Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates.
Autor(a) principal: | |
---|---|
Data de Publicação: | 2001 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10174/3420 |
Resumo: | Ventilation is one of the most important tools for controlling the greenhouse climate. The air exchange between inside and outside of a greenhouse influences the environmental conditions such as temperature, humidity and carbon dioxide concentration of the enclosure which affect the development and production of the crop. In winter, ventilation must remove the excess water vapour while during summer cooling is the main reason for ventilation. Natural ventilation is the result of the action of two natural forces, wind and thermal buoyancy. Some models of natural ventilation are described. Various techniques have been used to determine ventilation and leakage rates such as tracer gas and energy balances. The energy balance is based on the energy removed by ventilation from the greenhouse as a way of preventing excessively high temperatures. Tracer gas techniques are based on mass balances and are used mostly to measure ventilation rates directly in greenhouses. It seems that the tracer gas technique gives greater accuracy than the energy balance at low ventilation rates. The difficulty of using the energy balance is the large number of variables involved and the required accuracy in their measurement. In this study, ventilation rate was measured using the decay tracer gas method for leeward ventilators opened to 10 and 20%. It was found that wind speed had a strong influence on ventilation rates and a linear relation was obtained. Ventilation rates were predicted using the energy balance method and a model based on wind and buoyancy forces proposed by Boulard and Baille (1995), assuming that total ventilation is due to the combined effect of both natural forces. It was found that the energy balance gives better results for higher ventilator apertures. In the case of the model based on wind and buoyancy forces good agreement was obtained between measured and predicted ventilation rates for both ventilator positions. |
id |
RCAP_8c79bd0169568e2390ed43dbabe518d0 |
---|---|
oai_identifier_str |
oai:dspace.uevora.pt:10174/3420 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates.natural ventilationenergy balancetracer gasgreenhouseVentilation is one of the most important tools for controlling the greenhouse climate. The air exchange between inside and outside of a greenhouse influences the environmental conditions such as temperature, humidity and carbon dioxide concentration of the enclosure which affect the development and production of the crop. In winter, ventilation must remove the excess water vapour while during summer cooling is the main reason for ventilation. Natural ventilation is the result of the action of two natural forces, wind and thermal buoyancy. Some models of natural ventilation are described. Various techniques have been used to determine ventilation and leakage rates such as tracer gas and energy balances. The energy balance is based on the energy removed by ventilation from the greenhouse as a way of preventing excessively high temperatures. Tracer gas techniques are based on mass balances and are used mostly to measure ventilation rates directly in greenhouses. It seems that the tracer gas technique gives greater accuracy than the energy balance at low ventilation rates. The difficulty of using the energy balance is the large number of variables involved and the required accuracy in their measurement. In this study, ventilation rate was measured using the decay tracer gas method for leeward ventilators opened to 10 and 20%. It was found that wind speed had a strong influence on ventilation rates and a linear relation was obtained. Ventilation rates were predicted using the energy balance method and a model based on wind and buoyancy forces proposed by Boulard and Baille (1995), assuming that total ventilation is due to the combined effect of both natural forces. It was found that the energy balance gives better results for higher ventilator apertures. In the case of the model based on wind and buoyancy forces good agreement was obtained between measured and predicted ventilation rates for both ventilator positions.2012-01-12T11:21:42Z2012-01-122001-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10174/3420http://hdl.handle.net/10174/3420engBAPTISTA FJ, BAILEY BJ e MENESES JF. 2001. Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. Paper nº 3019, Proc. of the Simposium Agribuilding 2001, Campinas, Brasil, 136-151.Partilhar com ICAAMfb@uevora.ptndjmeneses@isa.utl.pt580Baptista, F.J.Bailey, B.J.Meneses, J.F.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-03T18:40:30Zoai:dspace.uevora.pt:10174/3420Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:58:50.206881Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. |
title |
Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. |
spellingShingle |
Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. Baptista, F.J. natural ventilation energy balance tracer gas greenhouse |
title_short |
Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. |
title_full |
Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. |
title_fullStr |
Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. |
title_full_unstemmed |
Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. |
title_sort |
Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. |
author |
Baptista, F.J. |
author_facet |
Baptista, F.J. Bailey, B.J. Meneses, J.F. |
author_role |
author |
author2 |
Bailey, B.J. Meneses, J.F. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Baptista, F.J. Bailey, B.J. Meneses, J.F. |
dc.subject.por.fl_str_mv |
natural ventilation energy balance tracer gas greenhouse |
topic |
natural ventilation energy balance tracer gas greenhouse |
description |
Ventilation is one of the most important tools for controlling the greenhouse climate. The air exchange between inside and outside of a greenhouse influences the environmental conditions such as temperature, humidity and carbon dioxide concentration of the enclosure which affect the development and production of the crop. In winter, ventilation must remove the excess water vapour while during summer cooling is the main reason for ventilation. Natural ventilation is the result of the action of two natural forces, wind and thermal buoyancy. Some models of natural ventilation are described. Various techniques have been used to determine ventilation and leakage rates such as tracer gas and energy balances. The energy balance is based on the energy removed by ventilation from the greenhouse as a way of preventing excessively high temperatures. Tracer gas techniques are based on mass balances and are used mostly to measure ventilation rates directly in greenhouses. It seems that the tracer gas technique gives greater accuracy than the energy balance at low ventilation rates. The difficulty of using the energy balance is the large number of variables involved and the required accuracy in their measurement. In this study, ventilation rate was measured using the decay tracer gas method for leeward ventilators opened to 10 and 20%. It was found that wind speed had a strong influence on ventilation rates and a linear relation was obtained. Ventilation rates were predicted using the energy balance method and a model based on wind and buoyancy forces proposed by Boulard and Baille (1995), assuming that total ventilation is due to the combined effect of both natural forces. It was found that the energy balance gives better results for higher ventilator apertures. In the case of the model based on wind and buoyancy forces good agreement was obtained between measured and predicted ventilation rates for both ventilator positions. |
publishDate |
2001 |
dc.date.none.fl_str_mv |
2001-01-01T00:00:00Z 2012-01-12T11:21:42Z 2012-01-12 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10174/3420 http://hdl.handle.net/10174/3420 |
url |
http://hdl.handle.net/10174/3420 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
BAPTISTA FJ, BAILEY BJ e MENESES JF. 2001. Natural ventilation of greenhouses. Comparison of measured and predicted ventilation rates. Paper nº 3019, Proc. of the Simposium Agribuilding 2001, Campinas, Brasil, 136-151. Partilhar com ICAAM fb@uevora.pt nd jmeneses@isa.utl.pt 580 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799136471575166976 |