Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/17154 |
Resumo: | Purpose: To evaluate the effect of an acoustic factor (AF) on the comparison of central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements with Orbscan II and Pentacam. Methods: The CCT and PCT at 1, 2, and 3 radial distances from the corneal apex were measured using Orbscan II and Pentacam in 22 right eyes of 22 healthy adults (7 men, 15 women). Three measures were obtained from each 1 of the 25 points measured and then compared to gauge the agreement between both devices at the corneal center and anular areas located at 1-, 2-, and 3-mm distances from the central measurement. Orbscan II readings were considered with and without an AF correction. Results: Pentacam provides statistically significant higher values than Orbscan II does at all the 25 locations analyzed (P,0.001). With a few exceptions, the average difference was fairly constant between 20 and 40 mm for all the corneal locations. A high correlation existed between central readings (r2=0.927; P,0.001) and average thickness at each one of the annular areas being analyzed (r2=0.897 at 1 mm, r2=0.876 at 2 mm, and r2=0.870 at 3 mm); Pentacam minus Orbscan II value averaged for all the points changed from 228610 to 22269 mm after the removal of the AF in Orbscan II. Conclusions: Central and peripheral measurements of the corneal thickness obtained with Orbscan II and Pentacam are significantly different. The removal of the AF in Orbscan II renders lower mean differences but decreases the agreement between both systems and potentially induces an overestimation of CCT and PCT by Orbsan II compared with Pentacam. |
id |
RCAP_85a7f1e82cdcc5d8c6e301df7ffd43f7 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/17154 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factorPachometryPeripheral corneal thicknessPentacamOrbscan IIBlandAltmanBland-AltmanScience & TechnologyPurpose: To evaluate the effect of an acoustic factor (AF) on the comparison of central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements with Orbscan II and Pentacam. Methods: The CCT and PCT at 1, 2, and 3 radial distances from the corneal apex were measured using Orbscan II and Pentacam in 22 right eyes of 22 healthy adults (7 men, 15 women). Three measures were obtained from each 1 of the 25 points measured and then compared to gauge the agreement between both devices at the corneal center and anular areas located at 1-, 2-, and 3-mm distances from the central measurement. Orbscan II readings were considered with and without an AF correction. Results: Pentacam provides statistically significant higher values than Orbscan II does at all the 25 locations analyzed (P,0.001). With a few exceptions, the average difference was fairly constant between 20 and 40 mm for all the corneal locations. A high correlation existed between central readings (r2=0.927; P,0.001) and average thickness at each one of the annular areas being analyzed (r2=0.897 at 1 mm, r2=0.876 at 2 mm, and r2=0.870 at 3 mm); Pentacam minus Orbscan II value averaged for all the points changed from 228610 to 22269 mm after the removal of the AF in Orbscan II. Conclusions: Central and peripheral measurements of the corneal thickness obtained with Orbscan II and Pentacam are significantly different. The removal of the AF in Orbscan II renders lower mean differences but decreases the agreement between both systems and potentially induces an overestimation of CCT and PCT by Orbsan II compared with Pentacam.Supported by national grant PI081380 from Instituto de Salud Carlos III, Spain granted to Ocular Surface and Contact Lens Research Group GI-1750.Lippincott, Williams & WilkinsUniversidade do MinhoGonzález-Pérez, JavierGonzález-Méijome, José ManuelRodríguez Ares, María T.Parafita, Manuel A.20112011-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/17154eng1542-232110.1097/ICL.0b013e3182323dcf21983548http://journals.lww.com/pages/default.aspxinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:00:38Zoai:repositorium.sdum.uminho.pt:1822/17154Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:50:29.833878Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor |
title |
Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor |
spellingShingle |
Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor González-Pérez, Javier Pachometry Peripheral corneal thickness Pentacam Orbscan II Bland Altman Bland-Altman Science & Technology |
title_short |
Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor |
title_full |
Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor |
title_fullStr |
Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor |
title_full_unstemmed |
Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor |
title_sort |
Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor |
author |
González-Pérez, Javier |
author_facet |
González-Pérez, Javier González-Méijome, José Manuel Rodríguez Ares, María T. Parafita, Manuel A. |
author_role |
author |
author2 |
González-Méijome, José Manuel Rodríguez Ares, María T. Parafita, Manuel A. |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
González-Pérez, Javier González-Méijome, José Manuel Rodríguez Ares, María T. Parafita, Manuel A. |
dc.subject.por.fl_str_mv |
Pachometry Peripheral corneal thickness Pentacam Orbscan II Bland Altman Bland-Altman Science & Technology |
topic |
Pachometry Peripheral corneal thickness Pentacam Orbscan II Bland Altman Bland-Altman Science & Technology |
description |
Purpose: To evaluate the effect of an acoustic factor (AF) on the comparison of central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements with Orbscan II and Pentacam. Methods: The CCT and PCT at 1, 2, and 3 radial distances from the corneal apex were measured using Orbscan II and Pentacam in 22 right eyes of 22 healthy adults (7 men, 15 women). Three measures were obtained from each 1 of the 25 points measured and then compared to gauge the agreement between both devices at the corneal center and anular areas located at 1-, 2-, and 3-mm distances from the central measurement. Orbscan II readings were considered with and without an AF correction. Results: Pentacam provides statistically significant higher values than Orbscan II does at all the 25 locations analyzed (P,0.001). With a few exceptions, the average difference was fairly constant between 20 and 40 mm for all the corneal locations. A high correlation existed between central readings (r2=0.927; P,0.001) and average thickness at each one of the annular areas being analyzed (r2=0.897 at 1 mm, r2=0.876 at 2 mm, and r2=0.870 at 3 mm); Pentacam minus Orbscan II value averaged for all the points changed from 228610 to 22269 mm after the removal of the AF in Orbscan II. Conclusions: Central and peripheral measurements of the corneal thickness obtained with Orbscan II and Pentacam are significantly different. The removal of the AF in Orbscan II renders lower mean differences but decreases the agreement between both systems and potentially induces an overestimation of CCT and PCT by Orbsan II compared with Pentacam. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011 2011-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/17154 |
url |
http://hdl.handle.net/1822/17154 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1542-2321 10.1097/ICL.0b013e3182323dcf 21983548 http://journals.lww.com/pages/default.aspx |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Lippincott, Williams & Wilkins |
publisher.none.fl_str_mv |
Lippincott, Williams & Wilkins |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132274020581376 |