Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples

Detalhes bibliográficos
Autor(a) principal: Zagalo, Paulo M.
Data de Publicação: 2022
Outros Autores: Ribeiro, Paulo A., Raposo, Maria
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10362/143187
Resumo: PD/00193/2012
id RCAP_ac1d73f8e560688df48e0d6630caab37
oai_identifier_str oai:run.unl.pt:10362/143187
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samplesapplied voltageEE2impedanceinterdigitated electrodeslayer-by-layersensorsthin filmsAnalytical ChemistryPhysical and Theoretical ChemistryPD/00193/2012The effect of impedance measurements of applied voltage on the detection of 17α-ethiny lestradiol (EE2) in water samples using interdigitated electrodes (IDE) coated or not with thin films, is described. Firstly, the effect of immersion in EE2 aqueous solutions of layer-by-layer films prepared with poly(allylamine hydrochloride) (PAH), graphene oxide (GO), poly(1-(4-(3-carboxy-4-hydroxyphenylazo) benzene sulfonamido) 1,2 ethanediyl, sodium salt) (PAZO), polyethylenimine (PEI) and poly(sodium 4-styrenesulfonate) (PSS) was analyzed. These results demonstrated that PAH/GO films desorb during the immersion on EE2 solutions, while EE2 adsorbs on PAH/PAZO and PEI/PSS films with characteristic time values of 16.7 and 7.1 min, respectively, demonstrating that both films are adequate for the development of EE2 sensors. However, as the adsorption characteristic time is shorter, and the EE2 adsorbed amount is smaller, the PEI/PSS films are more suitable for the development of sensors. The effect of the applied voltage was analyzed using both IDEs covered with PEI/PSS films as well as those uncoated. The capacitance spectra are best fitted to analyze this effect, and the loss tangent spectra are advantageous to analyze the aqueous media. Furthermore, it was concluded that lower voltage values are best suited to perform measurements of this nature, given that higher voltages lead to less reliable results and cause irreparable damage to the sensors.CeFITec – Centro de Física e Investigação TecnológicaDF – Departamento de FísicaLIBPhys-UNLRUNZagalo, Paulo M.Ribeiro, Paulo A.Raposo, Maria2022-08-22T22:16:21Z2022-03-162022-03-16T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article13application/pdfhttp://hdl.handle.net/10362/143187eng2227-9040PURE: 43545000https://doi.org/10.3390/chemosensors10030114info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-11T05:21:21Zoai:run.unl.pt:10362/143187Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:50:44.719942Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
title Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
spellingShingle Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
Zagalo, Paulo M.
applied voltage
EE2
impedance
interdigitated electrodes
layer-by-layer
sensors
thin films
Analytical Chemistry
Physical and Theoretical Chemistry
title_short Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
title_full Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
title_fullStr Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
title_full_unstemmed Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
title_sort Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
author Zagalo, Paulo M.
author_facet Zagalo, Paulo M.
Ribeiro, Paulo A.
Raposo, Maria
author_role author
author2 Ribeiro, Paulo A.
Raposo, Maria
author2_role author
author
dc.contributor.none.fl_str_mv CeFITec – Centro de Física e Investigação Tecnológica
DF – Departamento de Física
LIBPhys-UNL
RUN
dc.contributor.author.fl_str_mv Zagalo, Paulo M.
Ribeiro, Paulo A.
Raposo, Maria
dc.subject.por.fl_str_mv applied voltage
EE2
impedance
interdigitated electrodes
layer-by-layer
sensors
thin films
Analytical Chemistry
Physical and Theoretical Chemistry
topic applied voltage
EE2
impedance
interdigitated electrodes
layer-by-layer
sensors
thin films
Analytical Chemistry
Physical and Theoretical Chemistry
description PD/00193/2012
publishDate 2022
dc.date.none.fl_str_mv 2022-08-22T22:16:21Z
2022-03-16
2022-03-16T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10362/143187
url http://hdl.handle.net/10362/143187
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2227-9040
PURE: 43545000
https://doi.org/10.3390/chemosensors10030114
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 13
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799138103320903680