Unusual solutions for catheter placement in haemodialysis patients

Detalhes bibliográficos
Autor(a) principal: Caeiro,Fernando
Data de Publicação: 2013
Outros Autores: Carvalho,Dulce, Brum,Sandra, Nolasco,Fernando
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008
Resumo: Background:Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery.
id RCAP_8c7dfc30e1d7c7c8acd22a99034909cc
oai_identifier_str oai:scielo:S0872-01692013000100008
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Unusual solutions for catheter placement in haemodialysis patientsCathetershaemodialysisvascular access failureBackground:Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery.Sociedade Portuguesa de Nefrologia2013-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008Portuguese Journal of Nephrology & Hypertension v.27 n.1 2013reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008Caeiro,FernandoCarvalho,DulceBrum,SandraNolasco,Fernandoinfo:eu-repo/semantics/openAccess2024-02-06T17:04:41Zoai:scielo:S0872-01692013000100008Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:18:50.119304Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Unusual solutions for catheter placement in haemodialysis patients
title Unusual solutions for catheter placement in haemodialysis patients
spellingShingle Unusual solutions for catheter placement in haemodialysis patients
Caeiro,Fernando
Catheters
haemodialysis
vascular access failure
title_short Unusual solutions for catheter placement in haemodialysis patients
title_full Unusual solutions for catheter placement in haemodialysis patients
title_fullStr Unusual solutions for catheter placement in haemodialysis patients
title_full_unstemmed Unusual solutions for catheter placement in haemodialysis patients
title_sort Unusual solutions for catheter placement in haemodialysis patients
author Caeiro,Fernando
author_facet Caeiro,Fernando
Carvalho,Dulce
Brum,Sandra
Nolasco,Fernando
author_role author
author2 Carvalho,Dulce
Brum,Sandra
Nolasco,Fernando
author2_role author
author
author
dc.contributor.author.fl_str_mv Caeiro,Fernando
Carvalho,Dulce
Brum,Sandra
Nolasco,Fernando
dc.subject.por.fl_str_mv Catheters
haemodialysis
vascular access failure
topic Catheters
haemodialysis
vascular access failure
description Background:Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery.
publishDate 2013
dc.date.none.fl_str_mv 2013-01-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008
url http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Nefrologia
publisher.none.fl_str_mv Sociedade Portuguesa de Nefrologia
dc.source.none.fl_str_mv Portuguese Journal of Nephrology & Hypertension v.27 n.1 2013
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137278349541376