Using 3D anthropometric data for the modelling of customised head immobilisation masks

Detalhes bibliográficos
Autor(a) principal: Loja, MAR
Data de Publicação: 2019
Outros Autores: Sousa, Eva, Vieira, Lina Oliveira, Costa, D. M., Craveiro, D. S., Parafita, R., Costa, D. C.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.21/9996
Resumo: Projeto IPL/2016/SoftImob/ISEL; Projeto IPL/2016/CardiaCor_ESTeSL; Projeto LAETA_UID/EMS/50022/2019.
id RCAP_663d44c5967e963d2a4c0fa47dd99ecd
oai_identifier_str oai:repositorio.ipl.pt:10400.21/9996
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Using 3D anthropometric data for the modelling of customised head immobilisation masks3D surfaces scanningComputed tomographyComputational modelling of head surfaceImmobilisation mask prototypeMask’ mechanical behaviourIPL/2016/SoftImob/ISELIPL/2016/CardiaCor_ESTeSLLAETA_UID/EMS/50022/2019Projeto IPL/2016/SoftImob/ISEL; Projeto IPL/2016/CardiaCor_ESTeSL; Projeto LAETA_UID/EMS/50022/2019.Head immobilization thermoplastic masks for radiotherapy purposes involve a distressful modeling procedure for the patient. To assess the possibility of using different acquisition and reconstruction methods to obtain a 3D skin surface model of PIXY-phantom-head and to present a proposal of an alternative head immobilization mask prototype. Phantom head geometry acquisitions using: computed tomography (reconstructed with ImageJ and Osirix); and 3D Laser Scanner (reconstructed with SolidWorks). From these reconstructed surface models, a set of landmarks was measured and subsequently compared with physical measurements obtained with a Rosscraft-Calliper. For statistical evaluation, relative deviations graphics and Friedman-test for non-parametrical paired samples were used, with a significance level of 5%. For a first assessment of the proposed mask performance, a radiotransparent material was considered, the strength and stiffness evaluation is performed using the finite element method. There are small differences between all the acquisitions and reconstructions methods and the physical measurements, statistically significant differences (X2F(6)) = 6.863, p=0.334) were not found. The proposed mask performed well from the strength and stiffness perspectives, leading to the desired immobilization aim. The immobilization mask design proposal may be an effective alternative to the present completely hand-made situation, which presents a high degree of discomfort and stress to the patients.Taylor & FrancisRCIPLLoja, MARSousa, EvaVieira, Lina OliveiraCosta, D. M.Craveiro, D. S.Parafita, R.Costa, D. C.2019-05-14T10:03:24Z2019-042019-04-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/9996engLoja MAR, Sousa E, Vieira L, Costa DM, Craveiro DS, parfait R, et al. Using 3D anthropometric data for the modelling of customised head immobilisation masks. Comput Methods Biomech Biomed Eng Imaging Vis. 2019;7(4):428-37.10.1080/21681163.2018.1507840info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T09:59:24Zoai:repositorio.ipl.pt:10400.21/9996Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:18:29.950144Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Using 3D anthropometric data for the modelling of customised head immobilisation masks
title Using 3D anthropometric data for the modelling of customised head immobilisation masks
spellingShingle Using 3D anthropometric data for the modelling of customised head immobilisation masks
Loja, MAR
3D surfaces scanning
Computed tomography
Computational modelling of head surface
Immobilisation mask prototype
Mask’ mechanical behaviour
IPL/2016/SoftImob/ISEL
IPL/2016/CardiaCor_ESTeSL
LAETA_UID/EMS/50022/2019
title_short Using 3D anthropometric data for the modelling of customised head immobilisation masks
title_full Using 3D anthropometric data for the modelling of customised head immobilisation masks
title_fullStr Using 3D anthropometric data for the modelling of customised head immobilisation masks
title_full_unstemmed Using 3D anthropometric data for the modelling of customised head immobilisation masks
title_sort Using 3D anthropometric data for the modelling of customised head immobilisation masks
author Loja, MAR
author_facet Loja, MAR
Sousa, Eva
Vieira, Lina Oliveira
Costa, D. M.
Craveiro, D. S.
Parafita, R.
Costa, D. C.
author_role author
author2 Sousa, Eva
Vieira, Lina Oliveira
Costa, D. M.
Craveiro, D. S.
Parafita, R.
Costa, D. C.
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv RCIPL
dc.contributor.author.fl_str_mv Loja, MAR
Sousa, Eva
Vieira, Lina Oliveira
Costa, D. M.
Craveiro, D. S.
Parafita, R.
Costa, D. C.
dc.subject.por.fl_str_mv 3D surfaces scanning
Computed tomography
Computational modelling of head surface
Immobilisation mask prototype
Mask’ mechanical behaviour
IPL/2016/SoftImob/ISEL
IPL/2016/CardiaCor_ESTeSL
LAETA_UID/EMS/50022/2019
topic 3D surfaces scanning
Computed tomography
Computational modelling of head surface
Immobilisation mask prototype
Mask’ mechanical behaviour
IPL/2016/SoftImob/ISEL
IPL/2016/CardiaCor_ESTeSL
LAETA_UID/EMS/50022/2019
description Projeto IPL/2016/SoftImob/ISEL; Projeto IPL/2016/CardiaCor_ESTeSL; Projeto LAETA_UID/EMS/50022/2019.
publishDate 2019
dc.date.none.fl_str_mv 2019-05-14T10:03:24Z
2019-04
2019-04-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/9996
url http://hdl.handle.net/10400.21/9996
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Loja MAR, Sousa E, Vieira L, Costa DM, Craveiro DS, parfait R, et al. Using 3D anthropometric data for the modelling of customised head immobilisation masks. Comput Methods Biomech Biomed Eng Imaging Vis. 2019;7(4):428-37.
10.1080/21681163.2018.1507840
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Taylor & Francis
publisher.none.fl_str_mv Taylor & Francis
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133448984592384