Resumo: | Over the years, the flat slab system has become a popular form of construction in many countries, particularly for multi-storey buildings such as offices or carparks. Nowadays, a considerable number of flat slab buildings requires strengthening against punching. Reasons are several, like design or construction errors, poor quality materials, not complying with new codes provisions, or increase of vertical load. This paper discusses different techniques for strengthening of R/C slabs against punching: insertion of post-installed shear reinforcement, application of external fibre reinforced polymers or a bonded reinforced concrete overlay (BRCO) on the slab top surface, enlargement of the support, application of a post-tensioning system. The authors propose a unified approach, based on the Critical Shear Crack Theory (CSCT), to evaluate the effectiveness of each strengthening technique. The attempt is to give a reading key capable of adapting to different strengthening techniques and providing a comprehensive view of the problem. The study shows that the CSCT could be easily adapted to all strengthening techniques and punching strength predictions are in good agreement with literature experimental results. This work also proposes to give designers the tool to choose which strengthening technique suits better to the specific case. |
id |
RCAP_ad125e1ea8addf5e39249d82288c511d |
---|---|
oai_identifier_str |
oai:run.unl.pt:10362/80890 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Flat slab strenghtening techniques against punching-shearBRCOCSCTFRPPost-installed shear reinforcementPost-tensioningPunching strengtheningSupport enlargementCivil and Structural EngineeringOver the years, the flat slab system has become a popular form of construction in many countries, particularly for multi-storey buildings such as offices or carparks. Nowadays, a considerable number of flat slab buildings requires strengthening against punching. Reasons are several, like design or construction errors, poor quality materials, not complying with new codes provisions, or increase of vertical load. This paper discusses different techniques for strengthening of R/C slabs against punching: insertion of post-installed shear reinforcement, application of external fibre reinforced polymers or a bonded reinforced concrete overlay (BRCO) on the slab top surface, enlargement of the support, application of a post-tensioning system. The authors propose a unified approach, based on the Critical Shear Crack Theory (CSCT), to evaluate the effectiveness of each strengthening technique. The attempt is to give a reading key capable of adapting to different strengthening techniques and providing a comprehensive view of the problem. The study shows that the CSCT could be easily adapted to all strengthening techniques and punching strength predictions are in good agreement with literature experimental results. This work also proposes to give designers the tool to choose which strengthening technique suits better to the specific case.CERIS - Polo NOVADEC - Departamento de Engenharia CivilRUNLapi, MassimoRamos, António PinhoOrlando, Maurizio2019-09-11T22:30:52Z2019-02-012019-02-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article21application/pdfhttp://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxKeng0141-0296PURE: 10828383http://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxKinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-11T04:35:49Zoai:run.unl.pt:10362/80890Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:35:57.654052Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Flat slab strenghtening techniques against punching-shear |
title |
Flat slab strenghtening techniques against punching-shear |
spellingShingle |
Flat slab strenghtening techniques against punching-shear Lapi, Massimo BRCO CSCT FRP Post-installed shear reinforcement Post-tensioning Punching strengthening Support enlargement Civil and Structural Engineering |
title_short |
Flat slab strenghtening techniques against punching-shear |
title_full |
Flat slab strenghtening techniques against punching-shear |
title_fullStr |
Flat slab strenghtening techniques against punching-shear |
title_full_unstemmed |
Flat slab strenghtening techniques against punching-shear |
title_sort |
Flat slab strenghtening techniques against punching-shear |
author |
Lapi, Massimo |
author_facet |
Lapi, Massimo Ramos, António Pinho Orlando, Maurizio |
author_role |
author |
author2 |
Ramos, António Pinho Orlando, Maurizio |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
CERIS - Polo NOVA DEC - Departamento de Engenharia Civil RUN |
dc.contributor.author.fl_str_mv |
Lapi, Massimo Ramos, António Pinho Orlando, Maurizio |
dc.subject.por.fl_str_mv |
BRCO CSCT FRP Post-installed shear reinforcement Post-tensioning Punching strengthening Support enlargement Civil and Structural Engineering |
topic |
BRCO CSCT FRP Post-installed shear reinforcement Post-tensioning Punching strengthening Support enlargement Civil and Structural Engineering |
description |
Over the years, the flat slab system has become a popular form of construction in many countries, particularly for multi-storey buildings such as offices or carparks. Nowadays, a considerable number of flat slab buildings requires strengthening against punching. Reasons are several, like design or construction errors, poor quality materials, not complying with new codes provisions, or increase of vertical load. This paper discusses different techniques for strengthening of R/C slabs against punching: insertion of post-installed shear reinforcement, application of external fibre reinforced polymers or a bonded reinforced concrete overlay (BRCO) on the slab top surface, enlargement of the support, application of a post-tensioning system. The authors propose a unified approach, based on the Critical Shear Crack Theory (CSCT), to evaluate the effectiveness of each strengthening technique. The attempt is to give a reading key capable of adapting to different strengthening techniques and providing a comprehensive view of the problem. The study shows that the CSCT could be easily adapted to all strengthening techniques and punching strength predictions are in good agreement with literature experimental results. This work also proposes to give designers the tool to choose which strengthening technique suits better to the specific case. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-09-11T22:30:52Z 2019-02-01 2019-02-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxK |
url |
http://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxK |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
0141-0296 PURE: 10828383 http://www.scopus.com/inward/record.url?scp=85056773544&partnerID=8YFLogxK |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
21 application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137979682258944 |