Carbon film electrodes for oxidase-based enzyme sensors in food analysis

Detalhes bibliográficos
Autor(a) principal: Luca, S. De
Data de Publicação: 2005
Outros Autores: Florescu, M., Ghica, M. E., Lupu, A., Palleschi, G., Brett, C. M. A., Compagnone, D.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/5095
https://doi.org/10.1016/j.talanta.2005.06.017
Resumo: Carbon film resistor electrodes have been evaluated as transducers for the development of multiple oxidase-based enzyme electrode biosensors. The resistor electrodes were first modified with Prussian Blue (PB) and then covered by a layer of covalently immobilized enzyme. Electrochemical impedance spectroscopy was used to characterize the interfacial behaviour of the Prussian Blue modified and enzyme electrodes; the spectra demonstrated that the access of the substrates is essentially unaltered by application of the enzyme layer. These enzyme electrodes were used to detect the substrate of the oxidase (glucose, ethanol, lactate, glutamate) via reduction of hydrogen peroxide at +50 mV versus Ag/AgCl in the low micromolar range. Response times were 1-2 min. Finally, the glucose, ethanol and lactate electrochemical biosensors were used to analyse complex food matrices--must, wine and yoghurt. Data obtained by the single standard addition method were compared with a spectrophotometric reference method and showed good correlation, indicating that the electrodes are suitable for food analysis.
id RCAP_8e4a06f6138b9a64605272d2d93ccf5a
oai_identifier_str oai:estudogeral.uc.pt:10316/5095
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Carbon film electrodes for oxidase-based enzyme sensors in food analysisOxidase enzymesCarbon film electrodesPrussian Blue mediatorFood analysisCarbon film resistor electrodes have been evaluated as transducers for the development of multiple oxidase-based enzyme electrode biosensors. The resistor electrodes were first modified with Prussian Blue (PB) and then covered by a layer of covalently immobilized enzyme. Electrochemical impedance spectroscopy was used to characterize the interfacial behaviour of the Prussian Blue modified and enzyme electrodes; the spectra demonstrated that the access of the substrates is essentially unaltered by application of the enzyme layer. These enzyme electrodes were used to detect the substrate of the oxidase (glucose, ethanol, lactate, glutamate) via reduction of hydrogen peroxide at +50 mV versus Ag/AgCl in the low micromolar range. Response times were 1-2 min. Finally, the glucose, ethanol and lactate electrochemical biosensors were used to analyse complex food matrices--must, wine and yoghurt. Data obtained by the single standard addition method were compared with a spectrophotometric reference method and showed good correlation, indicating that the electrodes are suitable for food analysis.http://www.sciencedirect.com/science/article/B6THP-4GNTFGP-2/1/087dc22044a84cfb2a1badf317934bca2005info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/5095http://hdl.handle.net/10316/5095https://doi.org/10.1016/j.talanta.2005.06.017engTalanta. 68:2 (2005) 171-178Luca, S. DeFlorescu, M.Ghica, M. E.Lupu, A.Palleschi, G.Brett, C. M. A.Compagnone, D.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-05-25T01:32:15Zoai:estudogeral.uc.pt:10316/5095Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:01:37.831177Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Carbon film electrodes for oxidase-based enzyme sensors in food analysis
title Carbon film electrodes for oxidase-based enzyme sensors in food analysis
spellingShingle Carbon film electrodes for oxidase-based enzyme sensors in food analysis
Luca, S. De
Oxidase enzymes
Carbon film electrodes
Prussian Blue mediator
Food analysis
title_short Carbon film electrodes for oxidase-based enzyme sensors in food analysis
title_full Carbon film electrodes for oxidase-based enzyme sensors in food analysis
title_fullStr Carbon film electrodes for oxidase-based enzyme sensors in food analysis
title_full_unstemmed Carbon film electrodes for oxidase-based enzyme sensors in food analysis
title_sort Carbon film electrodes for oxidase-based enzyme sensors in food analysis
author Luca, S. De
author_facet Luca, S. De
Florescu, M.
Ghica, M. E.
Lupu, A.
Palleschi, G.
Brett, C. M. A.
Compagnone, D.
author_role author
author2 Florescu, M.
Ghica, M. E.
Lupu, A.
Palleschi, G.
Brett, C. M. A.
Compagnone, D.
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Luca, S. De
Florescu, M.
Ghica, M. E.
Lupu, A.
Palleschi, G.
Brett, C. M. A.
Compagnone, D.
dc.subject.por.fl_str_mv Oxidase enzymes
Carbon film electrodes
Prussian Blue mediator
Food analysis
topic Oxidase enzymes
Carbon film electrodes
Prussian Blue mediator
Food analysis
description Carbon film resistor electrodes have been evaluated as transducers for the development of multiple oxidase-based enzyme electrode biosensors. The resistor electrodes were first modified with Prussian Blue (PB) and then covered by a layer of covalently immobilized enzyme. Electrochemical impedance spectroscopy was used to characterize the interfacial behaviour of the Prussian Blue modified and enzyme electrodes; the spectra demonstrated that the access of the substrates is essentially unaltered by application of the enzyme layer. These enzyme electrodes were used to detect the substrate of the oxidase (glucose, ethanol, lactate, glutamate) via reduction of hydrogen peroxide at +50 mV versus Ag/AgCl in the low micromolar range. Response times were 1-2 min. Finally, the glucose, ethanol and lactate electrochemical biosensors were used to analyse complex food matrices--must, wine and yoghurt. Data obtained by the single standard addition method were compared with a spectrophotometric reference method and showed good correlation, indicating that the electrodes are suitable for food analysis.
publishDate 2005
dc.date.none.fl_str_mv 2005
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/5095
http://hdl.handle.net/10316/5095
https://doi.org/10.1016/j.talanta.2005.06.017
url http://hdl.handle.net/10316/5095
https://doi.org/10.1016/j.talanta.2005.06.017
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Talanta. 68:2 (2005) 171-178
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv aplication/PDF
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133907377979392