A new sampling device for measuring solids hold-up in a three-phase system

Detalhes bibliográficos
Autor(a) principal: Freitas, Carla Maria Duarte de
Data de Publicação: 1997
Outros Autores: Vicente, A. A., Mota, M., Teixeira, J. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/1638
Resumo: Measurement of solids hold-up in gas-liquid-solid systems was achieved by using a cylinder with a valve in each extremity, which allowed direct sampling inside the reactor causing minimal disturbances to the fluid flow. The method was developed and tested in a 60 L concentric draught tube airlift reactor. Validation of the method was done by means of an overall balance to the solid phase in the bioreactor.
id RCAP_a48aa9ff35c44deb5fecba59b33e61dc
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/1638
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling A new sampling device for measuring solids hold-up in a three-phase systemScience & TechnologyMeasurement of solids hold-up in gas-liquid-solid systems was achieved by using a cylinder with a valve in each extremity, which allowed direct sampling inside the reactor causing minimal disturbances to the fluid flow. The method was developed and tested in a 60 L concentric draught tube airlift reactor. Validation of the method was done by means of an overall balance to the solid phase in the bioreactor.Junta Nacional de Investigação Científica e Tecnológica (JNICT).Fundação para a Ciência e a Tecnologia (FCT) - PRAXIS XXI//BM/1500/94.Chapman & HallUniversidade do MinhoFreitas, Carla Maria Duarte deVicente, A. A.Mota, M.Teixeira, J. A.1997-071997-07-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/1638eng"Biotechnology techniques". ISSN 0951-208X. 11:7 (1997) 489-492.0951-208X10.1023/A:1018405931310The original publication is available at www.springerlink.cominfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:48:30Zoai:repositorium.sdum.uminho.pt:1822/1638Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:46:45.820858Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv A new sampling device for measuring solids hold-up in a three-phase system
title A new sampling device for measuring solids hold-up in a three-phase system
spellingShingle A new sampling device for measuring solids hold-up in a three-phase system
Freitas, Carla Maria Duarte de
Science & Technology
title_short A new sampling device for measuring solids hold-up in a three-phase system
title_full A new sampling device for measuring solids hold-up in a three-phase system
title_fullStr A new sampling device for measuring solids hold-up in a three-phase system
title_full_unstemmed A new sampling device for measuring solids hold-up in a three-phase system
title_sort A new sampling device for measuring solids hold-up in a three-phase system
author Freitas, Carla Maria Duarte de
author_facet Freitas, Carla Maria Duarte de
Vicente, A. A.
Mota, M.
Teixeira, J. A.
author_role author
author2 Vicente, A. A.
Mota, M.
Teixeira, J. A.
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Freitas, Carla Maria Duarte de
Vicente, A. A.
Mota, M.
Teixeira, J. A.
dc.subject.por.fl_str_mv Science & Technology
topic Science & Technology
description Measurement of solids hold-up in gas-liquid-solid systems was achieved by using a cylinder with a valve in each extremity, which allowed direct sampling inside the reactor causing minimal disturbances to the fluid flow. The method was developed and tested in a 60 L concentric draught tube airlift reactor. Validation of the method was done by means of an overall balance to the solid phase in the bioreactor.
publishDate 1997
dc.date.none.fl_str_mv 1997-07
1997-07-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/1638
url http://hdl.handle.net/1822/1638
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv "Biotechnology techniques". ISSN 0951-208X. 11:7 (1997) 489-492.
0951-208X
10.1023/A:1018405931310
The original publication is available at www.springerlink.com
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Chapman & Hall
publisher.none.fl_str_mv Chapman & Hall
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133037312606208