Resumo: | The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedback due to the additional scintillation produced in the electron avalanche process at the MSP anodes, in the absence of quenching. A low-photoelectron collection efficiency is achieved in the gas atmosphere, resulting in a scintillation conversion efficiency that is about a factor of 5 lower than that achieved with PMT-based GPSCs. However, energy resolutions of 11% for 5.9 keV X-rays are achieved with this detector. |
id |
RCAP_9019ee2e1a289b4f71bbee080524ef1c |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/4472 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
The gas proportional scintillation counter/microstrip gas chamber hybrid detectorGas scintillation counterCsI photocathodeThe gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedback due to the additional scintillation produced in the electron avalanche process at the MSP anodes, in the absence of quenching. A low-photoelectron collection efficiency is achieved in the gas atmosphere, resulting in a scintillation conversion efficiency that is about a factor of 5 lower than that achieved with PMT-based GPSCs. However, energy resolutions of 11% for 5.9 keV X-rays are achieved with this detector.http://www.sciencedirect.com/science/article/B6TJM-486BN6Y-M/1/4da741da1d82059bc939bc52156b65692003info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/4472http://hdl.handle.net/10316/4472https://doi.org/10.1016/S0168-9002(03)01058-1engNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 505:1-2 (2003) 228-232Freitas, D. S. A. P.Veloso, J. F. C. A.Monteiro, C. M. B.Santos, J. M. F. dosConde, C. A. N.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-05-25T03:03:24Zoai:estudogeral.uc.pt:10316/4472Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:45.051659Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector |
title |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector |
spellingShingle |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector Freitas, D. S. A. P. Gas scintillation counter CsI photocathode |
title_short |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector |
title_full |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector |
title_fullStr |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector |
title_full_unstemmed |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector |
title_sort |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector |
author |
Freitas, D. S. A. P. |
author_facet |
Freitas, D. S. A. P. Veloso, J. F. C. A. Monteiro, C. M. B. Santos, J. M. F. dos Conde, C. A. N. |
author_role |
author |
author2 |
Veloso, J. F. C. A. Monteiro, C. M. B. Santos, J. M. F. dos Conde, C. A. N. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Freitas, D. S. A. P. Veloso, J. F. C. A. Monteiro, C. M. B. Santos, J. M. F. dos Conde, C. A. N. |
dc.subject.por.fl_str_mv |
Gas scintillation counter CsI photocathode |
topic |
Gas scintillation counter CsI photocathode |
description |
The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedback due to the additional scintillation produced in the electron avalanche process at the MSP anodes, in the absence of quenching. A low-photoelectron collection efficiency is achieved in the gas atmosphere, resulting in a scintillation conversion efficiency that is about a factor of 5 lower than that achieved with PMT-based GPSCs. However, energy resolutions of 11% for 5.9 keV X-rays are achieved with this detector. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/4472 http://hdl.handle.net/10316/4472 https://doi.org/10.1016/S0168-9002(03)01058-1 |
url |
http://hdl.handle.net/10316/4472 https://doi.org/10.1016/S0168-9002(03)01058-1 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 505:1-2 (2003) 228-232 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
aplication/PDF |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133888365199360 |