Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region

Detalhes bibliográficos
Autor(a) principal: Carmo, S. J. C. do
Data de Publicação: 2009
Outros Autores: Borges, F. I. G. M., Conde, C. A. N.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/12892
https://doi.org/10.1109/NSSMIC.2008.4774540
Resumo: The performance of a gas proportional scintillation counter filled with either pure Xe or Ar-Xe mixtures is described for the 0.1-10 keV X-ray energy range. It is shown that the spectra tail distortion exhibited by Xe filled gaseous detectors for soft X-rays below 2 keV is reduced if Ar-Xe mixtures are used. The peak-to-valley ratio increases by a factor of about 2 or 3 as the Xe concentration is reduced from 100% to 5%. Moreover, the energy resolutions for such mixtures are similar to the ones for pure Xe
id RCAP_8164763ba1df7563f870e336a28e5a54
oai_identifier_str oai:estudogeral.uc.pt:10316/12892
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray RegionArgon detectorsEnergy resolutionGas detectorsProportional gas scintillation detectorsX-ray detectorsX-ray spectroscopyXenon detectorsThe performance of a gas proportional scintillation counter filled with either pure Xe or Ar-Xe mixtures is described for the 0.1-10 keV X-ray energy range. It is shown that the spectra tail distortion exhibited by Xe filled gaseous detectors for soft X-rays below 2 keV is reduced if Ar-Xe mixtures are used. The peak-to-valley ratio increases by a factor of about 2 or 3 as the Xe concentration is reduced from 100% to 5%. Moreover, the energy resolutions for such mixtures are similar to the ones for pure XeIEEE2009-04info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/12892http://hdl.handle.net/10316/12892https://doi.org/10.1109/NSSMIC.2008.4774540engIEEE Transactions on Nuclear Science 56:2 (2009) 437-4400018-9499Carmo, S. J. C. doBorges, F. I. G. M.Conde, C. A. N.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-11-06T17:00:08Zoai:estudogeral.uc.pt:10316/12892Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:53.980230Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region
title Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region
spellingShingle Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region
Carmo, S. J. C. do
Argon detectors
Energy resolution
Gas detectors
Proportional gas scintillation detectors
X-ray detectors
X-ray spectroscopy
Xenon detectors
title_short Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region
title_full Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region
title_fullStr Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region
title_full_unstemmed Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region
title_sort Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region
author Carmo, S. J. C. do
author_facet Carmo, S. J. C. do
Borges, F. I. G. M.
Conde, C. A. N.
author_role author
author2 Borges, F. I. G. M.
Conde, C. A. N.
author2_role author
author
dc.contributor.author.fl_str_mv Carmo, S. J. C. do
Borges, F. I. G. M.
Conde, C. A. N.
dc.subject.por.fl_str_mv Argon detectors
Energy resolution
Gas detectors
Proportional gas scintillation detectors
X-ray detectors
X-ray spectroscopy
Xenon detectors
topic Argon detectors
Energy resolution
Gas detectors
Proportional gas scintillation detectors
X-ray detectors
X-ray spectroscopy
Xenon detectors
description The performance of a gas proportional scintillation counter filled with either pure Xe or Ar-Xe mixtures is described for the 0.1-10 keV X-ray energy range. It is shown that the spectra tail distortion exhibited by Xe filled gaseous detectors for soft X-rays below 2 keV is reduced if Ar-Xe mixtures are used. The peak-to-valley ratio increases by a factor of about 2 or 3 as the Xe concentration is reduced from 100% to 5%. Moreover, the energy resolutions for such mixtures are similar to the ones for pure Xe
publishDate 2009
dc.date.none.fl_str_mv 2009-04
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/12892
http://hdl.handle.net/10316/12892
https://doi.org/10.1109/NSSMIC.2008.4774540
url http://hdl.handle.net/10316/12892
https://doi.org/10.1109/NSSMIC.2008.4774540
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv IEEE Transactions on Nuclear Science 56:2 (2009) 437-440
0018-9499
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv IEEE
publisher.none.fl_str_mv IEEE
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133889404338176