Unusual Solutions for Catheter Placement in Haemodialysis Patients
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.17/2143 |
Resumo: | Background: Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery. |
id |
RCAP_9b5f944062f1ee79e682aa7d38bab74a |
---|---|
oai_identifier_str |
oai:repositorio.chlc.min-saude.pt:10400.17/2143 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Unusual Solutions for Catheter Placement in Haemodialysis PatientsAlternativas na Colocação de Cateteres em HemodiáliseHCC NEFCathetersHemodialysisBackground: Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery.Sociedade Portuguesa de NefrologiaRepositório do Centro Hospitalar Universitário de Lisboa Central, EPECaeiro, FCarvalho, DBrum, SNolasco, F2015-04-29T15:14:35Z20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/2143engPort J Nephrol Hypert 2013; 27 (1): 49-54info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-10T09:35:11Zoai:repositorio.chlc.min-saude.pt:10400.17/2143Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:19:31.794637Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Unusual Solutions for Catheter Placement in Haemodialysis Patients Alternativas na Colocação de Cateteres em Hemodiálise |
title |
Unusual Solutions for Catheter Placement in Haemodialysis Patients |
spellingShingle |
Unusual Solutions for Catheter Placement in Haemodialysis Patients Caeiro, F HCC NEF Catheters Hemodialysis |
title_short |
Unusual Solutions for Catheter Placement in Haemodialysis Patients |
title_full |
Unusual Solutions for Catheter Placement in Haemodialysis Patients |
title_fullStr |
Unusual Solutions for Catheter Placement in Haemodialysis Patients |
title_full_unstemmed |
Unusual Solutions for Catheter Placement in Haemodialysis Patients |
title_sort |
Unusual Solutions for Catheter Placement in Haemodialysis Patients |
author |
Caeiro, F |
author_facet |
Caeiro, F Carvalho, D Brum, S Nolasco, F |
author_role |
author |
author2 |
Carvalho, D Brum, S Nolasco, F |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Repositório do Centro Hospitalar Universitário de Lisboa Central, EPE |
dc.contributor.author.fl_str_mv |
Caeiro, F Carvalho, D Brum, S Nolasco, F |
dc.subject.por.fl_str_mv |
HCC NEF Catheters Hemodialysis |
topic |
HCC NEF Catheters Hemodialysis |
description |
Background: Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013 2013-01-01T00:00:00Z 2015-04-29T15:14:35Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.17/2143 |
url |
http://hdl.handle.net/10400.17/2143 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Port J Nephrol Hypert 2013; 27 (1): 49-54 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Nefrologia |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Nefrologia |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799131292174909440 |