Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10362/143187 |
Resumo: | PD/00193/2012 |
id |
RCAP_ac1d73f8e560688df48e0d6630caab37 |
---|---|
oai_identifier_str |
oai:run.unl.pt:10362/143187 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samplesapplied voltageEE2impedanceinterdigitated electrodeslayer-by-layersensorsthin filmsAnalytical ChemistryPhysical and Theoretical ChemistryPD/00193/2012The effect of impedance measurements of applied voltage on the detection of 17α-ethiny lestradiol (EE2) in water samples using interdigitated electrodes (IDE) coated or not with thin films, is described. Firstly, the effect of immersion in EE2 aqueous solutions of layer-by-layer films prepared with poly(allylamine hydrochloride) (PAH), graphene oxide (GO), poly(1-(4-(3-carboxy-4-hydroxyphenylazo) benzene sulfonamido) 1,2 ethanediyl, sodium salt) (PAZO), polyethylenimine (PEI) and poly(sodium 4-styrenesulfonate) (PSS) was analyzed. These results demonstrated that PAH/GO films desorb during the immersion on EE2 solutions, while EE2 adsorbs on PAH/PAZO and PEI/PSS films with characteristic time values of 16.7 and 7.1 min, respectively, demonstrating that both films are adequate for the development of EE2 sensors. However, as the adsorption characteristic time is shorter, and the EE2 adsorbed amount is smaller, the PEI/PSS films are more suitable for the development of sensors. The effect of the applied voltage was analyzed using both IDEs covered with PEI/PSS films as well as those uncoated. The capacitance spectra are best fitted to analyze this effect, and the loss tangent spectra are advantageous to analyze the aqueous media. Furthermore, it was concluded that lower voltage values are best suited to perform measurements of this nature, given that higher voltages lead to less reliable results and cause irreparable damage to the sensors.CeFITec – Centro de Física e Investigação TecnológicaDF – Departamento de FísicaLIBPhys-UNLRUNZagalo, Paulo M.Ribeiro, Paulo A.Raposo, Maria2022-08-22T22:16:21Z2022-03-162022-03-16T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article13application/pdfhttp://hdl.handle.net/10362/143187eng2227-9040PURE: 43545000https://doi.org/10.3390/chemosensors10030114info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-11T05:21:21Zoai:run.unl.pt:10362/143187Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:50:44.719942Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples |
title |
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples |
spellingShingle |
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples Zagalo, Paulo M. applied voltage EE2 impedance interdigitated electrodes layer-by-layer sensors thin films Analytical Chemistry Physical and Theoretical Chemistry |
title_short |
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples |
title_full |
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples |
title_fullStr |
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples |
title_full_unstemmed |
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples |
title_sort |
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples |
author |
Zagalo, Paulo M. |
author_facet |
Zagalo, Paulo M. Ribeiro, Paulo A. Raposo, Maria |
author_role |
author |
author2 |
Ribeiro, Paulo A. Raposo, Maria |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
CeFITec – Centro de Física e Investigação Tecnológica DF – Departamento de Física LIBPhys-UNL RUN |
dc.contributor.author.fl_str_mv |
Zagalo, Paulo M. Ribeiro, Paulo A. Raposo, Maria |
dc.subject.por.fl_str_mv |
applied voltage EE2 impedance interdigitated electrodes layer-by-layer sensors thin films Analytical Chemistry Physical and Theoretical Chemistry |
topic |
applied voltage EE2 impedance interdigitated electrodes layer-by-layer sensors thin films Analytical Chemistry Physical and Theoretical Chemistry |
description |
PD/00193/2012 |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-08-22T22:16:21Z 2022-03-16 2022-03-16T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10362/143187 |
url |
http://hdl.handle.net/10362/143187 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2227-9040 PURE: 43545000 https://doi.org/10.3390/chemosensors10030114 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
13 application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799138103320903680 |