Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment

Detalhes bibliográficos
Autor(a) principal: Varella, Roberto Aliandro
Data de Publicação: 2018
Outros Autores: Giechaskiel, Barouch, Sousa, Luís, Duarte, Gonçalo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.21/8906
Resumo: Real-driving emissions (RDE) testing with portable emissions measurement systems (PEMS) during the type approval and in-service conformity of light-duty vehicles was recently introduced in the European Union legislation. In this paper, three PEMS were compared with laboratory analyzers connected to the tailpipe and the dilution tunnel. The tests were conducted with two Euro 6 vehicles (one gasoline and one diesel) performing the World harmonized Light vehicles Test Cycle (WLTC) and a pre-recorded RDE cycle on a chassis dynamometer. The results showed that the differences of the PEMS gas analyzers compared to the laboratory references were typically within 2% for CO2 and 5% for NOx. The CO2 and NOx mass emissions were within 10% and 15%, respectively, with only a few exceptions. The exhaust flow rate measurements were within 10% at low speeds (urban conditions), and 5% at higher speeds. These results confirm the legislated permitted tolerances and the 2017 PEMS uncertainty estimates.
id RCAP_898c9a572436b590c3f3a5f4448b2608
oai_identifier_str oai:repositorio.ipl.pt:10400.21/8906
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipmentPortable emissions measurement system (PEMS)Worldwide harmonized light vehicles test cycle (WLTC)Real driving emissions (RDE)Conformity factor (CF)Validation testCO2NOxExhaust flow meter (EFM)Measurement uncertaintyReal-driving emissions (RDE) testing with portable emissions measurement systems (PEMS) during the type approval and in-service conformity of light-duty vehicles was recently introduced in the European Union legislation. In this paper, three PEMS were compared with laboratory analyzers connected to the tailpipe and the dilution tunnel. The tests were conducted with two Euro 6 vehicles (one gasoline and one diesel) performing the World harmonized Light vehicles Test Cycle (WLTC) and a pre-recorded RDE cycle on a chassis dynamometer. The results showed that the differences of the PEMS gas analyzers compared to the laboratory references were typically within 2% for CO2 and 5% for NOx. The CO2 and NOx mass emissions were within 10% and 15%, respectively, with only a few exceptions. The exhaust flow rate measurements were within 10% at low speeds (urban conditions), and 5% at higher speeds. These results confirm the legislated permitted tolerances and the 2017 PEMS uncertainty estimates.MDPIRCIPLVarella, Roberto AliandroGiechaskiel, BarouchSousa, LuísDuarte, Gonçalo2018-10-10T13:34:29Z2018-09-122018-09-12T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/8906engVARELLA, Roberto Aliandro; [et al] – Comparison of Portable Emissions Measurement Systems (PEMS) with Laboratory Grade Equipment. Applied Sciences - Basel. ISSN 2076-3417. Vol. 8, N.º 9 (2018), pp. 1-122076-341710.3390/app8091633info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T09:56:57Zoai:repositorio.ipl.pt:10400.21/8906Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:17:35.886531Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment
title Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment
spellingShingle Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment
Varella, Roberto Aliandro
Portable emissions measurement system (PEMS)
Worldwide harmonized light vehicles test cycle (WLTC)
Real driving emissions (RDE)
Conformity factor (CF)
Validation test
CO2
NOx
Exhaust flow meter (EFM)
Measurement uncertainty
title_short Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment
title_full Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment
title_fullStr Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment
title_full_unstemmed Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment
title_sort Comparison of portable emissions measurement systems (PEMS) with laboratory grade equipment
author Varella, Roberto Aliandro
author_facet Varella, Roberto Aliandro
Giechaskiel, Barouch
Sousa, Luís
Duarte, Gonçalo
author_role author
author2 Giechaskiel, Barouch
Sousa, Luís
Duarte, Gonçalo
author2_role author
author
author
dc.contributor.none.fl_str_mv RCIPL
dc.contributor.author.fl_str_mv Varella, Roberto Aliandro
Giechaskiel, Barouch
Sousa, Luís
Duarte, Gonçalo
dc.subject.por.fl_str_mv Portable emissions measurement system (PEMS)
Worldwide harmonized light vehicles test cycle (WLTC)
Real driving emissions (RDE)
Conformity factor (CF)
Validation test
CO2
NOx
Exhaust flow meter (EFM)
Measurement uncertainty
topic Portable emissions measurement system (PEMS)
Worldwide harmonized light vehicles test cycle (WLTC)
Real driving emissions (RDE)
Conformity factor (CF)
Validation test
CO2
NOx
Exhaust flow meter (EFM)
Measurement uncertainty
description Real-driving emissions (RDE) testing with portable emissions measurement systems (PEMS) during the type approval and in-service conformity of light-duty vehicles was recently introduced in the European Union legislation. In this paper, three PEMS were compared with laboratory analyzers connected to the tailpipe and the dilution tunnel. The tests were conducted with two Euro 6 vehicles (one gasoline and one diesel) performing the World harmonized Light vehicles Test Cycle (WLTC) and a pre-recorded RDE cycle on a chassis dynamometer. The results showed that the differences of the PEMS gas analyzers compared to the laboratory references were typically within 2% for CO2 and 5% for NOx. The CO2 and NOx mass emissions were within 10% and 15%, respectively, with only a few exceptions. The exhaust flow rate measurements were within 10% at low speeds (urban conditions), and 5% at higher speeds. These results confirm the legislated permitted tolerances and the 2017 PEMS uncertainty estimates.
publishDate 2018
dc.date.none.fl_str_mv 2018-10-10T13:34:29Z
2018-09-12
2018-09-12T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/8906
url http://hdl.handle.net/10400.21/8906
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv VARELLA, Roberto Aliandro; [et al] – Comparison of Portable Emissions Measurement Systems (PEMS) with Laboratory Grade Equipment. Applied Sciences - Basel. ISSN 2076-3417. Vol. 8, N.º 9 (2018), pp. 1-12
2076-3417
10.3390/app8091633
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133438664507392