Study and analysis of a new device for the rehabilitation of the tibiotarsal joint.
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0873-30152020000200013 |
Resumo: | Abstract Introduction: Currently, there are several types of devices and techniques for the rehabilitation of the tibiotarsal joint. However, complete and effective rehabilitation still falls short of expectations, since the existing devices are not adaptable to the level of torque and the number of repetitions and sessions to be performed, as these depend on each patient and on the stage at which he is finds. Objetives: To improve a mechatronic device for the rehabilitation of the tibiotarsal joint, the Therapheet. Methods: This study presents a review of the tibiotarsal joint rehabilitation protocols, as well as the classification of devices used for this purpose. Thus, the purpose is to improve the Therapheet, developed at the Department of Mechanical Engineering of the University of Minho, obtaining a viable, functional and safe rehabilitation device, standing out from the rest on the market, since it allows the execution of the six rehabilitation exercises. Results: It was obtained a prototype of equipment for rehabilitation of the tibiotarsal joint was obtained, proposing changes for improvement according to the specificities and requirements for such a device, having been subjected to a series of preliminary tests to verify its functionality, performance and suitability. The equipment proved to be functional, in terms of executing the ankle rehabilitation movements, however, it still manifests some flaws in terms of the user's stability, sudden movements, and above all dysfunctions arising from excess mass that make up its structure and limitations pneumatic technology adopted. Conclusions: The control of the amplitude of the characteristic angles of the movements of the foot is still done manually, so it would be significant to implement an automated system that would allow the control of the range of amplitude, according to the patient's rehabilitation phase. One option would be the implementation of a new technology, such as the insertion of servomotors. |
id |
RCAP_b79d8bf99825cfcd9b66c48a1230211d |
---|---|
oai_identifier_str |
oai:scielo:S0873-30152020000200013 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Study and analysis of a new device for the rehabilitation of the tibiotarsal joint.tibiotarsal jointautomationdevicerehabilitationtherapheetAbstract Introduction: Currently, there are several types of devices and techniques for the rehabilitation of the tibiotarsal joint. However, complete and effective rehabilitation still falls short of expectations, since the existing devices are not adaptable to the level of torque and the number of repetitions and sessions to be performed, as these depend on each patient and on the stage at which he is finds. Objetives: To improve a mechatronic device for the rehabilitation of the tibiotarsal joint, the Therapheet. Methods: This study presents a review of the tibiotarsal joint rehabilitation protocols, as well as the classification of devices used for this purpose. Thus, the purpose is to improve the Therapheet, developed at the Department of Mechanical Engineering of the University of Minho, obtaining a viable, functional and safe rehabilitation device, standing out from the rest on the market, since it allows the execution of the six rehabilitation exercises. Results: It was obtained a prototype of equipment for rehabilitation of the tibiotarsal joint was obtained, proposing changes for improvement according to the specificities and requirements for such a device, having been subjected to a series of preliminary tests to verify its functionality, performance and suitability. The equipment proved to be functional, in terms of executing the ankle rehabilitation movements, however, it still manifests some flaws in terms of the user's stability, sudden movements, and above all dysfunctions arising from excess mass that make up its structure and limitations pneumatic technology adopted. Conclusions: The control of the amplitude of the characteristic angles of the movements of the foot is still done manually, so it would be significant to implement an automated system that would allow the control of the range of amplitude, according to the patient's rehabilitation phase. One option would be the implementation of a new technology, such as the insertion of servomotors.Instituto Politécnico de Viseu (IPV)2020-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0873-30152020000200013Millenium - Journal of Education, Technologies, and Health n.12 2020reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0873-30152020000200013Cruz,AnaCunha,BeatrizPereira,AnaRodrigues,MariaSeabra,Eurico AugustoSilva,LuísColim,AnaViana,Ruiinfo:eu-repo/semantics/openAccess2024-02-06T17:10:05Zoai:scielo:S0873-30152020000200013Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:21:46.274394Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Study and analysis of a new device for the rehabilitation of the tibiotarsal joint. |
title |
Study and analysis of a new device for the rehabilitation of the tibiotarsal joint. |
spellingShingle |
Study and analysis of a new device for the rehabilitation of the tibiotarsal joint. Cruz,Ana tibiotarsal joint automation device rehabilitation therapheet |
title_short |
Study and analysis of a new device for the rehabilitation of the tibiotarsal joint. |
title_full |
Study and analysis of a new device for the rehabilitation of the tibiotarsal joint. |
title_fullStr |
Study and analysis of a new device for the rehabilitation of the tibiotarsal joint. |
title_full_unstemmed |
Study and analysis of a new device for the rehabilitation of the tibiotarsal joint. |
title_sort |
Study and analysis of a new device for the rehabilitation of the tibiotarsal joint. |
author |
Cruz,Ana |
author_facet |
Cruz,Ana Cunha,Beatriz Pereira,Ana Rodrigues,Maria Seabra,Eurico Augusto Silva,Luís Colim,Ana Viana,Rui |
author_role |
author |
author2 |
Cunha,Beatriz Pereira,Ana Rodrigues,Maria Seabra,Eurico Augusto Silva,Luís Colim,Ana Viana,Rui |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Cruz,Ana Cunha,Beatriz Pereira,Ana Rodrigues,Maria Seabra,Eurico Augusto Silva,Luís Colim,Ana Viana,Rui |
dc.subject.por.fl_str_mv |
tibiotarsal joint automation device rehabilitation therapheet |
topic |
tibiotarsal joint automation device rehabilitation therapheet |
description |
Abstract Introduction: Currently, there are several types of devices and techniques for the rehabilitation of the tibiotarsal joint. However, complete and effective rehabilitation still falls short of expectations, since the existing devices are not adaptable to the level of torque and the number of repetitions and sessions to be performed, as these depend on each patient and on the stage at which he is finds. Objetives: To improve a mechatronic device for the rehabilitation of the tibiotarsal joint, the Therapheet. Methods: This study presents a review of the tibiotarsal joint rehabilitation protocols, as well as the classification of devices used for this purpose. Thus, the purpose is to improve the Therapheet, developed at the Department of Mechanical Engineering of the University of Minho, obtaining a viable, functional and safe rehabilitation device, standing out from the rest on the market, since it allows the execution of the six rehabilitation exercises. Results: It was obtained a prototype of equipment for rehabilitation of the tibiotarsal joint was obtained, proposing changes for improvement according to the specificities and requirements for such a device, having been subjected to a series of preliminary tests to verify its functionality, performance and suitability. The equipment proved to be functional, in terms of executing the ankle rehabilitation movements, however, it still manifests some flaws in terms of the user's stability, sudden movements, and above all dysfunctions arising from excess mass that make up its structure and limitations pneumatic technology adopted. Conclusions: The control of the amplitude of the characteristic angles of the movements of the foot is still done manually, so it would be significant to implement an automated system that would allow the control of the range of amplitude, according to the patient's rehabilitation phase. One option would be the implementation of a new technology, such as the insertion of servomotors. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-08-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0873-30152020000200013 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0873-30152020000200013 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0873-30152020000200013 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Politécnico de Viseu (IPV) |
publisher.none.fl_str_mv |
Instituto Politécnico de Viseu (IPV) |
dc.source.none.fl_str_mv |
Millenium - Journal of Education, Technologies, and Health n.12 2020 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137302878879744 |