Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
DOI: | 10.1109/NSSMIC.2008.4774540 |
Texto Completo: | http://hdl.handle.net/10316/12892 https://doi.org/10.1109/NSSMIC.2008.4774540 |
Resumo: | The performance of a gas proportional scintillation counter filled with either pure Xe or Ar-Xe mixtures is described for the 0.1-10 keV X-ray energy range. It is shown that the spectra tail distortion exhibited by Xe filled gaseous detectors for soft X-rays below 2 keV is reduced if Ar-Xe mixtures are used. The peak-to-valley ratio increases by a factor of about 2 or 3 as the Xe concentration is reduced from 100% to 5%. Moreover, the energy resolutions for such mixtures are similar to the ones for pure Xe |
id |
RCAP_8164763ba1df7563f870e336a28e5a54 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/12892 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray RegionArgon detectorsEnergy resolutionGas detectorsProportional gas scintillation detectorsX-ray detectorsX-ray spectroscopyXenon detectorsThe performance of a gas proportional scintillation counter filled with either pure Xe or Ar-Xe mixtures is described for the 0.1-10 keV X-ray energy range. It is shown that the spectra tail distortion exhibited by Xe filled gaseous detectors for soft X-rays below 2 keV is reduced if Ar-Xe mixtures are used. The peak-to-valley ratio increases by a factor of about 2 or 3 as the Xe concentration is reduced from 100% to 5%. Moreover, the energy resolutions for such mixtures are similar to the ones for pure XeIEEE2009-04info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/12892http://hdl.handle.net/10316/12892https://doi.org/10.1109/NSSMIC.2008.4774540engIEEE Transactions on Nuclear Science 56:2 (2009) 437-4400018-9499Carmo, S. J. C. doBorges, F. I. G. M.Conde, C. A. N.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-11-06T17:00:08Zoai:estudogeral.uc.pt:10316/12892Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:53.980230Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region |
title |
Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region |
spellingShingle |
Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region Carmo, S. J. C. do Argon detectors Energy resolution Gas detectors Proportional gas scintillation detectors X-ray detectors X-ray spectroscopy Xenon detectors Carmo, S. J. C. do Argon detectors Energy resolution Gas detectors Proportional gas scintillation detectors X-ray detectors X-ray spectroscopy Xenon detectors |
title_short |
Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region |
title_full |
Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region |
title_fullStr |
Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region |
title_full_unstemmed |
Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region |
title_sort |
Performance of Argon-Xenon Mixtures in a Gas Proportional Scintillation Counter for the 0.1–10 keV X-Ray Region |
author |
Carmo, S. J. C. do |
author_facet |
Carmo, S. J. C. do Carmo, S. J. C. do Borges, F. I. G. M. Conde, C. A. N. Borges, F. I. G. M. Conde, C. A. N. |
author_role |
author |
author2 |
Borges, F. I. G. M. Conde, C. A. N. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Carmo, S. J. C. do Borges, F. I. G. M. Conde, C. A. N. |
dc.subject.por.fl_str_mv |
Argon detectors Energy resolution Gas detectors Proportional gas scintillation detectors X-ray detectors X-ray spectroscopy Xenon detectors |
topic |
Argon detectors Energy resolution Gas detectors Proportional gas scintillation detectors X-ray detectors X-ray spectroscopy Xenon detectors |
description |
The performance of a gas proportional scintillation counter filled with either pure Xe or Ar-Xe mixtures is described for the 0.1-10 keV X-ray energy range. It is shown that the spectra tail distortion exhibited by Xe filled gaseous detectors for soft X-rays below 2 keV is reduced if Ar-Xe mixtures are used. The peak-to-valley ratio increases by a factor of about 2 or 3 as the Xe concentration is reduced from 100% to 5%. Moreover, the energy resolutions for such mixtures are similar to the ones for pure Xe |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-04 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/12892 http://hdl.handle.net/10316/12892 https://doi.org/10.1109/NSSMIC.2008.4774540 |
url |
http://hdl.handle.net/10316/12892 https://doi.org/10.1109/NSSMIC.2008.4774540 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
IEEE Transactions on Nuclear Science 56:2 (2009) 437-440 0018-9499 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
IEEE |
publisher.none.fl_str_mv |
IEEE |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1822183294130716672 |
dc.identifier.doi.none.fl_str_mv |
10.1109/NSSMIC.2008.4774540 |