to be functional, in terms of executing the ankle rehabilitation movements, however, it still manifests some flaws in terms of the user's stability, sudden movements, and above all dysfunctions arising from excess mass that make up its structure and limitations pneumatic technology adopted. Conclusions: The control of the amplitude of the characteristic angles of the movements of the foot is still done manually, so it would be significant to implement an automated system that would allow the control of the range of amplitude, according to the patient's rehabilitation phase. One option would be the implementation of a new technology, such as the insertion of servomotors.Instituto Politécnico de ViseuRepositório Científico do Instituto Politécnico de ViseuCruz, AnaCunha, BeatrizPereira, AnaRodrigues, MariaSeabra, Eurico AugustoSilva, LuísColim, AnaViana, Rui2021-02-24T17:10:32Z20202021-02-24T16:11:15Z2020-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.19/6629engCruz, A., Cunha, B., Pereira, A., Rodrigues, M., Seabra, E. A., Silva, L., Colim, A., & Viana, R. (2020). Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint. Millenium, 2(12), 13-23. DOI: 10.29352/mill0212.01.0032410.29352/mill0212.01.00324info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-01-16T15:28:51Zoai:repositorio.ipv.pt:10400.19/6629Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:44:27.736761Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint
title Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint
spellingShingle Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint
Cruz, Ana
tibiotarsal joint
automation
device
rehabilitation
therapheet
title_short Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint
title_full Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint
title_fullStr Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint
title_full_unstemmed Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint
title_sort Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint
author Cruz, Ana
author_facet Cruz, Ana
Cunha, Beatriz
Pereira, Ana
Rodrigues, Maria
Seabra, Eurico Augusto
Silva, Luís
Colim, Ana
Viana, Rui
author_role author
author2 Cunha, Beatriz
Pereira, Ana
Rodrigues, Maria
Seabra, Eurico Augusto
Silva, Luís
Colim, Ana
Viana, Rui
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico de Viseu
dc.contributor.author.fl_str_mv Cruz, Ana
Cunha, Beatriz
Pereira, Ana
Rodrigues, Maria
Seabra, Eurico Augusto
Silva, Luís
Colim, Ana
Viana, Rui
dc.subject.por.fl_str_mv tibiotarsal joint
automation
device
rehabilitation
therapheet
topic tibiotarsal joint
automation
device
rehabilitation
therapheet
description Introduction: Currently, there are several types of devices and techniques for the rehabilitation of the tibiotarsal joint. However, complete and effective rehabilitation still falls short of expectations, since the existing devices are not adaptable to the level of torque and the number of repetitions and sessions to be performed, as these depend on each patient and on the stage at which he is finds. Objetives: To improve a mechatronic device for the rehabilitation of the tibiotarsal joint, the Therapheet. Methods: This study presents a review of the tibiotarsal joint rehabilitation protocols, as well as the classification of devices used for this purpose. Thus, the purpose is to improve the Therapheet, developed at the Department of Mechanical Engineering of the University of Minho, obtaining a viable, functional and safe rehabilitation device, standing out from the rest on the market, since it allows the execution of the six rehabilitation exercises. Results: It was obtained a prototype of equipment for rehabilitation of the tibiotarsal joint was obtained, proposing changes for improvement according to the specificities and requirements for such a device, having been subjected to a series of preliminary tests to verify its functionality, performance and suitability. The equipment proved to be functional, in terms of executing the ankle rehabilitation movements, however, it still manifests some flaws in terms of the user's stability, sudden movements, and above all dysfunctions arising from excess mass that make up its structure and limitations pneumatic technology adopted. Conclusions: The control of the amplitude of the characteristic angles of the movements of the foot is still done manually, so it would be significant to implement an automated system that would allow the control of the range of amplitude, according to the patient's rehabilitation phase. One option would be the implementation of a new technology, such as the insertion of servomotors.
publishDate 2020
dc.date.none.fl_str_mv 2020
2020-01-01T00:00:00Z
2021-02-24T17:10:32Z
2021-02-24T16:11:15Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.19/6629
url http://hdl.handle.net/10400.19/6629
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Cruz, A., Cunha, B., Pereira, A., Rodrigues, M., Seabra, E. A., Silva, L., Colim, A., & Viana, R. (2020). Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint. Millenium, 2(12), 13-23. DOI: 10.29352/mill0212.01.00324
10.29352/mill0212.01.00324
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Instituto Politécnico de Viseu
publisher.none.fl_str_mv Instituto Politécnico de Viseu
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130915633364992