A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in Portugal
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://doi.org/10.46885/roentgen.v2i2.53 |
Resumo: | Most interventional electrophysiology procedures require fluoroscopy therefore exposing all intervening parties to ionizing radiation. The use of diagnostic reference levels (DRLs) can be a useful tool to promote dose optimization. The main objective of this study was to investigate the exposure doses, determining the DRLs.An institutional study, cross-sectional and retrospective was carried out, through the review of electrophysiological diagnostic and/or treatment study procedures and the implantation of cardiac devices, performed between May 23, 2018 and February 19, 2020. The procedures were distributed in groups according to their complexity and determined their diagnostic reference levels for the dose descriptors Cumulative air kerma (CK, mGy) and Air kerma area product (PKA, mGy.cm2). This study included 516 procedures. The determined DRLs were: electrophysiological diagnostic study (12mGy and 3,5Gy.cm2); electrophysiological study with ablation in right heart cavities (62mGy and 20Gy.cm2); electrophysiological study with ablation in left heart cavities (87,5mGy and 32Gy.cm2); atrial fibrillation ablation (103mGy and 34Gy.cm2); implantation of a cardioverter-defibrillator or pacemaker with a passive fixation lead (7mGy and 2,5Gy.cm2) or active (10mGy and 3Gy.cm2) and with two passive fixation leads (9mGy and 3Gy.cm2), or active (15mGy and 4,5Gy.cm2), or an active and one passive (12mGy and 4Gy.cm2); implantation of a cardiac resynchronization device (158,5mGy and 38Gy.cm2) or upgrade (98mGy and 36Gy.cm2). The most complex procedures were those with the highest DRLs.It was determined that most of the DRLs found are below the values published in the literature. |
id |
RCAP_928e88a94cc76bb8fe6d61ad802b4f6a |
---|---|
oai_identifier_str |
oai:roentgen.pt:article/53 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in PortugalContributo para o estabelecimento de níveis de referência de diagnóstico em eletrofisiologia de intervenção: estudo de um centro em PortugalInterventional electrophysiologyDRLsRadiological protectionEletrofisiologia de intervençãoNRDProteção radiológicaMost interventional electrophysiology procedures require fluoroscopy therefore exposing all intervening parties to ionizing radiation. The use of diagnostic reference levels (DRLs) can be a useful tool to promote dose optimization. The main objective of this study was to investigate the exposure doses, determining the DRLs.An institutional study, cross-sectional and retrospective was carried out, through the review of electrophysiological diagnostic and/or treatment study procedures and the implantation of cardiac devices, performed between May 23, 2018 and February 19, 2020. The procedures were distributed in groups according to their complexity and determined their diagnostic reference levels for the dose descriptors Cumulative air kerma (CK, mGy) and Air kerma area product (PKA, mGy.cm2). This study included 516 procedures. The determined DRLs were: electrophysiological diagnostic study (12mGy and 3,5Gy.cm2); electrophysiological study with ablation in right heart cavities (62mGy and 20Gy.cm2); electrophysiological study with ablation in left heart cavities (87,5mGy and 32Gy.cm2); atrial fibrillation ablation (103mGy and 34Gy.cm2); implantation of a cardioverter-defibrillator or pacemaker with a passive fixation lead (7mGy and 2,5Gy.cm2) or active (10mGy and 3Gy.cm2) and with two passive fixation leads (9mGy and 3Gy.cm2), or active (15mGy and 4,5Gy.cm2), or an active and one passive (12mGy and 4Gy.cm2); implantation of a cardiac resynchronization device (158,5mGy and 38Gy.cm2) or upgrade (98mGy and 36Gy.cm2). The most complex procedures were those with the highest DRLs.It was determined that most of the DRLs found are below the values published in the literature.A maioria dos procedimentos eletrofisiologia de intervenção necessitam de fluoroscopia expondo à radiação ionizante todos os intervenientes. O recurso a níveis de referência de diagnóstico (NRD) pode ser uma ferramenta profícua para promover a otimização de dose. O principal objetivo deste estudo consistiu em investigar as doses de exposição, determinando os NRD. Realizou-se um estudo institucional, transversal e retrospetivo, através da revisão dos procedimentos de estudos eletrofisiológicos de diagnóstico e/ou tratamento e de implantação de dispositivos cardíacos, realizados entre 23 de maio de 2018 e 19 de fevereiro de 2020. Os procedimentos foram distribuídos em grupos de acordo com a sua complexidade e aferidos os seus NRD para os descritores de dose Cumulative air kerma (CK, mGy) e Air kerma area product (PKA, mGy.cm2). Este estudo incluiu 516 procedimentos. Os NRD determinados foram: estudo eletrofisiológico de diagnóstico (12mGy e 3,5Gy.cm2); estudo eletrofisiológico com ablação em cavidades cardíacas direitas (62mGy e 20Gy.cm2); ou em cavidades cardíacas esquerdas (87,5mGy e 32Gy.cm2); ablação por fibrilhação auricular (103mGy e 34Gy.cm2); implantação de cardioversor-desfibrilhador ou pacemaker com um eletrocateter de fixação passiva (7mGy e 2,5Gy.cm2), ou ativa (10mGy e 3Gy.cm2), e com dois eletrocateteres de fixação passiva (9mGy e 3Gy.cm2), ou ativa (15mGy e 4,5Gy.cm2), ou um ativo e um passivo (12mGy e 4Gy.cm2); implantação de dispositivo de ressincronização cardíaca (158,5mGy e 35Gy.cm2) ou upgrade (98mGy e 36Gy.cm2). Os procedimentos mais complexos foram os que apresentaram os NRD mais elevados.Verificou-se que a maioria dos NRD determinados se situa abaixo dos valores publicados na literatura.NUCLIRAD - Núcleo de Desenvolvimento dos Técnicos de Radiologia2021-07-19info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.46885/roentgen.v2i2.53https://doi.org/10.46885/roentgen.v2i2.53ROENTGEN-Scientific Journal of Radiological Techniques; Vol. 2 No. 2 (2021): One Profession, different paths; 11-19ROENTGEN-Revista Científica das Técnicas Radiológicas; v. 2 n. 2 (2021): Uma Profissão, diferentes caminhos; 11-192184-7657reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPporhttps://roentgen.pt/index.php/Principal/article/view/53https://roentgen.pt/index.php/Principal/article/view/53/50Direitos de Autor (c) 2021 ROENTGEN-Revista Científica das Técnicas Radiológicasinfo:eu-repo/semantics/openAccessVideira, SaraPereira, José Manuel2023-12-20T16:17:07Zoai:roentgen.pt:article/53Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:55:19.648149Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in Portugal Contributo para o estabelecimento de níveis de referência de diagnóstico em eletrofisiologia de intervenção: estudo de um centro em Portugal |
title |
A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in Portugal |
spellingShingle |
A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in Portugal Videira, Sara Interventional electrophysiology DRLs Radiological protection Eletrofisiologia de intervenção NRD Proteção radiológica |
title_short |
A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in Portugal |
title_full |
A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in Portugal |
title_fullStr |
A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in Portugal |
title_full_unstemmed |
A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in Portugal |
title_sort |
A contribution to the establishment of diagnostic reference levels in intervention electrophysiology: study from a center in Portugal |
author |
Videira, Sara |
author_facet |
Videira, Sara Pereira, José Manuel |
author_role |
author |
author2 |
Pereira, José Manuel |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Videira, Sara Pereira, José Manuel |
dc.subject.por.fl_str_mv |
Interventional electrophysiology DRLs Radiological protection Eletrofisiologia de intervenção NRD Proteção radiológica |
topic |
Interventional electrophysiology DRLs Radiological protection Eletrofisiologia de intervenção NRD Proteção radiológica |
description |
Most interventional electrophysiology procedures require fluoroscopy therefore exposing all intervening parties to ionizing radiation. The use of diagnostic reference levels (DRLs) can be a useful tool to promote dose optimization. The main objective of this study was to investigate the exposure doses, determining the DRLs.An institutional study, cross-sectional and retrospective was carried out, through the review of electrophysiological diagnostic and/or treatment study procedures and the implantation of cardiac devices, performed between May 23, 2018 and February 19, 2020. The procedures were distributed in groups according to their complexity and determined their diagnostic reference levels for the dose descriptors Cumulative air kerma (CK, mGy) and Air kerma area product (PKA, mGy.cm2). This study included 516 procedures. The determined DRLs were: electrophysiological diagnostic study (12mGy and 3,5Gy.cm2); electrophysiological study with ablation in right heart cavities (62mGy and 20Gy.cm2); electrophysiological study with ablation in left heart cavities (87,5mGy and 32Gy.cm2); atrial fibrillation ablation (103mGy and 34Gy.cm2); implantation of a cardioverter-defibrillator or pacemaker with a passive fixation lead (7mGy and 2,5Gy.cm2) or active (10mGy and 3Gy.cm2) and with two passive fixation leads (9mGy and 3Gy.cm2), or active (15mGy and 4,5Gy.cm2), or an active and one passive (12mGy and 4Gy.cm2); implantation of a cardiac resynchronization device (158,5mGy and 38Gy.cm2) or upgrade (98mGy and 36Gy.cm2). The most complex procedures were those with the highest DRLs.It was determined that most of the DRLs found are below the values published in the literature. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-07-19 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://doi.org/10.46885/roentgen.v2i2.53 https://doi.org/10.46885/roentgen.v2i2.53 |
url |
https://doi.org/10.46885/roentgen.v2i2.53 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://roentgen.pt/index.php/Principal/article/view/53 https://roentgen.pt/index.php/Principal/article/view/53/50 |
dc.rights.driver.fl_str_mv |
Direitos de Autor (c) 2021 ROENTGEN-Revista Científica das Técnicas Radiológicas info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Direitos de Autor (c) 2021 ROENTGEN-Revista Científica das Técnicas Radiológicas |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
NUCLIRAD - Núcleo de Desenvolvimento dos Técnicos de Radiologia |
publisher.none.fl_str_mv |
NUCLIRAD - Núcleo de Desenvolvimento dos Técnicos de Radiologia |
dc.source.none.fl_str_mv |
ROENTGEN-Scientific Journal of Radiological Techniques; Vol. 2 No. 2 (2021): One Profession, different paths; 11-19 ROENTGEN-Revista Científica das Técnicas Radiológicas; v. 2 n. 2 (2021): Uma Profissão, diferentes caminhos; 11-19 2184-7657 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799136439937531904 |