Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index

Detalhes bibliográficos
Autor(a) principal: Stakhiv, O.
Data de Publicação: 2017
Outros Autores: Melo, I., Clarke, M., Aplin, M., Singh, N., Day, K., Dizdarevic, S., Jessop, Maryam, Begley, P., Carolino, Elisabete, Vieira, Lina, Sousa, Eva
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.21/8558
Resumo: Este trabalho foi financiado pelo Concurso Anual para Projetos de Investigação, Desenvolvimento, Inovação e Criação Artística (IDI&CA) 2016 do Instituto Politécnico de Lisboa. Código de referência: IPL/2016/CardiaCor_ESTeSL
id RCAP_9ad666962442dec49b8416a982304912
oai_identifier_str oai:repositorio.ipl.pt:10400.21/8558
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass indexMyocardial perfusion imagingComputed tomographyAttenuation correctionObesityBody mass indexIPL/2016/CardiaCor_ESTeSLEste trabalho foi financiado pelo Concurso Anual para Projetos de Investigação, Desenvolvimento, Inovação e Criação Artística (IDI&CA) 2016 do Instituto Politécnico de Lisboa. Código de referência: IPL/2016/CardiaCor_ESTeSLFour groups of 71 subjects 47 with body mass index (BMI) between 30 and 35 (27 Male (M1) and 20 Female (F1)) and 24 with BMI above 35 ( 13 Male (M2) and 11 Female (F2)) who underwent stress-rest , SPECT MPI of a two day protocol, by EANM guideline protocol, with and without the incorporation of the Attenuation correction by computed tomography (CTAC), for stress and rest separately. For perfusion percentage quantifications, the 5 walls model of the left ventricle (LV) was used: anterior (ANT), lateral (LAT), inferior (INF), septal (SEP) and apical (API), using the QGS/QPSTM software. For statistical evaluation, it was used the Friedman test. Statistically significant differences were found in comparison of studies with and without attenuation correction (AC) for: F1 in stress and rest studies respectively for LAT (p=0.006 and p=0.034), INF (p=0.000 and p=0.000) and in rest study for SEP (p=0.044) LV walls; F2 group of stress and rest studies respectively for INF (p=0.001 and p=0.008) walls; M1 group of stress and rest study respectively for LAT (p=0.000 and p=0.000), INF (p=0.000 and p=0.000) SEP (p=0.003 and p=0.001) walls and just in rest study for API (p=0.045) LV walls; M2 group of stress and rest studies respectively for INF (p=0.000 and p=0.000), LAT (p=0.020 and p=0.014) and in stress study for SEP (p=0.003) LV walls. The influence of CT-AC is bigger within the groups with BMI between 30 and 35.APMTACRCIPLStakhiv, O.Melo, I.Clarke, M.Aplin, M.Singh, N.Day, K.Dizdarevic, S.Jessop, MaryamBegley, P.Carolino, ElisabeteVieira, LinaSousa, Eva2018-06-04T17:28:17Z2017-042017-04-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/8558engStakhiv O, Melo I, Clarke M, Carolino E, Vieira L, Sousa E, et al. Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index. In: SYMCOMP 2017, 3rd International Conference on Numerical and Symbolic Computation: developments and applications. APMTAC – Associação Portuguesa de Mecânica Teórica, Aplicada e Computacional; 2017. p. 283-92.978‐989‐99410‐3‐8info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T09:56:08Zoai:repositorio.ipl.pt:10400.21/8558Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:17:18.079135Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index
title Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index
spellingShingle Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index
Stakhiv, O.
Myocardial perfusion imaging
Computed tomography
Attenuation correction
Obesity
Body mass index
IPL/2016/CardiaCor_ESTeSL
title_short Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index
title_full Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index
title_fullStr Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index
title_full_unstemmed Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index
title_sort Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index
author Stakhiv, O.
author_facet Stakhiv, O.
Melo, I.
Clarke, M.
Aplin, M.
Singh, N.
Day, K.
Dizdarevic, S.
Jessop, Maryam
Begley, P.
Carolino, Elisabete
Vieira, Lina
Sousa, Eva
author_role author
author2 Melo, I.
Clarke, M.
Aplin, M.
Singh, N.
Day, K.
Dizdarevic, S.
Jessop, Maryam
Begley, P.
Carolino, Elisabete
Vieira, Lina
Sousa, Eva
author2_role author
author
author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv RCIPL
dc.contributor.author.fl_str_mv Stakhiv, O.
Melo, I.
Clarke, M.
Aplin, M.
Singh, N.
Day, K.
Dizdarevic, S.
Jessop, Maryam
Begley, P.
Carolino, Elisabete
Vieira, Lina
Sousa, Eva
dc.subject.por.fl_str_mv Myocardial perfusion imaging
Computed tomography
Attenuation correction
Obesity
Body mass index
IPL/2016/CardiaCor_ESTeSL
topic Myocardial perfusion imaging
Computed tomography
Attenuation correction
Obesity
Body mass index
IPL/2016/CardiaCor_ESTeSL
description Este trabalho foi financiado pelo Concurso Anual para Projetos de Investigação, Desenvolvimento, Inovação e Criação Artística (IDI&CA) 2016 do Instituto Politécnico de Lisboa. Código de referência: IPL/2016/CardiaCor_ESTeSL
publishDate 2017
dc.date.none.fl_str_mv 2017-04
2017-04-01T00:00:00Z
2018-06-04T17:28:17Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/8558
url http://hdl.handle.net/10400.21/8558
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Stakhiv O, Melo I, Clarke M, Carolino E, Vieira L, Sousa E, et al. Influence of computed tomography attenuation correction in myocardial perfusion imaging, in obese patients: classification by sex and body mass index. In: SYMCOMP 2017, 3rd International Conference on Numerical and Symbolic Computation: developments and applications. APMTAC – Associação Portuguesa de Mecânica Teórica, Aplicada e Computacional; 2017. p. 283-92.
978‐989‐99410‐3‐8
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv APMTAC
publisher.none.fl_str_mv APMTAC
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133435153874944