Flat slab strenghtening techniques against punching-shear

Detalhes bibliográficos
Autor(a) principal: Lapi, Massimo
Data de Publicação: 2019
Outros Autores: Ramos, António Pinho, Orlando, Maurizio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxK
Resumo: Over the years, the flat slab system has become a popular form of construction in many countries, particularly for multi-storey buildings such as offices or carparks. Nowadays, a considerable number of flat slab buildings requires strengthening against punching. Reasons are several, like design or construction errors, poor quality materials, not complying with new codes provisions, or increase of vertical load. This paper discusses different techniques for strengthening of R/C slabs against punching: insertion of post-installed shear reinforcement, application of external fibre reinforced polymers or a bonded reinforced concrete overlay (BRCO) on the slab top surface, enlargement of the support, application of a post-tensioning system. The authors propose a unified approach, based on the Critical Shear Crack Theory (CSCT), to evaluate the effectiveness of each strengthening technique. The attempt is to give a reading key capable of adapting to different strengthening techniques and providing a comprehensive view of the problem. The study shows that the CSCT could be easily adapted to all strengthening techniques and punching strength predictions are in good agreement with literature experimental results. This work also proposes to give designers the tool to choose which strengthening technique suits better to the specific case.
id RCAP_ad125e1ea8addf5e39249d82288c511d
oai_identifier_str oai:run.unl.pt:10362/80890
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Flat slab strenghtening techniques against punching-shearBRCOCSCTFRPPost-installed shear reinforcementPost-tensioningPunching strengtheningSupport enlargementCivil and Structural EngineeringOver the years, the flat slab system has become a popular form of construction in many countries, particularly for multi-storey buildings such as offices or carparks. Nowadays, a considerable number of flat slab buildings requires strengthening against punching. Reasons are several, like design or construction errors, poor quality materials, not complying with new codes provisions, or increase of vertical load. This paper discusses different techniques for strengthening of R/C slabs against punching: insertion of post-installed shear reinforcement, application of external fibre reinforced polymers or a bonded reinforced concrete overlay (BRCO) on the slab top surface, enlargement of the support, application of a post-tensioning system. The authors propose a unified approach, based on the Critical Shear Crack Theory (CSCT), to evaluate the effectiveness of each strengthening technique. The attempt is to give a reading key capable of adapting to different strengthening techniques and providing a comprehensive view of the problem. The study shows that the CSCT could be easily adapted to all strengthening techniques and punching strength predictions are in good agreement with literature experimental results. This work also proposes to give designers the tool to choose which strengthening technique suits better to the specific case.CERIS - Polo NOVADEC - Departamento de Engenharia CivilRUNLapi, MassimoRamos, António PinhoOrlando, Maurizio2019-09-11T22:30:52Z2019-02-012019-02-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article21application/pdfhttp://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxKeng0141-0296PURE: 10828383http://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxKinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-11T04:35:49Zoai:run.unl.pt:10362/80890Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:35:57.654052Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Flat slab strenghtening techniques against punching-shear
title Flat slab strenghtening techniques against punching-shear
spellingShingle Flat slab strenghtening techniques against punching-shear
Lapi, Massimo
BRCO
CSCT
FRP
Post-installed shear reinforcement
Post-tensioning
Punching strengthening
Support enlargement
Civil and Structural Engineering
title_short Flat slab strenghtening techniques against punching-shear
title_full Flat slab strenghtening techniques against punching-shear
title_fullStr Flat slab strenghtening techniques against punching-shear
title_full_unstemmed Flat slab strenghtening techniques against punching-shear
title_sort Flat slab strenghtening techniques against punching-shear
author Lapi, Massimo
author_facet Lapi, Massimo
Ramos, António Pinho
Orlando, Maurizio
author_role author
author2 Ramos, António Pinho
Orlando, Maurizio
author2_role author
author
dc.contributor.none.fl_str_mv CERIS - Polo NOVA
DEC - Departamento de Engenharia Civil
RUN
dc.contributor.author.fl_str_mv Lapi, Massimo
Ramos, António Pinho
Orlando, Maurizio
dc.subject.por.fl_str_mv BRCO
CSCT
FRP
Post-installed shear reinforcement
Post-tensioning
Punching strengthening
Support enlargement
Civil and Structural Engineering
topic BRCO
CSCT
FRP
Post-installed shear reinforcement
Post-tensioning
Punching strengthening
Support enlargement
Civil and Structural Engineering
description Over the years, the flat slab system has become a popular form of construction in many countries, particularly for multi-storey buildings such as offices or carparks. Nowadays, a considerable number of flat slab buildings requires strengthening against punching. Reasons are several, like design or construction errors, poor quality materials, not complying with new codes provisions, or increase of vertical load. This paper discusses different techniques for strengthening of R/C slabs against punching: insertion of post-installed shear reinforcement, application of external fibre reinforced polymers or a bonded reinforced concrete overlay (BRCO) on the slab top surface, enlargement of the support, application of a post-tensioning system. The authors propose a unified approach, based on the Critical Shear Crack Theory (CSCT), to evaluate the effectiveness of each strengthening technique. The attempt is to give a reading key capable of adapting to different strengthening techniques and providing a comprehensive view of the problem. The study shows that the CSCT could be easily adapted to all strengthening techniques and punching strength predictions are in good agreement with literature experimental results. This work also proposes to give designers the tool to choose which strengthening technique suits better to the specific case.
publishDate 2019
dc.date.none.fl_str_mv 2019-09-11T22:30:52Z
2019-02-01
2019-02-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxK
url http://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxK
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0141-0296
PURE: 10828383
http://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxK
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 21
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137979682258944